My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7209 6TH AVE W 2025-12-12
>
Address Records
>
6TH AVE W
>
7209
>
7209 6TH AVE W 2025-12-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2025 11:40:57 AM
Creation date
10/22/2025 1:38:50 PM
Metadata
Fields
Template:
Address Document
Street Name
6TH AVE W
Street Number
7209
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK ALL APPLICABLE BOXES;MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE <br /> RESIDENT BEDROOM DESIGNATIONS OF A 8 C D E AND F AND CLASSIFICATION CODE S,NSi OR NS2. <br /> • 0 ! • • • ' • <br /> R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. <br /> Type NS1-where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R330.9 Is provided to evacuate <br /> residents to public area. <br /> Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R330.9 are provided to <br /> evacuate residents to public area. <br /> SLEEPING ROOM A IF3Type S Type NS1 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ®Yes Q Na ®N/A I Smoke alarm is installed in the bedroom 13 <br /> Bedroom door opens easily and quickly from the outside when locked 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed <br /> SLEEPING ROOM B 1 E3 Type S Type NS1 JE3 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside Q Yes Q No ®N/A I Smoke alarm is installed in the bedroom 13 <br /> Bedroom door opens easily and quickly from the outside when locked 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed iP 13 <br /> SLEEPING ROOM C 10 Type S I q Type NS1 10 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ®Yes ®Na ®N/A I Smoke alarm is installed In the bedroom <br /> Bedroom door opens easily and quickly from the outside when locked 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed <br /> SLEEPING ROOM D Type S Type NSi ®Type NS2 YE NO <br /> Closet door/s are readily openable from the inside 113 Yes ®No I®N/A I Smoke alarm is installed in the bedroom 13 <br /> Bedroom door opens easily and quickly from the outside when locked <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed <br /> SLEEPING ROOM E ILIType 5 Type NS-1 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 113 Yes 113No QN/A I Smoke alarm is installed in the bedroom <br /> Bedroom door opens easily and quickly from the outside when locked 13 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) IM <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed <br /> SLEEPING ROOM F I E3 Type S I PType NS1 TETType NS2 YES NO <br /> Closet door/s are readily openable from the inside ®Yes JE3 No I®N/A I Smoke alarm is installed In the bedroom El 13 <br /> Bedroom door opens easily and quickly from the outside when locked <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 13 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed d <br /> Implementation Date:2021 February 01 <br /> Updated: 2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.