Joey Design LLC <br /> 7209 61h Avenue <br /> B2401-012 <br /> a. Itemized letter addressing the comments provided below. <br /> b. Two complete sets of revised construction drawings, cloud all revised parts. <br /> c. Two copies of supplemental structural calculations (if applicable). <br /> Submittal documents should contain sufficient information and detail to review the proposed project <br /> for compliance with the adopted building codes. Upon submittal of the revised documents, your <br /> application will be given priority and the review will recommence. <br /> General <br /> 1. This review is for compliance to the IRC. Owner is responsible for compliance with other <br /> AFH requirements. AFH Section R330 referenced herein refers to WAC-51-0330, part of <br /> WAC 51-51 State Building Code adoption and amendments. (WAC 51-51) <br /> 2. Historical photos shows accessory structures in the back yard. Please indicate if these are <br /> existing structures to remain or to be removed. If to remain, please show on the site plan <br /> and include horizontal dimensions, size and distance to property lines. Any structures larger <br /> than 200 square feet require a permit. Include this structure in your permit application if <br /> larger than 200 square feet. (IRC 105.2) <br /> 3. Mechanical, Plumbing and Electrical permits are required. Please refer to the following <br /> website link for applications and/or checklists. Permit Applications, submittal checklists, &fee <br /> schedules I Everett, WA-Official Website (everettwa.gov) <br /> Energy— Sheet A2 <br /> 1. Please select either"Yes"or"No"on the WSEC form to the far left of the sheet. <br /> 2. Please show ventilation exhaust systems in the plans for the toilet rooms, laundry and <br /> kitchen, and that the exhaust vents on the exterior are at least 3 feet away from any <br /> openings into the building. <br /> 3. Provide information on existing furnace that indicates how current furnace meets current <br /> code (IRC 505) <br /> 4. Please show on the plans where the existing furnace exhaust exits the building, and that it <br /> is at least 10 feet away from any openings into the building (windows). <br /> 5. Furnace room on main floor. Please add a note indicating the interior of the room is <br /> completely sealed with 1/2" gyp bd on walls and ceiling interior of closet. Provide <br /> fireblocking at penetrations (IRC 302.11) <br /> Architectural <br /> 1. Foam plastics should be protected and meet flame spread <75 and smoke development <br /> requirements <450. On detail 2/A4, please show 1/2"gyp board concealing exposed R-5 <br /> insulation on curb. (IRC 316.3, IRC 316.4) <br /> 2. It appears that some of the existing windows in proposed bedrooms do not meet the sill <br /> height requirement of maximum 44"AFF. Please confirm and add notes to floor plans, or <br /> provide windows that comply. (IRC R310.2.3). <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />