Laserfiche WebLink
Existing lot coverage by building must be confirmed by applicant and must include ALL existing buildings, even storage sheds, and shall be shown on site plan. <br /> If deck located at 1617 provides a weathertight roof for parking below it must be calculated in lot coverage. <br /> "Lot coverage by building" means the amount or percent of the ground area of a lot on which buildings are located. This amount/percent includes all areas which are partially or totally enclosed and <br /> covered by a weathertight roof, including any garages, carports, and cantilevered portions of a building which are not above the ground floor of a building, and storage areas covered by a watertight <br /> roof even if not fully enclosed. Building coverage does not include eaves, decks, and uncovered porches. <br /> Property corner marker <br /> is in wrong spot. �= WATER �N <br /> SEWER ...e. <br /> stairs&Ian ing z �_ �� <br /> 11 6 - 3,600 sq. ft. <br /> -j 32-0" <br /> 75' X <br /> � sta rs I ' � - - 20' - 9, 00 1 t <br /> 101-011 <br /> 20'-0" -rZ �sri,tG s2 1613 = 914 (?) sq. ft. <br /> 1615 = 828 (?) sq. ft. <br /> o1. ;1617 <br /> 3,� > 1617 = 1,032 (?) sq. ft. <br /> 7 equals = 78-6 s- :. -rv*-�� ,A=V#N — I" but lot is only _ proposed = 720 sq. ft. <br /> V Show �I 75'-0" wide. tY �p�aULICO s� �'�`� total 3,494 (?) sq. ft. <br /> E 'JN —� - z stairs - - - - - '-.�- - - -i Revise 2c,S�"rrs �� -►-t�,� _' o <br /> � 8'CONCRETE DR VEWAY I�2' 1 3,494 / 9,000 = 38.82/o <br /> - - - - to deck I accordingly 2 ;— t�� 'r< 387 <br /> Confirm calculations and <br /> va W/-y revise Lot Coverage by <br /> �rl i t.,. B �; ;-�czosa -- Buildn calculations. - - <br /> ---- - - _ <br /> j - s . <br /> 1�y of q- ,0 iTOT7h� '�'.�3(o LU <br /> N <br /> 1613 I Y''��i Sr c� C ��RC�osPi <br /> �rlA.� ¢m <br /> _i_ _ _ _ _�_�_d_ _ _`� ; Existing impervious surface calculations must M M <br /> i <br /> include calculations for entire 75' x 120' lot. co a <br /> �-/ °pr'� Pt" F- <br /> NQ <br /> 0Show proposed Location 3 z <br /> exterior stairs and A r = Location of proposed ,�� v.Lots 7, 8, and 9, Block 337, Plat of Everett, Division N AM <br /> 77 0. <br /> s 'C - - garage may be over thezG. t� «�:es�:� a� !z1�h►�2 �v�zrr� >. 101 Q <br /> landing to upper e ,L: coM��omtc4tum ju�•r ± °sc�u 3;,3u ,a-iceo asta*sc. <br /> to of 1613's water line. <br /> floor. Must be p �-t�� -� �r.t nts� , ,$.-r� 2ooc9o�o�ocow4 <br /> drawn to scale with _.. �, ; _ ..� ;` � 1. - �s�� u� � -z �z �� oro • ,� ;. � �s��. <br /> dimensions labeled. _. -_CWJ/ <br /> Property corners HEIGHT CALCULATIONS <br /> must be surveyed A = Height calculations must <br /> and staked prior to IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO ENSURE B = also be shown on an <br /> construction. COMPLIANCE WITH CONDOMINIUM CONDITIONS & RESTRICTIONS, C = elevation drawing within <br /> AND FOR GETTING OTHER CONDO OWNERS APPROVAL OF D = the plan set showing <br /> PROPOSED GARAGE. Average Base Elevation (ABE) = ABE to the peak of the <br /> Proposed height = roof. <br />