Laserfiche WebLink
SPECIFICATIONS Cabinet Dimensions <br /> • Single PC board design using Surface Mount Technol- Door: 14-3/4" high x 12-3/4"wide <br /> ogy(SMT). (37.465 cm high x 32.385 cm wide). <br /> • Two modular telephone jacks for connection to RJ31X/ Backbox: 14-1/2" high x 12-1/2"wide x 3" deep <br /> Modules. (36.83 cm high x 31.75 cm wide x 7.62 cm <br /> AC Power deep). <br /> • 120 VAC, 50/60 Hz, 0.32 amps. Trim Ring: Part#TR-3-R <br /> • Wire size: minimum 14 AWG with 600-volt insulation. 17-5/8" high x 15-5/8"wide <br /> Built-in brownout circuitry. (44.7675 cm high x 39.6875 cm wide). <br /> • <br /> • Built-in voltmeter. PRODUCT LINE INFORMATION <br /> Communicator Model Description <br /> • One line-active indicator for each of two phone lines. MS-5012 Five-zone, 12-volt Fire Alarm Control Commu- <br /> • "Kiss-Off' signal LED. nicator (includes box & transformer, technical <br /> • Dual low telephone voltage detect circuitry. manual, and a frame& post operating instruc- <br /> • Programmable event codes per each format. tion sheet). <br /> • Up to 40 transmitted events/messages. RZA-51F Five-zone Remote Annunciator mounts to a <br /> • Selectable/Deselectable transmissions of 40 events. single-gang box (requires ADM-12). <br /> • Five zones may be configured to five channels as a slave ADM-12 Annunciator Driver Module. <br /> communicator (channels are auto-resettable). DP-5024 Internal Dress Panel. <br /> Communication Formats MCBL-7 DACT phone cord, 7 feet long (2 required). <br /> • 20 PPS, 3+1 standard and expanded. TR-3-R Trim ring. <br /> • 20 PPS, 4+1 standard and expanded. BAT-1242 Battery, 12 volt,4.2 AH. <br /> • 20 PPS, 4+2 standard and expanded. BAT-1270 Battery, 12 volt,7.0 AH. <br /> Initiating Device Circuits (zones) 5012RB Replacement Mother Board. <br /> The MS-5012 includes five programmable Initiating De- <br /> vice Circuits (zones). Circuits 1, 2, 4, and 5 are Style B <br /> (Class B). Circuit 3 is Style D (Class A). <br /> • Initiating Circuit 1 — Manual Pull Station <br /> • Initiating Circuit 2 — Two-Wire Smoke Detector <br /> • Initiating Circuit 3 — Waterflow <br /> • Initiating Circuit 4 — Supervisory <br /> • Initiating Circuit 5 — Four-Wire Smoke Detector <br /> NOTE: *Default circuit descriptions are listed. Circuits 1, 4, and <br /> 5 may be programmed to monitor any normally open <br /> (N.C.) type of Initiating Device. Circuits 2 & 3 may be <br /> programmed to power two-wire smoke detectors. <br /> All circuits are power limited and fully supervised. They <br /> allow for up to 100 ohms of line resistance and the terminal <br /> blocks allow for 12 to 18 AWG wire. <br /> Notification Appliance Circuits <br /> • One Style Y(Class B) @ 1.0 Amp. <br /> • All circuits are fully power-limited and meet the UL <br /> power-limiting requirements using fuseless technology. <br /> Auxiliary Outputs <br /> • Resettable 4-wire smoke detector power @ 200 mA. <br /> • Non-resettable power @ 185 mA. <br /> • Relay drivers for use with optional remote relays. <br /> Cabinet Specifications <br /> The cabinet is red with a dark blue overlay. Knockouts on <br /> the top, sides and back provide ease of wire entry. The <br /> cabinet also can be surface or semi-flush mounted and is <br /> compact in design. <br /> Page 2 of 3 — DF-51186• 07/12/04 <br />