Laserfiche WebLink
Architect/Engineer Specifications <br /> Smoke detector shall be a System Sensor with a plaster ring,or direct mount to the The detector shall provide dual color LED <br /> i3 Series model number ,listed to ceiling using drywall anchors.Wiring con- indication which blinks to indicate power <br /> Underwriters Laboratories UL 268 for Fire nections shall be made by means of SEMS up,normal standby,out of sensitivity, <br /> Protection Signaling Systems.The detector screws.The detector shall allow pre-wiring alarm,and freeze trouble(model 2WT-B, <br /> shall be a photoelectric type (model 2W-B, of the base and the head shall be a plug- 4WT-B)conditions.When used in conjunc- <br /> 4W-B) or a combination photoelectric/ in type.The detector shall have a nomi- tion with the 2W-MOD2 module,2-wire <br /> thermal (model 2WT-B,4WT-B)with ther- nal sensitivity of 2.5%per foot nominal models shall include a maintenance signal <br /> mal sensor rated at 135°F(57.2°C).The as measured in the UL smoke box.The to indicate the need for maintenance at the <br /> detector shall include a mounting base for detector shall be capable of automatically alarm control panel,and shall provide a <br /> mounting to 3'/z-inch and 4-inch octagonal, adjusting its sensitivity by means of drift loop testing capability to verify the circuit <br /> single gang,and 4-inch square back boxes compensation and smoothing algorithms. without testing each detector individually. <br /> Electrical Specifications <br /> Operating Voltage Standby Current Peak Standby Current <br /> Nominal: 12/24V non-polarized 2-wire: 50 pA maximum average 2-wire: 100 pA <br /> Min.: 8.5V 4-wire: 50 pA maximum average 4-wire: n/a <br /> Max.: 35V <br /> Maximum Alarm Current Alarm Contact Ratings <br /> Maximum Ripple Voltage 2-wire: 130 mA limited by control panel 2-wire: n/a <br /> 30%peak to peak of applied voltage 4-wire: 20 mA @12V, 23mA @ 24V 4-wire:0.5 A @ 30V AC/DC <br /> LED Modes Power Up Sequence for LED Indication <br /> LED Mode Green LED Red LED Condition Duration <br /> Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds <br /> Normal (standby) Blink every 5 seconds off <br /> Out of sensitivity off Blink every 5 seconds <br /> Freeze trouble off Blink every 10 seconds <br /> Alarm off Solid <br /> Physical Specifications <br /> Operating Temperature Range Sensitivity Mounting <br /> 2W-B and 4W-B:327-1207(0°C-49°C) 2.5%/ft.nominal 3�-inch octagonal back box <br /> 2WT-B and 4WT-B:32°F-100°F(O°C-37.80C) 4-inch octagonal back box <br /> Input Terminals Single gang back box <br /> Operating Humidity Range 14-22 AWG <br /> 0 to 95%RH non-condensing 4-inch square back box with a plaster ring <br /> Dimensions(including base) Direct mount to ceiling <br /> Thermal Sensor 5.3 inches(127 mm) diameter <br /> 135°F(57.2°C)fixed 2.0 inches(51 mm) height <br /> Freeze Trouble Weight <br /> 2WT-B and 4WT-B only:41°F(5°C) 6.3 oz.(178 grams) <br /> Ordering Information <br /> Model Thermal Wiring Alarm Current <br /> 2W-B No 2-wire 130 mA max. limited by control panel <br /> 2WT-B Yes 2-wire 130 mA max. limited by control panel <br /> 4W-B No 4-wire 20 mA @ 12V,23mA @ 24V <br /> 4WT-B Yes 4-wire 20 mA @ 12V,23mA @ 24V <br /> Model Description <br /> 2W-MOD2 2-wire loop test/ maintenance module <br /> SENS-RDR Sensitivity reader <br /> RT Removal / replacement tool <br /> A77-AB2 Retrofit adapter bracket, 6.6 in.(16.76cm) diameter <br /> System Sensor Sales and Service <br /> System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor-Far East System Sensor-India <br /> 3825 Ohio Avenue Ph:905.812.0767 Ph:86.29.8832.0119 Ph:85.22.191.9003 Ph:91.124.637.1770 x.2700 <br /> St.Charles, IL 60174 Fx:905.812.0771 Fx:86.29.8832.5110 Fx:85.22.736.6580 Fx:91.124.637.3118 <br /> Ph:800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor-Australia System Sensor-Russia <br /> Fx:630/377-6495 Ph:44.1403.891920 Ph:65.6273.2230 Ph:613.54.281.142 Ph:70.95.937.7982 <br /> www.systemsensor.com Fx:44.1403.891921 Fx:65.6273.2610 Fx:613.54.281.172 Fx: 70.95.937.7983 <br /> @ 2004 System Sensor.The company reserves the right to change product specifications without notice. A05-0318-005.6/04•#1280 <br />