My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5007 CLAREMONT WAY 2025-11-03
>
Address Records
>
CLAREMONT WAY
>
5007
>
5007 CLAREMONT WAY 2025-11-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2025 2:19:15 PM
Creation date
10/29/2025 1:29:55 PM
Metadata
Fields
Template:
Address Document
Street Name
CLAREMONT WAY
Street Number
5007
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A B C D E F G H J K L M N <br /> SITE LOCATION <br /> SYSTEM OUTPUTS <br /> 1 CONTROL"IT NDTInCAnDN sE IeU RE.o`N=DL QUTPUTRLYs 4W I , <br /> A B C D E F G H I J K L M N O P Q R S T U V X Y Z Shaker Church Marysville to <br /> MISSION EACH o - <br /> DEVICE LEGEND SYSTEM INPUT LEGEND ro Priest Point <br /> "BOL DESCPoPTION OTY PARTI MANUFACTOR MOUNTING SPEC s� � �.� r 529 111 HA <br /> / X IF NOR-CONOmoN fig"ozd' o��o�g � � o 9 Lak S1 <br /> �q�`Q <br /> FACP FIRE ALARM CONTROL PANEL PFC6084 POTTER IXISTING •quRm corvolnON T" '��� ,0� ` u ,N ¢ �' NORTHWEST <br /> 2 m"¢y ,g p2 ap b EVERE TT <br /> AES TRANSMITTER Tl0]P-. AES SEE MFG LITERATURE01 <br /> JUNCTION BOX - SYSTEM SENSOR 4'SQUARE DEEP BOX W/COVER h S� P ~�P <br /> 0 WALL TOPOFSTROBELENS@80' SYSTEM INPUTS P a 9 s <br /> M WALL MOUNT STROBE ONLY / SS2415AOA SYSTEM SENSOR TO as'.4-SQUARE W/1G MUDRING <br /> 0eeu1P^°^ A B C D E F G H I J K L M N O P Q R S T U V X Y Z <br /> nn q WALLTOP OF STROBE LENS @ 80' S2 Everett <br /> >21 WALL MOUNT HORN-STROBE / MA552915]5ADA SYSTEMSENSOR TOe6".4-SQUARE W/1GMUDRING SMOKE DETECTION • � 2 Cavalero <br /> WALL MOUNT WEATHERPROOF 1 W 9WT"SQUARE <br /> /SG MU @ 80' <br /> COLUMBIA P T GARDNER <br /> / P2RK SYSTEM SENSOR PULL STATIONS •• • • BEACH � 1 <br /> tt W HORN-STROBE TO88'.4"BQUARE WISG MUDRING y m <br /> 0 WALL @41r 1ST FLOOR ELEVATOR LOBBY SMOKE DETECTOR •. • • . 52 ! B nkFoss <br /> © CONVENTIONAL MANUAL PULL STATION/ 2]o-SPO EDWARDS W/1 GANG MUDRING m <br /> Oj CONVENTIONAL SMOKE DETECTOR 2W-B SYSTEM SENSOR 4-SQUARE DEEP BOX FLOOR ELEvATOR LOBBY SMOKE DETECTOR • • `` Q <br /> W/30 MUDRING •• • • • • 3 <br /> ELEVATOR MACHINE ROOM SMOKE DETECTOR <br /> BOULEVARD ( k <br /> Mukilteo BLUFFS <br /> w <br /> 3 Glendale <br /> Fobes Hill m z <br /> 2 <br /> Boeing Future of Ali 0 52 LL <br /> Possession ¢c`4 <br /> t)[ <br /> SITE LOCATION S <br /> AAA FIRE PROTECTION, INC. AAA FIRE PROTECTION, Inc. <br /> Asbuilt-Requirements 3 ®Jersey Mikes Subs Z <br /> sDndwmll•s o <br /> F <br /> ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING v <br /> DEVICE Q1 STANDBY ALARM TOTALSTAN08 TOT 0L235 M 21 U <br /> 4 PFCli064 1 0.070 o.z35 0.070 o.z35 AAA FIRE PROTECTION INC.WITH ACCURATE REDLINE DRAWINGS. W <br /> CLASS B IMP, <br /> ZONES(PER ZfNJE) 4 0.00500 0.09000 0.0200 0.160 DRAWINGS SHALL BED REDLINED AS NECESSARY TO SHOW THE ry CC~ <br /> ZONE 1 W <br /> 1 ST FLOOR SMOKES 7 0.00005 0.13000 0.0004 0.910 FOLLOWING: 49eM S_L Everett Ace Hardware <br /> 1ST FLOOR PULLS 3 0.00000 0.000W 0.0000 0.000 O Get Gifling�th IZ <br /> ZONE l Ace Herd Were® Q W <br /> 2ND FLOOR SMOKES 2 0.00005 0.13000 0.0001 0.260 ,,¢�� 1% 95 <br /> 2ND FLOOR PULLS 1 0.WOOD 0-Doom 0.OD00 0-Do0 DEVICE LOCATIONS-ADDS/DELETES 0q`r Q Claremont Village L.L. <br /> ZDNE3 CIRCUIT NUMBERS-ADDRESSABLE/SIGNAUZONE/AUXILIARY <br /> SPARE-NOT USED o.00000 0.00000 0.0000 0.00o WIRE/CONDUIT-ACCURATE ROUTINGe�(. r LL <br /> 0.00000 0.00000 0.0000 0.000 Ire O <br /> MINE WIRE FILL-USING WIRE LEGEND � QFL.® U <br /> SPARE-NOT USED 0.00000 0-000ao O.OD00 0-00o EOL-RESISTOR LOCATIONS - Q <br /> 0=o" 0.00000 0.0000 0.000 cc <br /> NOTIFICATION CIRCUTrS a's Childcare Q _ Z <br /> 5 AAA FIRE PROTECTION INC.WILL PROVIDE(UPON REQUEST)A BLANK <br /> NAG CKT.# O•M- STANDBY ALARM WIRE LENGTH TOTAL OHM VD IN CIRCUIT EOL VOLTS VD% 3I O <br /> NAC CKT#1-1ST&2ND FLU 307 0000 0867 o" 5o0 3.07 2.66 21.34 11.1% <br /> SET OF FLOOR PLANS TO BE RECLINED.AAA FIRE PROTECTION,INC. Tropical Tan Of Ever tt C <br /> NAC CKT.#2-SPARE-NOT USED 3.D7 0.000 0.0o0 0 Go, <br /> 00 0.00 24oO o0% WILL INCORPORATE ALL REDLINED CHANGES INTO THE RECORD SET <br /> NAC CKT#3-SPARE-NOT USED 3.07 0.000 0.000 0 0.00 0.00 24.00 0.0% Dollar Tree <br /> OF DRAWINGS. Thrilling Finds O <br /> NAC CKT.#4-SPARE-NOT U So <br /> SED 3.0] 0.000 0.000 0 0.00 0.00 24.00 0.0% at low Prices D <br /> AM POWER 3.07 0.000 0.000 0 0.00 0.00 24.00 0.0% J <br /> A <br /> AUTOCAD ASBUILT COLOR STANDARDS <br /> TOTAL SYSTEM STANDBY 0.090 2432 TOTAL SYSTEM ALARM j. - <br /> d Office supply store - <br /> 24 HOUR STANDBY 2171 0.202 5MIN.ALARM Staples Oth St SE <br /> TOTAL STANDBY+ALARM= 2373 RED-NEW <br /> N <br /> Ao02o%DEBATING 2e47 7.0 AH GREELUE- TE S TO N-DELETEDRAFTERD <br /> HOUR TO BE #I <br /> BNO <br /> B OBATTERY AND VOLTAGE DROP CALCULATIONS <br /> NOT TO SCALE Fire Alarm System Check Off List Q N <br /> For Final Inspection o Do <br /> LU <br /> Following is a list of items that must be completed 4)SCALE: NOT TO SCALE j <br /> VICINTY MAP N <br /> TO CENTRAL ITEMS WITH A LIGHT LINE TYPE OR SHADE g <br /> before the Fire Department will perform a final inspection. U ¢ <br /> � o � <br /> STATION ❑ 1.Low Voltage Electrical Final Completion Date: g O <br /> ARE EXISTING TO REMAIN <br /> ❑2.Line Voltage Electrical Final Completion Date: SCOPE OF WORK <br /> Aes Rnol FACP ❑3.Approved Set of plans and permit on site Completion Date: <br /> REPLACEMENT OF FAILING FIRE ALARM SYSTEM <br /> nD]P- o r r <br /> ❑4.Fire Alarm Monitoring <br /> o ZN-2 ZN-2 zN-2 The scope of this project is to replace a failing 2 zone conventional fire alarm panel <br /> E-2 o Z o P D 2 RE Y EXISTING ZONE 1-1ST FLOOR SMOKES ❑ a Dual Line Communicator completion Date: with a new 4 zone conventional fire alarm panel as a direct replacement in <br /> EOL 4.7K DETECTORS&MANUAL PULL STATIONS EXISTING ZONES <br /> (Phone lines must be installed and active) accordance with the Washington state existing building code level 2 alteration. <br /> NOT CHANGED 9 9 9 ac <br /> EXISTING ZONE 2-2ND FLOOR SMOKES b AES Radio Tranci-r Completion Date: [803.4.1 Exception 1] d <br /> ZN�j-1 ZN-1 ZN-1 ZN-1 ZN-1 ZN-1 ZN-1 ZN-1 ZN-1 ZN-1 DETECTORS&MANUAL PULL STATIONS ❑ P O <br /> EOL 4.71K ❑ C Contract Signed Completion Date: d <br /> aY The existing fire alarm system initiates occupant notification by means of <br /> horn/strobes and strobes upon activation of the smoke detection,and manual pull <br /> B To Oi ---ALTERNATE ELEVATOR RECALL stations.There is a two story elevator with phase 1 and phase 2 elevator recall.This <br /> L I'-a a ------ --------PRIMARYELEVATORRECALL is initiated via relay base smoke detectors at each lobby and machine room. <br /> LINE <br /> Duu <br /> DIALER The fire alarm panel will be replaced and the monitoring changed to transmit via <br /> s1 s1 s1 s1 s1 s1 s1 s1 AES radio.The smoke detection,manual pull stations,horn/strobes,and strobes <br /> 15cd 157150d 15cd 75od 15/75cd 15/75 d 15/75cd 15cd WIRE SCHEDULE <br /> GENERALALARMTOAES R1 RLY1 NAC1 S1 B EXISTING CIRCUIT-1ST&2ND FLOORS-CALCULATED are existing as shown.The wiring,Initiation,and signaling devices will remain <br /> 75 B \'21 B 75 B \'58 B '21 B B 75 AT FIELD CURRENT READING_867_EXISTING CODE DESCRIPTION/FUNCTION unchanged and reconnect to the new direct replacement panel. <br /> .0]SmA .121mA .075mA .158mA .121mA .121mA .121mA .0]SmA <br /> EOL 4.7K.867A TOTAL CKT CURRENT <br /> 101 FEET A 2C#16 TW.UNSH.JACKETED PAIR,SLC LOOP,MID-CAP. <br /> GENERAL TROUBLE TO AES R2 RLY2 H NAC2 $2 SPARE NOTE USED-CALCULATED AT FIELD CURRENT The current fire alarm panel communicated through the security system.The new <br /> READING .O EXISTING B 2C#14,UNSH.HORN/STROBE OR NAC TRIGGER CKT.'S <br /> 9 C 2C#14,UNSH.POWER OR AUX.CONNECTION fire alarm panel will communicate to the central station monitoring via the on-board = IY <br /> DACT communicator and a new AES Transceiver Radio Communicator. W <br /> SPARE NOT USED IRS #1A. <br /> 53 SPARE NOTE USED-CALCULATED AT FIELD CURRENT ca <br /> D 2C#16,UNSH.MODULE INITIATION ZONENo-READING_0EXISTING E 2C#16 SHIELDED.TW PR.,SYSTEM BUS W ZZPARCEL#00410200002200 `F 2#14,AQUASEAL-FOR USE IN U.G.CONDUIT&WET LOCATIONS u)rnUU <br /> R4S4 SPARE NOTE USED-CALCULATED AT FIELD CURRENT G 2 16,SHIELDED AQUASEAL-U.G.CONDUIT&WET LOCATIONS H�DO SPARE NOT USED #READING-OEXISTING <br /> H 1#16,THHN-GROUND CONNECTION Z p Z Z <br /> 120VAc #14/2 #1a/z on U 00 <br /> _1._cxrl WIRING TO MEET NEC 760 STANDARDS <br /> PAGE INDEX APPROVED BY: <br /> USE UNSHIELDED WIRE UNLESS OTHERWISE NOTED. KID <br /> ALL SHIELDS MUST BE TIED THROUGH,ISOLATED,AND TERMINATED,IF USED. <br /> 10 Timothy C.Eastman-253&8ga�2M_ DRAWN BY: <br /> TE <br /> NICET C�rlif{FajfonJV6,�, FA-01 DEVICE LEGEND-DEVICE MATRIX-RISER DIAGRAM-MAP OF LOCATION-NFPA PRINT NOTES <br /> O RISER DIAGRAM 6fre9tl8r S�yBBIL��{{S Carc I0 °A� <br /> LIB FA-02 FIRE ALARM LAYOUT PLAN 11/26/24 <br /> 1 rtl ca4on Expires:March 01,2025 JOB# <br /> NOT TO SCALE 35555280 <br /> Dwc.No.�FA-Ol <br />
The URL can be used to link to this page
Your browser does not support the video tag.