ALARMFIRE . <br /> 5104 Fire Control Communicator M1 <br /> SILENT KNIGHT <br /> MODEL 5104 <br /> 120VAC 60 Hz Silent Knight <br /> 4 Channel Model 5230 <br /> Class A Input Communicator (optional) <br /> (supervised) <br /> Remote Annunciator <br /> (3 max per system) <br /> O <br /> Class B Inputs Wheelock <br /> (supervised) 46T-G10-12-R-Bell <br /> Heat detectors,manual (optional) <br /> pull stations and Tel. Line#1 <br /> TO RJ31X <br /> contact type Model6712 <br /> smoke detectors 12VDC 7 AH <br /> Tel. Line#2 <br /> MODEL 5104 BLOCK DIAGRAM <br /> Stand-alone Automatic Fire Detection Application <br /> (For Communication Only) <br /> ARCHITECT/ENGINEER The control/communicator shall have The digital communicator shall provide <br /> SPECIFICATIONS the capability to supervise two a secondary power supply utilizing <br /> The contractor shall provide an telephone lines, seize the phone line rechargeable batteries.The secondary <br /> approved digital communicator to trans- and send the alarm signal on one or supply shall be capable of supplying <br /> mit the fire alarm and supervisory and both lines without the addition of any power, under maximum normal load, <br /> trouble signals to a central station.The more equipment. It shall sound a local for 24 hours for central station or <br /> digital communicator shall be UL or FM trouble signal if the telephone service is proprietary applications or 60 hours for <br /> listed for fire reporting to a central sta- interrupted for longer than 45 seconds remote supervising station system <br /> tion and shall conform to the require- and it shall transmit a signal indicating application in accordance with NFPA 72. <br /> ments of NFPA 72. the loss of phone line service to the <br /> central station over the remaining The communicator shall be able to <br /> The digital communicator shall provide phone line.A signal shall also be trans- transmit all signals in the Standard SIA <br /> power and necessary components for matted to indicate the restoral of phone format(Security Industry Association). <br /> four supervised detection circuits.One service.The control/communicator shall <br /> shall be Style D and three shall be be able to report the loss of either The alarm signals transmitted to the <br /> Style A.The detection circuits shall phone line without regard to which central station shall indicate which of <br /> accommodate sprinkler flow switches, phone line failed first. If both lines fail, the four zones is in alarm and which <br /> gate valve supervisory switches, a local signal shall sound. zones are in trouble. Restoral from <br /> thermal detectors and contact-type alarm or trouble shall be capable of <br /> smoke detectors intermixed as desired The control/communicator shall have communicating to Silent Knight, <br /> and permitted by NFPA 72. the ability to send a test signal to the Radionics or Ademco central <br /> central station every 24 hours.The test station receivers. <br /> signal shall be able to be transmitted at <br /> a specific time of day or night by <br /> setting a program within the panel. <br /> 3 SILENT <br /> KNIGHT <br /> 7550 Meridian Circle,Maple Grove, MN 55369-4927 <br /> 1-800-446-6444 or in Minnesota (612) 493-6435 MADE IN AM E R I CA <br /> FAX: 1-800-311-1715 FORM#150349,Rev.3/96 <br />