Laserfiche WebLink
TODES1iSTtJDENT VERSION <br /> j <br /> 5 j/Lhft? 7osT.r 2' F �i� <br /> `/ d C �O � �/�� ��� KEYNOTES <br /> 041 J 7��' ✓ J 1 90 CFM FAN <br /> f�kovibi.- c fS ./1N� — 4- 2 90 CFM WHOLE HOUSE FAN <br /> 3 j1 Ci1 3 RANGE WITH 300 CFM HOOD <br /> WALL LEGEND <br /> Inn = / HO w4e�J— i Yrl//nrn o <br /> (�' �j (r�- DEMO <br /> O i« .(�3 � t_ . ` /7PC-X) EXISTING TO REMAIN <br /> s ,, / s�,_ 5,�,a4LlIj ( /7je )z) ` `� €�L NEW MATERIAL <br /> v / / NOTES <br /> - FIELD VERIFY EXISTING CONDITIONS. <br /> - ALL DIMENSIONS SHOWN+/-TO ALIGN WITH <br /> EXISTING CONSTRUCTION AND ARE TO BE FIELD <br /> VERIFIED. <br /> - FIELD VERIFY ALL EXISTING STRUCTURAL <br /> r-1 r--I r-1 0 0 000NDITIONS INCLUDING ALL BEAM,RAFTER AND <br /> _ I _ F . _ JOIST SIZES AND SPACINGS. <br /> L-_J - J — _J k - ALL STRUCTURAL MEMBERS SHOWN ARE <br /> EXISTING UNLESS OTHERWISE SPECIFIED. <br /> S'-10" 15 1' <br /> z I I I y I GENERAL NOTES 7° <br /> O _ -1 r_ o <br /> CC I ® I I I I ® I BEDROOM I I® LIVING ROOM INSTALL CARBON MONOXIDE DETECTORS PER c <br /> - W L—J L J L-J <br /> 0 3 n <br /> 2015 IRC WA STATE AMENDMENTS SECTION R315; m <br /> 1- tyI I SCo SEE FLOOR PLAN FOR LOCATIONS 17, <br /> w I I I - INSTALL 110V SMOKE DETECTORS, 00 <br /> o N� INTERCONNECT WI BATTERY BACKUP,PER 2015 n <br /> ~ r-1 r 1 r-, I��� BP 4'-a' IRC WA STATE AMENDMENTS SECTIONR314;SEE Z <br /> I -J I I I -J _ _ L.- i \ _ _ A- PLANS FOR LOCATIONS. c <br /> fn L—J L J L—J O°scD � INSTALL WHOLE HOUSE VENTILATION FAN PER -t <br /> L.L. ` M / `D 2015 IRC WA STATE AMENDMENTS SECTION m <br /> rr I M1507.3:SYSTEM SHALL PROVIDE MIN.CFM PER <br /> NOTE. RE TABLE M1507.3.3(1). En <br /> AHOWNARE RALEXISTING <br /> COING UNLESS <br /> - - 0 - ALL EXHAUST FANS TO BE LOCATED AND SIZED -i <br /> Z r—1 r-1 r—, SHOWN ARE EXISTING UNLESS <br /> I ® I I ® I I ® I NOTED OTHERWISE AND ARE TO ry ti, KITCHEN <br /> PER 2015 IRC WA STATE AMENDMENTS TABLE m <br /> m L—J L—J L—J BE FIELD VERIFIED. O BATH <br /> M1507.4. Z <br /> O I I EXISTING CRAWL SPACE / I 8'-10" Y 7-10. 10'.7" --i <br /> `L co <br /> O DOOR SCHEDULE <br /> m <br /> O _:_._.__ SW to <br /> O r-i, r r 1 •�, - 1 3'-0"X6'-8"MARVIN WOOD EXTERIOR DOOR -(5m �1 <br /> a �— I T 0 s'-T' - 0 2 3'-0"X6'-8"MARVIN WOOD EXTERIOR DOOR <br /> I � <br /> 3 © OSCD a (E)40 xe9 i I <br /> 4 __ LAUNDRY _ § 4 2'-0X6'-8 FIVE PANEL SOLID CORE INTERIOR DOOR <br /> NEW 18'X18"X18- a' , <br /> wi 4 CONC. e II 5 (1)2'-0X6'-8 HOLLOW CORE BARN DOOR PANEL <br /> I EACH WAY <br /> NEW 6"P.T.POSTS 0 DESK <br /> - T‘ ` WINDOW SCHEDULE <br /> L J L J <br /> ss^ r-3. I 0 1 (2)1-10X4'-7 MULLED MARVIN ELEVATE <br /> 3'-10 59' / 3•L9 DH WOOD WINDOWS <br /> / / / / / <br /> 5s' 10-0 r - 2 (2)1'-10X4'-7 MULLED MARVIN ELEVATE <br /> / / / / DH WOOD WINDOWS <br /> 3 (2)1'-10X4'-7 MULLED MARVIN ELEVATE <br /> 0 FOUNDATION O FLOORPLAN DH WOOD WINDOWS <br /> 1 Scale,0/4",r-0" 4 (1)2'-3x3'-4 MARVIN ELEVATE WOOD <br /> CASEMENT WINDOW <br /> 5 (2)1'-10X4'-7 MULLED MARVIN ELEVATE McCulley <br /> WOOD CASEMENT WINDOWS 1416 12th St <br /> 6 (1)2'-0X3'-0 MARVIN ELEVATE WOOD Everett Wa 98201 <br /> CASEMENT WINDOW <br /> ''VMcCulley 10 <br /> 6/12/20 Plan <br /> SW. <br /> %41= 11-011 <br /> NOIS213A INJUf IS HS3©O1f1V NV AR 03'11 (1J.i <br />