1 1 2 1 3 1 4 1 5 1 6 I 7 1 8 1 9 1 10 1 11 <br /> H <br /> MECHANICAL PENTHOUSE <br /> D,�::-WORK TO BE DONE IN THESE PANELS ■r PROVIDENCE <br /> PANEL :PANEL T-ECC6PANEL Health&Services <br /> ABNBGA i'E ECC66100AA <br /> �I - LO T MCB <br /> ELEV. 4 - STH FLR/ROOF LOBBY IL PROVIDENCE <br /> SENIOR <br /> SERVICES <br /> CESD <br /> 1-1/4"C,4#2,1#6G ROOF <br /> 2001 LIND AVE SW <br /> PANEL 3-1 2"C,4-500KCMIL,1 2G 1"C-4#6,1#10G SUITE 180 <br /> ECC5 I / # I 3/4"C-3#10,1#10C RENTON,WA 98057 <br /> PANE <br /> 150A <br /> MLO PANEL <br /> ROOF L J A8XAL A8NA Pad tA <br /> ggCBi A8CB2 <br /> I SECT 00A A�.A SECT1 SECT2 I <br /> G 2-1/2"C,4#3/0 4" C-4#500KCMIL, 1#1/OG MILO2,1#6G STH FLOOR PROVIDENCE <br /> PANEL PANEL PANEL L 2-1/2 C,4#4/0,1#2G 11- <br /> "C,4-50OKCMIL,#2G EVE R ETT <br /> PANEL PANEL 3L 3L 94NA <br /> 3K 3W SECT1 SECT2 1GOA 1-1/2"C,4#1/0,1#6G 2-1/2"C,4#4/0,1#4G H O S P I C E <br /> MLO 1-1/2"SPARE RACEWAY FOR FUTURE <br /> 2-1/2"C,4#3/0 TELEPHONE/DATA. PANEL PANEL PANEL PANEL <br /> 4TH FLOOR A7XA A7NA 6A 6A PANEL <br /> SECT, MLO SECT1 SECTS 6N2"C,4#2 4" C-4#500KCMIL, 1#1/OGA-Wing 8th Floor <br /> C4-5#6G2-1/2"C,4#3/0 2-1/2"C4#4/0,1#2G C,4-500KCMIL,1#2G 2"C,4-#1/0,1#6G 7TH FLOOR 1321 Colby Ave <br /> Everett,WA 98201 <br /> PANEL PANEL PANEL B3NAL B3XAL 1#1/OG 2-1/2"C,3#4/0, <br /> 2K 2W 2L <br /> 100A 100A 1#1/OG <br /> MILO MILO <br /> 3RD FLOOR 2-1/2"C,4#3/0 �i PANEL <br /> PANEL PANEL PANEL PANEL 1#1/OG iA . <br /> A6NA 5A 5A 5N 5N PANE <br /> 2"C,4#2 ia,x wi MLO SECT1 SECT2 SECT1 SECT2 5B <br /> F 2-1/2"C4#3/0 1"C-4#6, 1#6G 1"C-4#6, 1#6G --J <br /> 2-1/2"C,3#4/0, 1110112TH AVE.NE I SUITE 500 <br /> 1#1/OG 6TH FLOOR <br /> PANEL PANEL PANEL PANEL PANEL PANEL BELLEVUE,WA 98004 <br /> iK iL B2NC B2NB B2NA B2XA 2-1/2"C,3#4/0, 2-1/2"C,3#4/0' t425.463.2000 f425.463.2002 <br /> 50A 50A 100A 100A <br /> 1#1/OG 1#1/OG <br /> MLO MLO MLO MLO <br /> 2ND FLOOR 2-1/2"C,4#3/0 <br /> 2-1/2"C,3#4/0, MUlvannyG2.wm I <br /> 2-1/2"C,4#3/0 /rA5XA <br /> NEL PANEL PANEL PANEL PANEL PANEL PANEL 1#1/OG <br /> A5NA A5CA A5CA ASCC ASCC A5CB <br /> 25A 400A SECT1 SECTS SECT1 SECTS1-1/2"C-4#2, 1#6c LO MLQ CONSTRUCTION SET <br /> 1-1/4"C-4#2, 1#4G EXISTING CORE DRILL IN SLAB FOR INSTALLATION 4" C-41500KCMI, 1#1/OG STH FLOOR .t .t �t <br /> 2"C 4#2 OF 2-1/2"0 FEEDER FOR 5X RISER. 05. 1 1.20 1J <br /> 1-1/4"C-4#2, 1#2G � 2-1/2"C-4#4/0, 1#4G 1#1/OG _ <br /> 2#/2"C,3#4/0, <br /> ELECT. CLOSET B102 ELECT. CLOSET®LAB ELECT. CLOSET 109 LAB #6 PANEL PANEL 2-1/2"C,3#4/0, <br /> 3"C,4#4/0 3X A4NA <br /> 225A 40OA PANEL PANEL PANEL PANEL 1#1/OG S P A R L [ N G <br /> MLO MLO 3A 3A <br /> SECT1 SECT2 3N 3B <br /> E PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL CI StanteC Compcny <br /> PANEL PANEL PANEL GN GN PANEL RAD XR1 XR1 B1NA B1XA 31CA ECC4 BiNC Bi CB BiCC B1NB B1XB CBS <br /> ELEV#4 GK GW GL SECT1 SECTS E 100A SECT1 SECTS 225A 225A 400A 400A 100A 100A 100A ,OOA 100A 1GOA 4" C-4#500KCM1, 1#1/OG 4TH FLOOR <br /> MLO MILO MILO MCB MLO MLO MLO MLO MLO MLO MCB <br /> (o (o (a 2-1 2"C,340, 2-1 2"C,340, / # # <br /> ¢ a ¢ / #/ / # / 1-1 2"C-4 2, 1 6G Stantec <br /> n o 0 o N o 0 0 0 3"C,4#4/0 Ii ii 1#1/OG 1#1/OG <br /> 1ST FLOOR 3-1/2"C,3-500KCMIL,1#3/0 L PANEL PANELT PANEL <br /> 2-1/2 C-4#4/0 1#4G 1-1/2"C-4#2, 1#6G 225A 400A 100A <br /> (2)3-1/2"C,3-500KCMILJ#3/0 <br /> MLO MLO PANEL PANEL PANEL PANEL MLO <br /> DISTRIBUTION PANELBOARD #3 2A 2A 2N 2N PANEL <br /> 208Y/12OV, 3PH. 4W 3-1/2"C-4#500KCMIL, 1#1/OG SECTi SECTS SECTi SECTS 2B <br /> PB 4" C-4#500KCMIL, 1#1/OG <br /> 3RD FLOOR <br /> 3 1/2"C-4#600 kCMIL, 1#1/0G B WING <br /> TO PANEL HCC <br /> TO EUS-EH1 2-1/2"C-4#4/0 1#4G 1-1/4"C-4#2, 1#4G �4"C-4#500KCMIL, 1#1/OG <br /> RB-79,81,83 2_1/2"C-4#4/0 1#4G r2-1/2"C,3#4/0, 2-1/2"C,3#4/0, <br /> 1"C-4#8, 1#1 OG 1 1#1/OG 1#1/OG <br /> 17 <br /> 14 2-1/2"C,3#4/0,1#1/OGND <br /> D 3-1/2"C-4#300 KCMIL&1#4 G 3-1/2"CA-500KCMIL,1#2G <br /> 3/4"C AND CONTROL <br /> # <br /> 1 GND. WIRES TO GENERATOR <br /> FOR START SIGNAL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL <br /> TRANSFORMER T-ECCB, 225 KVA NON - K13 CiNA C1CA Ci C6 RC RR BIND EP KP2 KP2 ENEL MCC PANEL PANEL PANEL iC iC PANEL PANEL <br /> RATED, 480V-208Y/120V,30,4W XFMR T-ES1 (5)4"C-(5)500KCMIL ATS-LS 225A 100A 100A <br /> 750KVA, &(1)350KCMIL G 400A, 4P MCB MCB MCB SECTi SECTS #1 1A iN iB SECTi SECTS RX XR2 <br /> 480-208Y/120V,30,4W K-4 O (LIFE SAFETY) <br /> RATED 1-1/2"C,4#2,1#8G <br /> CT SUITE ROOM 102 <br /> • � 2ND FLOOR 5,659 <br /> CB 00 2"C,4#2 1"C,3#4,1#8G <br /> 35KAIC ( 2-1/2"C, <br /> DIST. DIST. All .1 LIFE SAFETY DIST. PANEL LS-1 4 3 0 MCC-3A MCC-3 MCC-2 PANEL PANEL PANEL <br /> 160OA/3P O ( )3"C,3-350KCMIL,1 3 0 #/ UPS UNIT <br /> PANEL PANEL T a #/ (2)3"C,3-250KCMIL,1#4 <br /> M M M M M E N 400A, 208Y/120V,30,4W GP CP1 Al CH1 <br /> ECC3 ECCB =#3/0 \ \ \ \ oo \ 3-1 2"C,4-500KCMILI 2 f D. <br /> ZT.ATS-EC2 400V 208V a a ¢ a a a a / # Fe o O <br /> EMERGENCY SWITCHBOARD ES-1 0 0 I�n u� ( I o I a a 0 U 1#8 WA 9 <br /> (o(o `N(N \��`o `(o (2)3"C,3-500KCMIL 7A,Jr.480V 700A ( ) of N <br /> MCB MCB 1600A, 208Y/120V,30,4W 1a is 1N 1N a 2 C <br /> I N <br /> N <br /> (2) 3"C-4#400 KCMIL,1#1/OG 60.63A _ _ _ , <br /> 3"C,3#4/0,1#4m M a <br /> 3 1/2"C-4#600 KCMIL,1#1/OG a a a a COMPUTER PANEL <br /> BUILDING "A' N � � � 3-1/2"C,4#500KCMIL,1#2G iTE <br /> 3 1/2"C-4#500 KCMIL,1#1/OG = MAINTENANCE SHOP - - - EQUIPMENT 38180 <br /> L #3/OGND J NORMAL DISTRIBUTION PANEL (NP-1) FREIGHT PNEUMATICS RISTE4 <br /> ELEV 2 ONAL ' <br /> 1000A, 208Y/120V, 30, 4W ELEV. # TUBE SYSTEM 1"C-4#6,1#8G Sj <br /> (4)3-1/2"C,4-500KCMIL,1#4/0 a aELEV#3 <br /> C I�(QI Q(a I Q I Q O PANEL PANE PANEL PANEL PANEL PANEL PANEL PANEL (�.>•r'�� <br /> REMOTE 1,n1,nl,n o 1 0 1 o PANEL PANEL PANEL PANEL PANEL PANEL <br /> METERS N N N o o LP LP KP-1 ECT ECT KP-1 KP-1 PB1A <br /> a < N SM 1E GB GA GY GX <br /> SECTS SECT1 2-1/2"C SECTS SECT4 SECT3 SECTS SECT1 <br /> M M 4#4/0 CAROLINE JONES,ARCHITECT <br /> 1-1 2"C,4#4 2"C 4#2 <br /> "(2)1 <br /> 3"C,3-500KCMIL 3 C PANEL <br /> DEELI FRY (7)4T OF "C-4#500KCMIL 4#400kcmi MCC-4X 3-350KCMISNOHOMISH CO. SNO. CO. PUD 1#2/OG 4X <br /> PUD OVERHEAD TRANSFORMER #350KCMIL <br /> _ DISRTIBUTION IN VAULT. 2"C,3#3/0 <br /> LINE. 12.47KV-208Y/ (5)4"C-4#600KCMIL (2)3-1/2"C,3-500KCMIL,1#3/0 2"C,4#2 <br /> 120V,3PH,4W 3-1/2"C,3-500KCM IL,1#3/0 <br /> 3"C,3#350KCMI L,1#12 <br /> o A O a d a 2w 24 a FIRE <br /> in v, ut aUMP <br /> �, sareN.�wnn <br /> < M 3 O O O 2 \ \ \ 5 O2 O4 O3 1 OO O 18 O 14 77 13 8 O O O ¢ 15 O9 19 10 20 17 16 22 O6 11 12 21 25 CONT. �o,q.,ym steam" <br /> f:J \ / ¢ M w 1 e,IXi�niuwn wmi 9Bom Murvennvc3aMireclure. <br /> ( V D_ d T \ M M M 1¢ 1N la M M M M M M M M M M IM IM dM M M M M M M M M M M M dM dM <br /> O\ dM dM d\ \ I a a Q \ I M I\ I\ I\ O \ O (\I\ \ \ I\ \ \I\ I\ I\ (\ /\ Ibbb\ Ibbb\ (\ (\ \ \ \ \ \ \ \ I\ \ I\ \ \ I\ \I\ I\ \ <br /> R a ¢ (o '�o (o (o (o (o (¢ (o (o (o a N (0 (0 (0 (o (o (o(o (o (o (0 1 0 (o (o (v (o (0 1 0 (o (0 0 (0 (u�i (0 (uaj 1 u¢j (0 1 0 (0 (0 1 0 (< 1 0 1 0 (0 30HP PDATE n DESCRIPTION <br /> O O O O O O O O O O v v O O O O O O O O O O O O O O O N N O O O N O O O <br /> w N o o a o M �- co a a ro w a M a N ro N N a a N N M FIRE PUMP <br /> B W . M M M M <br /> m TO EUS-EHi 2000A BUS O <br /> \ \ BUS#1 a .f a ,.f¢¢ a <br /> ¢ 750KVA DRY TYPE (o (o (2500A) (0 'i1 o i1 0o BUS #3(1600A) BUS #4 (1200A) F o <br /> 0 0 o N eus#2 (zs oq) Bus#5 (1600A) <br /> TRANSFORMER. N NORMAL CRITICALO NON-ESSENTIAL E b b �O 00 <br /> hh NORMAL CRITICAL <br /> 480V-208Y/120V f V f f A <br /> m 3PHAW. <br /> O O O <br /> LL GENERAL EMERGENCY DISTRIBUTION SWITCHBOARD (5)3- /2"C- <br /> 208Y/12OV-3PH.4W #SOOKCMIL <br /> MAIN SWITCHBOARD #1 <br /> A WING 208Y/12OV-3PH.4W <br /> ATS-NE O E N O E N O E N ATS-C <br /> 1200A, 4P 1600A, 4P <br /> na (NON-ESSENTIAL) (CRITICAL) <br /> 1ST FLOOR 14-0197-01 <br /> n <br /> PM:MDJ <br /> ATS-CC� <br /> o� 1600A,E4P (4) 3-1/2" C - 3#500 KCMIL, 1#250KCMIL <br /> FLAG NOTES: <br /> we (CRITICAL EQUIPMENT) REFER TO SHEET EO.02 FOR PANEL SCHEDULES. EXISTING HOSPITAL <br /> iN A (3) 3" C - 4#500 KCMIL NEW PANEL NAME ON EXISTING PANEL REFER TO SCHEDULES ON SHEET E0.02 POWER RISER DIAGRAM <br /> POWER RISER DIAGRAM-WINGS A&B(208V) WINGS A&B (208V) <br /> m� QNE <br /> E8.21 <br /> 0 <br /> w <br /> k� ` City of Everett Permit Services <br /> o� <br /> a� <br /> i EVERETT Reviewed for Permit 5 <br />