Laserfiche WebLink
1 1 2 1 3 1 4 15 I 6 1 7 I 8 I 9 110 111 <br /> H SYMBOLS AND ABBREVIATIONS <br /> ■r PROVIDENCE <br /> Health&Services <br /> NURSE CALL CIRCUITS <br /> ITS <br /> OR LIGHTING PANELBOARDS CIRCUITS WORK DEFINITION <br /> EMERGENCY <br /> PROVIDENCE SENIOR AND <br /> H SINGLE BED STATION N/A —J LOWER-CASE LETTER NEAR FIXTURE DENOTES SWITCH LEG,TYP � 208V SYSTEM PANELBOARD �«N— RACEWAY CONCEALED IN CEILING OR WALL.HASH MARKS ® FLAG NOTE COMMUNITY SERVICES <br /> U 2001 LIVID AVE SW <br /> INDICATE NUMBER OF WIRES.#12 AWG WIRE UNLESS OTHERWISE SUITE 180 <br /> I-a TOILET EMERGENCY STATION �o 00 RECESSED FLUORESCENT FIXTURE,DRAWN TO SCALE 9!6 480V SYSTEM PANELBOARD NOTED.EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. ® REVISION IDENTIFICATION RENTON,WA 98057 <br /> $ DOME LIGHT(CEILING MOUNTED) WALL MOUNTED FLUORESCENT FIXTURE,LENGTH TO SCALE HOT(SHORT HASH MARK) ®EQUIPMENT IDENTIFICATION <br /> l IIII 4 (NUMBER OF MOUNTING POINTS WILL VARY WITH FIXTURE <br /> I-(IJ DOME UGHT(WALL MOUNTED) LENGTH) ELECTRICAL RISER + NEUTRAL(LONG HASH MARK) # EQUIPMENT IDENTIFICATION <br /> G TTA ANNUNCIATOR(DESK MOUNTED) ® 0 ElO RECESSED DOWNLIGHT FIXTURE <br /> ❑ ( )FEEDER SIZE IDENTIFICATION GROUND WIRE(JOGGED HASH MARK) Sh.1N DETAIL REFERENCE PROVIDENCE <br /> ]$[ PENDANT MOUNTED FIXTURE AVAILABLE FAULT CURRENT IDENTIFICATION EXISTING <br /> RACEWAY(IF HASH MARKS ARE SHOWN,PULL NEW Plmsn�.1 0.1� f DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE EVERETT <br /> II444 WALL MOUNTED FIXTURE ----AUTOMATIC TRANSFER SWITCH PROJECT NORTH REFERENCE RACEWAY BELOW SLAB OR UNDERGROUND HOSPICE <br /> ELECTRONIC SECURITY EXIT SIGN,FILLED SIDES ARE ILLUMINATED,DIRECTIONAL D <br /> ® N/A ARROWS AS INDICATED RACEWAY UP <br /> .a <br /> SPACE BUS SPACE y� <br /> OQ CCTV CAMERA N/A e G CEILING MOUNTED WALL WASH FIXTURE,OPEN AREA INDICATES RACEWAY DOWN a D PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE <br /> 8 0 DIRECTION OF ILLUMINATION BUS DUCT <br /> CR CARD READER RACEWAY STUB-OUT WITH BUSHING NEW WORK A-Wing 8th Floor <br /> N/A SCIL <br /> ALEEl EXISTING CEILING MOUNTED LINEAR WALL WASH FIXTURE,LENGTH TO IA BUSWAY END TAP BOX 1321 Colby Ave <br /> TELECOM CABLE TO BUS CONNECTION CIRCUIT CONTINUATION Everett,WA 98201 <br /> V V MONOPOINT FIXTURE <br /> HOME RUN TO PANEL OR LOCATION NOTED ----- FUTURE <br /> ♦ OUTLET(WALL MOUNTED) N/A \y rj TRACK LIGHTING n CIRCUIT BREAKER <br /> OJ J❑ JUNCTION BOX � REMOVE EXISTING ELECTRICAL EQUIPMENT <br /> WAP WIRELESS ACCESS POINT ,CIRCUIT BREAKER DRAWOUT <br /> N/A CONTINUOUS LINEAR SOURCE,SEE ARCHITECTURAL FOR ACTUAL <br /> FIXTURE } CIRCUIT BREAKER,DRAWOUT,MEDIUM VOLTAGE CIRCUITS GENERAL NOTES F TELECOM OUTLET TYPES N/A UNDERCOUNTER TASK LIGHT GF RECEPTACLES <br /> °'° "°"� <br /> CIRCUIT BREAKER,GFI 1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL <br /> 1 N/A Ho NIGHT LIGHT >. DUPLEX RECEPTACLE 120V AUTHORITY HAVING JURISDICTION. 1110112TH AVE.NE I SUITE 500 <br /> � <br /> ♦ INDICATES QUANTITY OF DATA JACKS.PULLSTRING ALWAYS CIRCUIT BREAKER,GFI WITH DRAWOUT g BELLEVUE,WA 1 98004 <br /> PROVIDED.WHERE NO QUANTITY IS NOTED,3 DATA JACKS AND ® FIXTURE IDENTIFICATION,SEE LIGHTING FIXTURE SCHEDULE � $ DOUBLE DUPLEX RECEPTACLE 120V 2. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED ARCHITECTURAL PLANS <br /> PULLSTRING. OR) ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ONN THE ELECTRICAL 1425.463.2000 1 f425.463.2002 <br /> 8®U-FUSE OR CURRENT LIMITER DRAWINGS. <br /> RECEPTACLE 208V OR 240V,SINGLE PHASE <br /> ♦AC MOUNTED 3'ABOVE COUNTER BACKSPLASH LIGHTING SWITCHES AND CONTROLS �� FUSE(ISOLATING) 3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING FIXTURE LOCATIONS. <br /> MUlvannyG2.wm I <br /> ♦B TIN SPLIT HIRED RECEPTACLE,120V BLANK FACEPLATE(ROUGH-IN ONLY) `�� FUSED SWITCH 4. FOR LIGHTING CONTROLS WHICH INCLUDE OCCUPANT SENSING AUTOMATIC CONTROLS,AUTOMATIC <br /> W $u CONTROLLED(TV)R NEAR SWITCH DENOTES CIRCUIT �� RECEPTACLE TYPES SHUT-OFF CONTROLS,OCCUPANCY SENSORS,OR AUTOMATIC TIME SWITCHES THE LIGHTING CONTROLS <br /> ♦ TELEPHONE HANDSET OUTLET(WALL MOUNTED) SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT,AND SYSTEMS ARE <br /> 0 i GROUND CALIBRATED,ADJUSTED,AND OPERATE IN ACCORDANCE WITH PROJECT PLANS AND SPECIFICATIONS. CONSTRUCTION SET <br /> OCCUPANCY SENSOR SWITCH G SEQUENCE OF OPERATION SHALL ALSO BE FUNCTIONALLY TESTED TO ENSURE IT IS OPERATING IN <br /> FIRE ALARM b DIMMER SWITCH SPLICE Qb GROUND FAULT CIRCUIT INTERRUPTER ACCORDANCE WITH PROJECT PLANS AND SPECIFICATIONS.A COMPLETE REPORT OF TEST PROCEDURES <br /> QbT TAMPER RESISTANT AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 05.11.201 5 <br /> �• SWITCH,2-POLE <br /> Q SMOKE DETECTOR CONTROLS H WIP GROUND <br /> FAULT CIRCUIT INTERRUPTER WITH WEATHER PROOF 5 COMPLETE ELECTRICAL INCLUDESWORK PERFORMED SYSTEM ASAINDICATED ON THESE LS,AND EQUIPMENT REQUIRED <br /> DRAWINGS ANDASISPECIFIED.STALL A <br /> COVER <br /> STROBE LIGHT(WALL MOUNTED) A SWITCH,3-POLE U <br /> DISCONNECT SWITCH ` Qb COMBINATION DUPLEX RECEPTACLE WITH USB CONNEC110N 6. ALL ELECTRICAL CONDUIT AND JUNCTION BOXES SHALL BE CONCEALED.CONTRACTOR SHALL <br /> OD SMOKE/FIRE DAMPER CONNECTION oa COORDINATE WITH OTHER TRADES AND USE CHASES AND CEILING SPACES PROVIDED. S PA K L I N G <br /> E D SMOKE DOOR RELEASE MECHANISM,COMBINATION DOOR I] 0 PUSH BUTTON CONTROL STATION THERMAL ELEMENT 7. DRAWINGS ARE INTENDED TO SHOW GENERAL ARRANGEMENT,DESIGN,AND EXTENT OF WORK AND a Stantec Company <br /> ❑ CLOSER/HOLDER TYPE ARE MORE OR LESS DIAGRAMMATIC.DRAWINGS ARE NOT INTENDED TO SHOW EXACT LOCATIONS <br /> T AUTO DOOR PUSHPLATE �,1,,� �.li TRANSFORMER EXCEPT WHERE DIMENSIONS ARE SHOWN.ELECTRICAL WORK IS SHOWN USING STANDARD INDUSTRY <br /> F❑ MANUAL STATION(WALL MOUNTED) M ryyy,% M SYMBOLS.BEFORE ORDERING MATERIALS OR DOING WORK,THE CONTRACTOR SHALL VERIFY ALL Stantec <br /> MOTOR RATED TOGGLE SWITCH TRANSFORMER,CURRENT MEASUREMENTS PRIOR TO PURCHASE AND INSTALLATION.ANY SUBSTANTIAL DIFFERENCES BETWEEN <br /> F SPEAKER AND STROBE LIGHT(WALL MOUNTED) DRAWINGS AND CONDITIONS IN THE FIELD SHALL BE SUBMITTED TO THE CONSTRUCTION MANAGER FOR <br /> TRANSFORMER,MAGNETIC CORE SHOWN CONSIDERATION BEFORE PROCEEDING WITH WORK. <br /> FATC TERMINAL CABINET EQUIPMENT , 8. PROVIDE FUSED DISCONNECT SWITCHES FOR ALL MOTORS,UNLESS NOTED OTHERWISE.PROVIDE MOTOR <br /> G ENGINE-GENERATOR STARTERS FOR ALL MOTORS WHICH ARE NOT PART OF A PACKAGED UNIT BEING FURNISHED BY THE <br /> SMOKE MOUNTED) EQUIPMENT RELEASE MECHANISM,MAGNETIC TYPE(WALL o EQUIPMENT CABINET OUTLET MOUNTING HEIGHTS STARTER,CONTRACTOREQUIPMENT SUPPLIER.WHERE SHALLCPROVIDETAR SUPPLIES BOTH FUSED COMBNAT10NSED STTARITER UNIT. <br /> SWITCH AND MOTOR <br /> ® ®E PM EQUIPMENT CONNECTION,E=EMERGENCY POWER POWER METER 9. CONTRACTOR SHALL VERIFY ALL EQUIPMENT SIZES AND POWER REQUIREMENTS FOR EQUIPMENT <br /> SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL SUPPLIED BY OTHERS. <br /> AUDIO VISUAL b MOTOR CONNECTION,SINGLE PHASE DRAWINGS.IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED,THEN LOCATE OUTLETS AS <br /> NOTED BELOW.OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF 10 CONTRACTOR AT HIS/HER OPTION,MAY COMBINE CONDUIT RUNS FOR FEEDERS PROVIDED THAT THE <br /> MOTOR CONNECTION,3 PHASE THE OUTLET UNLESS OTHERWISE NOTED. AMPERE RATING OF THE CONDUCTORS IS DE-RATED PER NEC ARTICLE 310.. <br /> RE3 AUDIO VISUAL PANEL(WALL,FLUSH MOUNTED) <br /> RECEPTACLES 18 INCHES(460 mm)VERTICALLY MOUNTED 11. MULTI-WIRE BRANCH CIRCUITS NOT PERMITTED.PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH <br /> OS SPEAKER(CEILING,FLUSH MOUNTED) CIRCUIT. <br /> SWITCHES 43 INCHES(1095 mm)VERTICALLY MOUNTED <br /> SPEAKER(CEILING,SURFACE MOUNTED) 72 INCHES(1830 mm)TO TOP OF PANELBOARD IF BOX<68 <br /> D PANELBOARDS INCHES(1730 mm)HIGH,OTHERWISE PER NEC 404.8 <br /> TV CATV OUTLET(WALL,FLUSH MOUNTED)REFER TO DETAIL 2,SHEET E9.00 CARD READER 43 INCHES(1095 mm) <br /> VC VOLUME CONTROLLER,(WALL,FLUSH MOUNTED) <br /> TELECOM OUTLET,DESK HANDSET 18 INCHES(460 mm)VERTICALLY MOUNTED ABBREVIATIONS <br /> TELECOM OUTLET 43 INCHES(1095 mm)VERTICALLY MOUNTED ABV ABOVE MW MICROWAVE <br /> VOLUME CONTROLLER 43 INCHES(1220 mm) AFF ABOVE FINISHED FLOOR N NEUTRAL <br /> A,AMP AMPERE PNL PANEL,PANELBOARD <br /> FIRE ALARM PULL STATION 43 INCHES(1095 mm) AWG AMERICAN WIRE GAUGE PR PAIR <br /> CATV COMMUNITY ACCESS TELEVISION PTS PNEUMATIC TUBE STATION �$''oeDasy9� <br /> TOP EDGE NOT LESS THAN 90 INCHES(2290 mm)AFF AND NOT CB CIRCUIT BREAKER R RACEWAY <br /> FIRE ALARM AUDIBLE NOTIFICATION LESS THAN 6 INCHES(155 mm)BELOW CEILING.6 INCHES(155 <br /> DEVICES mm)BELOW CEILING SHALL TAKE PRECEDENCE WHERE COILING CCTV CLOSED CIRCUIT TELEVISION RECEPT RECEPTACLE - - <br /> HEIGHT DOES NOT ALLOW BOTH DIMENSIONS CKT CIRCUIT REF REFRIGERATOR <br /> COMM COMMUNICATIONS SPECS SPECIFICATIONS o k Sat ao <br /> FIRE ALARM VISUAL AND BOTTOM EDGE NOT LESS THAN 80 INCHES(2035 mm)AFF AND C CONDUIT SW SWITCH S ONALCOMBINATION � ' <br /> C NOTIFICATION DEVICES/VISUAL TOP EDGE NOT GREATER THAN 96 INCHES(2438 mm)AFF. CU COPPER SWBD SWITCHBOARD r <br /> D DATA TELECOM TELECOMMUNICATIONS <br /> DW DISHWASHER TV TELEVISION <br /> CAROLINE JONES,ARCHITECT <br /> FA FIRE ALARM TYP TYPICAL <br /> DRAWING LIST G,GND GROUND UON UNLESS OTHERWISE NOTED <br /> EO.00 SYMBOLS,ABBREVIATIONS,DRAWING LIST GFI,GFCI GROUND FAULT CIRCUIT V VOLT OR VOICE <br /> EO.01 ELECTRICAL SPECIFICATIONS,FIXTURE SCHEDULE INTERRUPTER W WIRE,WATT,OR WALLPHONE <br /> EO.02 ELECTRICAL PANEL SCHEDULES <br /> E1.01 LEVEL 8 A-WING DEMOLITION PLAN HP HORSEPOWER WAR WIRELESS ACCESS POINT <br /> E2.01 LEVEL 8 A-WING LIGHTING PLAN WEST IH INSTA-HOT WATER DISPENSER WP WEATHERPROOF <br /> E2.02 LEVEL 8 A-WING LIGHTING PLAN EAST <br /> E3.01 LEVEL 8 A-WING POWER PLAN WEST J-BOX JUNCTION BOX XFMR TRANSFORMER <br /> E3.02 LEVEL 8 A-WING POWER PLAN EAST MGAP MEDICAL GAS ALARM PANEL 0 PHASE <br /> E4.01 LEVEL 8 A-WING SYSTEMS PLAN WEST <br /> E4.02 LEVEL 8 A-WING SYSTEMS PLAN EAST MTD MOUNTED <br /> E8.01 PRIMARY POWER RISER DIAGRAM EMERGENCY SYSTEM <br /> E8.21 EXISTING HOSPITAL POWER RISER DIAGRAM WINGS A&B(208V) <br /> c0 E8.22 EXISTING HOSPITAL POWER RISER DIAGRAM WINGS B&C <br /> 0 <br /> E9.00 ELECTRICAL DETAILS ��b. <br /> DATE DESCRIPTION <br /> w <br /> B <br /> m <br /> 0 <br /> U <br /> m <br /> IL <br /> LL <br /> a <br /> n 5'. <br /> w� 14-0197-01 <br /> �M <br /> PM:MDJ <br /> C� <br /> w� <br /> o� <br /> ws SYMBOLS, <br /> <s A ABBREVIATIONS, <br /> o� DRAWING LIST <br /> Nm <br /> I <br /> m� E0.00 <br /> 0 <br /> w <br /> k� ` City of Everett Permit Services <br /> OR <br /> a� <br /> i EVERETT Reviewed for Permit 5 <br />