Laserfiche WebLink
Permit d 7432 Rainier <br /> ��, <br /> ALEXANDER COURT APARTMENTS Site Address Unit Rainier Or <br /> Applicant: Fire Protection Inc <br /> Application Date:07/23/2024 FIREPROTECT/ON/NC. <br /> Description: Unit A4 8 Attic,Install Wireless Fire Alarm Communicator 17410 Ash Way,Ste 8 <br /> Review Date: 08/01/2024 Lynnwood,WA 98037 <br /> 425-290-9600 <br /> FPISEATTLE.COM <br /> W O E E S S COMMUMCATOR IS T A A T O Everett <br /> S te Dept.Remit <br /> —Appro ed Review <br /> Reviewed By: <br /> 08/01/2024 3:04:54:04:54 <br /> PM <br /> REPORTING ZONE FROM RADIO TYPICAL INSTALLATION DETAIL SHEET/NDEX NFPA® <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> CENTRAL STATION REPORTING ZONES FA 0.0 FIRE ALARM AES INSTALLATION ROYLCATS <br /> ACCOUNT # AES-**** AlQp0TECT7O <br /> PROJECT DETAILS Q ? <br /> ZONE # ZONE DESCRIPTION W NIn <br /> 1 GENERAL ALARM 1. THE EXISTING TWO-STORY BUILDING IS NOT SPRINKLED AND HAS AN EXISTING CONVENTIONAL FIRE ALARM Y NFPA ` <br /> CONTROL PANEL( FIRELITE MS-5012 FIRE PANEL ) LOCATED IN UNIT A4 ATTIC SPACE. b y <br /> 2 SUPERVISORY 2. A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88-ULP) IS BEING INSTALLED, SIGNALS WILL BE �j CFPS Y <br /> 3 TROUBLE C, TRANSMITTED BY ZONE TO THE ILL LISTED SUPERVISING STATION. A 12VDC 12Ah BATTERY WILL BE INSTALLED #1473 <br /> IN THE NEW AES RADIO. <br /> O O O O O O 3. THE NEW AES RADIO WILL USE THE EXISTING FACPs DIALER TO SEND CONTACT ID AND ONBOARD RELAYS TO <br /> TRANSMIT THE FOLLOWING HARDWIRED SIGNALS TO THE CENTRAL SUPERVISING STATION: ZONE 1: FIRE ALARM, <br /> n® ❑O 0 0 0 0 AND ZONE 2: TROUBLE. y e <br /> VICINITYMAP sT..uu NUN _ <br /> p T r� 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK S INCLUDED N THIS SCOPE. <br /> ® <br /> mom <br /> Il'�II 5. IF SIGNAL STRENGTH IS NOT ADEQUATE WITH THE AES A HW-TG7LA(V)FO2 TELGUARD WILL BE INSTALLED. <br /> A�vA 6. REVIEW THE APPROVED FIRE ALARM PLAN AND PERMIT CONDITIONS FOR AHJ SPECIFIC MONITORING <br /> ree�SUP ALARM INSTALLATION REQUIREMENTS. ¢F m W <br /> ® <br /> © O O PROJECT CONTACT INFO a f <br /> `T.ulalip Indian Reservation TFemm _FR =o <br /> 1 <br /> OWNER/TENANT FIRE ALARM CONTRACTOR Y¢w <br /> DIDIS IN <br /> Marysville ALFRED JUBIE CONSTRUCTION FIRE PROTECTION INC z m rc C <br /> 1821 19TH DRIVE 17410 ASH WAY, Ste 8 y o u.ur 3 <br /> r O 00000000 O MUKILTEO, WA 98275 LYNNWOOD, WA 98037 M 3 w V W <br /> zonLs$�� CONTACT ALFRED JUBIE CONTACT DAVID MOW ;w x a o <br /> � PHONE : 425.239.4027 PHONE : 425.290.9600 <br /> aT KATHY®JUBIE.COM DAVID@FPISEATTLE.COM o rc H a o <br /> meameaeea aiz ie rs0 <br /> Everett REVISION RECORD <br /> WIRINGTOBE <br /> CODE INFO DATE DESCRIPTION <br /> AUTHORITY HAVING JURISDICTION : CITY OF EVERETT <br /> 7432 Rainier Dr, LLZFIRE CODE : INTERNATIONAL FIRE CODE, 2021 EDITION <br /> Everett,WA 98203 �X <br /> �I BUILDING USE AND OCCUPANCY : (R2) - NOT SPRINKLED <br /> Puget 1 2V 2Ah STANDARDS: 2021 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT STANDARDS <br /> pound Monroe <br /> BATTERY CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> Edmonds REMOTE SUPERVISING STATION : SECURITAS INC. <br /> Q PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> 522 F.MIFIR=IvS-5012 FIRE ALARMCONTROL PANEL PARCEL NUMBERS 00394000009502 <br /> Shoreline Bothell AES-7707-88-ULP RADIOCONMJNICATOR <br /> INSTALLATION NOTES <br /> TYPICAL VARM AND INSTALLATION DETAILS 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS-BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> SITE PLAN SEQUENCE OF OPERATIONS <br /> 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). DATE: 07/08/2024 <br /> 5. THE SYSTEM WILL BE 100% PRE-TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND PROJECT NAME <br /> SYSTEM OUTPUTS PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL <br /> Required Fire Safety Control INSPECTION. <br /> Not to Scale Central Supervising Station ®m 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> Control Unit Annunciation r DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> Q w w .o TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE W <br /> >- > 9 r r° ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT � <br /> FACPin of0 or ° omm (NFPA72, SECTION 10.5.5.2). <br /> A4 ATTIC ce 11 ;v r y+R i m W M <br /> CD <br /> Sae CD <br /> Z >i r' a »'1, or co' d 00 <br /> OUTDOOR DEVICE INSTALLATION REQUIREMENTS Q <br /> HORN/STROBE y;y <br /> m w�Q0 <br /> 01 r7�20`om Q <br /> Q <br /> rm c� y C` eC W <br /> 75TH ST SE ar yrrnimm" FIRE ALARM DEVICE INSTALLATION REQUIREMENTS p Q NOT PERMITTED U F yCeoF w ha eRnc�Ei DIFFUSER HERE a' LJJ <br /> m m m ym c o -eox GRID LU N W <br /> 01 Ll 0 q > <br /> ec'Q� q ` m <br /> m m FA DEVICE CEILING SMOKE Q I� W <br /> DETECTOR 1, <br /> MINIMUM L <br /> 4 4 4 im im jC m m AWAY FROM NOT PERMITTED 2.. X <br /> HVAC DIFFUSERS HERE LLI <br /> SYSTEMINPUTS B D F H H S7 <br /> MOKE Q <br /> 1 Manual Fire Alarm Pull-Station 1 <br /> f 2 Smoke Detectors 2 <br /> 7/ a s J SHEET TITLE <br /> 3 Heat Detectors MAx HEIGHT ez"aF.F <br /> MIN HEIGHT 82"All ® l60 3 <br /> w 4 Unused 4 <br /> a 5 Unused 5 Y FIRE ALARM <br /> U) 6 Unused 6 ®� O = PROJECT DETAILS <br /> w <br /> Z T Fire Alarm AC Power Failure ♦ ♦ T fifi-A.F.F fi0-All pULL <br /> m8 Fire Alarrn System Low Battery 8 <br /> H A.F.F <br /> 9 Open Circuit 9 as" <br /> SHEET NUMBER <br /> 10 Ground Fault 10 <br /> A B C D E FIGIIH HNISHED 'F <br /> FA 0.0 <br />