Laserfiche WebLink
16 16 14 13 12 11 10 6 8 7 6 5 4 3 2 1 <br /> Window Schedule WINDOW AND DOOR NOTES <br /> VERTICAL ENS 0'-10'-4"0'•2" WINDOW <br /> STEP#6:APPLY SIDING SEE Type Mark Count TYPE Width Height U VALUE Comments 1. ALL EXTERIOR WINDOWS AND DOORS TO COMPLY WITH IRC R809 0 <br /> L WINDOW HEAD ELEVATION EXISTADD 24X48" 421LIDE <br /> LIDE 21-0" 2'•0" 0.30 2. WINDOWS AND DOORS SHALL BE CAPABLE OF RESISTING THE L <br /> FLASHING BEADING AW 80"X24" NING 2'•0" 2'•0" 0.30 3. WINDOWS AND SLIDING DESIGN WIND LOADS IGLASS)DOORS SHALL BE TESTED BY AN <br /> WITH SEALANT TO <br /> WINDOW HEAD FRAME. SL 24"x36" LIDE 3'-0" Y.O., 0.30 <br /> STEP 11•INSTALL 18" i HOUSE WRAP APPROVED INDEPENDENT LABORATORY AND BEARA LABEL <br /> PLUS SECTION OF ENSURE FASTENERS MOISTURE 10 mil. SL 38"X48" LIDE 3'-0" 4'-0" 0.30 IDENTIFYING THE MANUFACTURER,PERFORMANCE <br /> FLASHING FROM i ARE 12"ABOVE VAPOR BARRIER EXISTING 2"X4" SL 48"X48" LIDE 4'-0" 4'-0" 0.30 CHARACTERISTINCS,AND INSPECTION AGENCY TO INDICATE <br /> WR8-LEAVE WINDOW NAIL FLANGE. STUD SL 80"X24" 5'-0" 2'-0" 0.30 COMPLIANCE <br /> LOOSE AT BOTTOM / ADD'L 2"FILL SL 80"X48" LIDE 5'-0" 4'-0" 0.30 4. GARAGE DOORS SHALL BE TESTED IN COMPLIANCE WITH ASTM <br /> SO INSTALLATION E330 OR ANSIIDASMA 108 7 <br /> OF WIRE CAN TUCK / 5. WINDOW AND GLASS DOOR ASSEMBLIES SHALL BE ANCHORED <br /> O EXISTING MANUFACTURERS RECOMMENDATIONS TO ACHEIVE THE DESIGN = <br /> UNDER IT LATER. HEADER TO THE STRUCTURE IN ACCORDANCE WITH THE W <br /> PLYWOOD SHEATHING <br /> K WR8=WATER 6 PRESSURE SPECIFIED U <br /> RESISTIVE BARRIER r 6. TAPERED BUCKS ARE NOT ALLOWED K V) <br /> SECONDARY WEATHER BARRIER 7. GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE Z <br /> DECORATIVE 6" o PROVIDED WITH AMANUFACTURERS DESIGNATION SPECIFYING � <br /> WHO APPLIED THE DESIGNATION,TYPE OF GLASS AND THE R S <br /> WD.TRIM ENS SIDING PER ELEVATION v SAFETY GLAZING STANDARD <br /> BOARD 8. SAFETY GLAZING SHALL BE PROVIDED IN THE FOLLOWING <br /> SEALANT HAZARDOUS LOCATIONS: <br /> CAULKING A. GLAZING IN DOORS <br /> B. GLAZING ADJACENT TO DOORS WITHIN 60"OF THE FLOOR, <br /> SEALANT MILLED FIR SILL WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR,AND WITHIN <br /> STEP#7:APPLY 9" 24"OF THE HINGE SIDE OF A WALL LESS THAN 180 DEGREE <br /> U STRIP OF SELF FROM THE PLANE OF THE DOOR <br /> STEP 2:INSTALL DECORATIVE APPROVED SEALANT.USE CLOSED <br /> ADHESIVE MEMBRANE C. GLAZING IN WINDOWS THAT MEET ALL OF THE FOLLOWING: <br /> SELF ADHESIVE WD.TRIM 6 CELL BACKER ROD,IF GAP GREATER <br /> MEMBRANE(SAM) B" OVER WINDOW HEAD BOARD THAN 1M' a. LARGER THAN 9 SQ.FT. <br /> WRAPPING INTO FLASHING c.b. TO EDGE OVER 36OTTOM EDGE SFROM THE FLOOR <br /> THAN 18"FROM E FLOOR <br /> OPENING AND d. AND WITHIN 36"OF A WALKING SURFACE MEASURED <br /> LAPPING ONTO c EXISTING 2"X4" DRIP EDGE FLASHING <br /> / VERTICAL ENS STUD HORIZONTALLY <br /> WRB. SIDING D. GLAZING IN GUARDS AND RAILINGS <br /> INSTALL / ADD'L 2"FILL E. GLAZING IN WALLS CONTAINING OR FACING HOT TUBS, <br /> PREFORMED SAUNAS,BATHTUBS,SHOWERS OR OTHER WET AREAS <br /> PLASTIC SILL PAN / WHERE THE BOTTOM OF THE GLASS IS LESS THAN 60" <br /> WITH BACK DAM MEASURED VERTICALLY FROM THE FLOOR THAT IS LESS <br /> THAN 60"FROM THE WATERS EDGE MEASURED <br /> HORIZONTALLY <br /> O SECTION WDW SILL/HEAD O EXTERIOR DOOR HEAD F. GLAZING ADJACENT TO STAIRS AND RAMPS WHERE THE <br /> 2 1 1/2"=1'-0 3"=1'1" BOTTOM EDGE IS LESS THAN 36"ABOVE THE PLANE OF THE <br /> ADJACENTWALKIGN SURFACE <br /> G. GLAZING ADJACENT TO LANDINGS WHER ETHE GLAZING IS N STEP 3:INSTALL LESS THAN 36"ABOVE THE WALKING SURFACE AND WITHIN A <br /> 60"HORIZONTAL 180 DEGREE ARCH FROM THE BOTTOM Q <br /> g„ SELF ADHESIVE m <br /> MEMBRANE AT TREAD NOSING W <br /> JAMBS WRAPPING STOP H. EXCEPTIONS MAYAPPLY TO DECORATIVE GLAZING IN <br /> INTO OPENING AND <br /> LAPPING OVER AT CERTAIN LOCATIONS. Z LU <br /> 9" SILL 9. DOORS AND WINDOWS SHALL COMPLY WITH THE ENERGY CODE W W <br /> H I SIB PER WAL I REQUIREMENTS OUTLINED ON G3.00 <br /> WOOD TRIM *-.0r BLY — — 10.NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR W W <br /> I J1J 1/7'-5/8" EACH DWELLING UNIT.THIS DOOR E IDENTIFIED EN THE WIDTH <br /> H � W <br /> MUST BE SIDE HINGED AND PROVIDE A CLEAR OPENING WIDTH <br /> OF 32"MEASURED FROM THE FACE OF THE DOOR AT 90 <br /> CASING TRIM DEGREES TO THE FACE OF THE DOOR STOP WITH A HEIGHT NOT Z W <br /> PER OWNER LESS THAN 78"(6'-6').THIS DOOR SHALL BE READILY OPENED J H <br /> i FROM INSIDE THE DWELLING WITHOUT USE OF A KEY OR SPECIAL Q y <br /> SEAL CORNERS WINDOW PER KNOWLEDGE OR EFFORT.(IRC R 311.2) I--, <br /> WITH DOW SCHEDULE 11.EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE <br /> CORNING 758 CLEARANCE PROVIDED FROM BASEMENTS,ATTICS,AND EVERY HABITABLE n Z <br /> SILICONE SEALANT FOR HINGE: SLEEPING ROOM •- Q i 1/4"-3/8" 12.EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN <br /> G CONTINUOUS SHIM SPACE <br /> / DIRECTLY INTO A PUBLIC SPACE OR A YARD THAT OPENS TO THE <br /> PAN FLASHING PUBLIC WAY <br /> STEP#4:APPLY SIDING 13 EMERGENCY ESCAPE OPERABLE FROM THE INSIDE WITHOUT PE SPECIAL KNOWLEDGE,OR G n <br /> SEALANT TO HEAD 2X <br /> AND JAMBS BEFORE <br /> INSTALLING WINDOW USE OF KEYS OR TOOLS. <br /> 14.EMERGENCY ESCAPE AND RECUE OPENINGS SHALL BE A <br /> MINIMUM OF 5.7 SQUARE FEET OF CLEAR OPENING AREA WHICH <br /> DO NOT NAIL WINDOW HEAD TO OPENING-SEE SHALL BE A MINIMUM HEIGHT OF 24"AND A MINIMUM CLEAR <br /> \ i <br /> \ WINDOW MANUFACTURER'S, WIDTH OF 20" <br /> \ 15.EMERGENCY ESCAPE AND RECUE OPENINGS SHALL HAVE A SILL <br /> I INSTRUCTIONS--_ -_______ STEP#8:INSTALL WRB FROM BOTTOM UP O SIDE TRIM-WINDOW OQ DOOR FRAME HEIGHT NOT MORE THAN 44"ABOVE THE FLOOR <br /> ~ LAPPING PER MANUFACTURER'S 1 112,=1'-0" WIDTH T=1'-0" 16,EMERGENCY ESCAPE AND RECUE OPENINGS LOCATED BELOW <br /> F \ INSTRUCTIONS.AT WINDOW TUCK UNDER GRADE SHALL BE PROVIDED WITH A WINDOW WELL THAT SHALL E <br /> FLAP OF WRB SHOWN ON STEP#1 PER SCHEDULE NOT BE LESS THAN 9 SQUARE FEET WITH A HORIZONTAL 0 <br /> Sim PROJECTION NOT LESS THAN 36" F 0 <br /> 2 A. LADDERS SHALL BE PERMITTED TO ENCROACH NOT MORE .4 <br /> THAN 6"INTO THE REQUIRED WINDOW WELL DIMENSIONS 0 <br /> DOOR 8 FRAME <br /> PER SCHEDULE H t <br /> W W.,d.• N <br /> INSTALLA6"STRIp 3 Sim FLOOR TRANSITION <br /> THRESHOLD. H Z 03 in m <br /> INSTALL 1/16"HORSESHOE OF SELF ADHESIVE A910 uj ro 61 <br /> E SHIMS UNDER SILL NAIL MEMBRANE OVER x —Z m 3 <br /> FLANGE WMINDOW ANCHORS JAMBS AS SHOWN w y FLOOR FINISH FLOOR FINISH E Z Q 33 <br /> FROM NAIL FLANGE _ PER:SCHEDULE PER:SCHEDULE =Q m <br /> TO WRB a <br /> y c <br /> STEP#5:APPLY i III o_ c <br /> 6„ SELF ADHESIVE / ¢ m to <br /> MEMBRANE OVER <br /> NAIL FLANGE AT/ WINDOW HEAD __ c <br /> ° WINDOW DETAIL-Main O DOOR SILL INTERIOR Nci <br /> /2=' Q 9 3„=''-0" PERMIT APPROVAL STAMPS Cd <br /> Sim N <br /> STEP#9 7 F <br /> SEE DETAILS INCLUDING MANUFACTURER'S gg,10 <br /> DETAILS FOR FINISHING THE WALL WITH <br /> - WINDOW TRIM,RAIN SCREEN BATTENS AND <br /> SIDING <br /> C DOOR(SEE SCHEDULE.) WEATHER �� tn <br /> _ <br /> STRIP C <br /> G. <br /> NOTE--- _ CONCRETE PORCH W/ THRESHOLD <br /> ----_--NOON-- NOON-- SLOPE AWAY <br /> JOINT. 12"MAX HEIGHT <br /> NOTE: SLOPE AWAY FROM b" <br /> WHEN A WINDOW IN MASTIC <br /> W .W HEAD METAL FLASHING IS REQUIRED.INSTALL IT OVER THE WINDOW HEAD FLASHING PAPER 8 PLACE THE BLDG. FLOORING PER <br /> WATER RESISTANT BARRIER OVER THE FLANGE OF THE METAL FLASHING. SCHEDULE <br /> (2) FLASHING PAPER TO BE COATED VAPOR BARRIER,REINF.,GRADE"A"OR"B". SUBFLOOR — <br /> SEE <br /> STRUCTURAL PROJ.NO: <br /> (3) SELF-ADHESIVE MEMBRANE(SAM)SHALL BE'HENRY-BLUESKIN BREATHER' SRff J . <br /> `--- -- _------------------------- 22031 <br /> --------------------------- -- <br /> B WIDTH 2 <br /> PER SCHED. Ag.10 ISPERMIT <br /> DRAWN BY:RBC <br /> FLOOR JOIST CHECKED BY:MJG <br /> SEE ISSUE DATE:03/0312023 <br /> Son j', STRUCTURAL <br /> 0. 8 3 SCALE:As indicated <br /> Main Level REINF.CONC.PONY <br /> WALL O'-0" STRUCTURAL.) <br /> WINDOWS/DOOR <br /> STRUCTURAL.) d <br /> SCHEDULE o <br /> Sim DETAIL <br /> A <br /> 10 <br /> O WINDOW OPENING PREP. O WINDOW DETAIL-Garage © DOOR DETAIL AB10 O DOOR SILL ON CONCRETE EXTERIOR "D <br /> 1/2"=1'-0" <br /> 3'-1'-0" o <br /> 18"x12"DRAWINGS ARE112 SIZE SCALE NOTED A9.10 1 <br /> 13 12 <br /> 16 15 14 11 10 8 6 7 6 5 4 �� IF LINE DOES NOT MEASURE 1"SHEET IS NOT TO SCALE <br /> IF ANY DISCREPENCIES ARE FOUND,NOTIFY ARCHITECT IMMEDIATELY.VERIFY CONDITIONS AND DIMENSIONS IN FIELD. <br />