2 _. 3 4 5
<br /> Emerson ES Portable 11 DYKEMAN
<br /> D
<br /> APPROVED
<br /> Office of Community,Planning&Economic Development
<br /> Q�P)LA�N NI/N,GDEPARTMENT
<br /> Name- , � _DATE:I't_2-* II�,,/a((�==rl� M
<br /> REVEO V CDVICINITY MAP PROJECT INFORMATION GENERALNOTES ARCHITECTURAL SYMBOLS APR 25 2M D
<br /> CITY OF EVERETT
<br /> 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE THE WORK Permit Services
<br /> LEGAL DESCRIPTION OF ALL TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT.
<br /> SEC 18 TWP 28 RGE 02 BEG NW CDR SEC THE 1316.11FT TH S 759.62FT TPB TH 2. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ALL DETAIL NUMBER
<br /> W 716.14FT TH S TO S UN NW1/4 NW1/4 TH E ALG S W SO SUB 716.14FT TH IN DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. _ •
<br /> TIPS LESS CO RD&LESS S 20FT TO CITY OF EVERETT&LESS ADD'L RNV TO A3.0 SHEET NUMBER WHERE n(�
<br /> CITY OF EVERETT PER SWD REC AF 9104190362 DETAIL IS LOCATED
<br /> 3. CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF 89
<br /> V
<br /> THE WORK AS INDICATED ON ALL DRAWINGS.IF ERROR IN LAYOUT,
<br /> 526 DIMENSIONS,OR DETAILS ARE FOUND BETWEEN ARCHITECTURAL, 6467 REGISTERED D
<br /> STRUCTURAL,MECHANICAL,ELECTRICAL,CIVIL OR LANDSCAPE DRAWINGS ARCHITECT JU1V 14 20 4
<br /> CASINO RD CONTACT THE ARCHITECT IMMEDIATELY BEFORE PROCEEDING.
<br /> 84TH ST SE PARCEL NUMBER L _ _ D, SECTION NUMBER
<br /> 28051800201200 4 REQUIREMENTS FOR INSTALLATION OFCTION,MATERIALS ANDMATERIALS SHALL CONFORM AND BE AS 3 SEC ONSHEET NUMBER
<br /> S BOCATEDRE TI Y JAM S Ew e OF.4 T
<br /> w w GOVERNED BY THE EDITION OF THE CODE IDENTIFIED IN THE CODES AT OF WASH GTON i
<br /> 99 CO W SECTION OF THIS SHEET.
<br /> < Q 5. REFERENCING DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT _
<br /> C ¢_ = APPLICATION OF DRAWINGS OR DETAILS. DETAIL NUMBER
<br /> A2
<br /> SIZE (GROSS) _ J A7.5 SHEET NUMBER WHERE IDENTIFICATION:PROJECT C
<br /> 6. MATERIALS AND FINISHES LISTED ON INTERIOR AND EXTERIOR ELEVATIONS DETAIL IS LOCATED
<br /> yQ� 8.05 ACRES IN ADDITION TO MATERIALE FOR GENERAL INFORMATION
<br /> ANID FINISHES CONVENIENCE
<br /> IE OF OR SPECCOETRACTOR. Emerson ES
<br /> �\1 ELSEWHERE IN THE DOCUMENTS.
<br /> �O 88TH ST SE 7. HEIGHT DIMENSIONS ARE GIVEN FROM FINISHED FLOOR WHERE INDICATED, 101 DOOR NUMBER BASED Portable 11
<br /> GOVERNING CODES OR RELATIVE TO DATUM NOTED ON DRAWINGS. ON ROOM NUMBER
<br /> LU
<br /> ❑ 1. WAC 51-50INTERNATIONAL BUILDING CODE,2018 EDITION 8. N.I.C.EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS.CONTRACTOR FOR
<br /> J J IS RESPONSIBLE FOR COORDINATING INSTALLATION AND PERFORMING WORK <AA -WINDOW AND RELITE TYPE
<br /> d Q 2. WAC 51-52 INTERNATIONAL MECHANICAL CODE,2018 EDITION AS REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT
<br /> INSTALLATION. Everett Public
<br /> F 3. WAC 51-54 INTERNATIONAL FIRE CODE,2018 EDITION a
<br /> 2i 9. F.O.I.C.EQUIPMENT IS FURNISHED BY OTHERS AND INSTALLED AS PART OF NAME ROOM NAME Schools
<br /> 4. WAC 5157 UNIFORM PLUMBING CODE,2018 EDITION THIS WORK.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE
<br /> 101
<br /> S. WAC 51-11 WASHINGTON STATE ENERGY CODE WORK AS REQUIRED FOR INSTSALLATION. ROOM NUMBER 2018 EDITION AT
<br /> 10.DO NOT SCALE DRAWINGS:CONTACT ARCHITECT FOR ANY NEEDED
<br /> 92ND ST SE 6. 2018 EDITION NFPA STANDARD 72,13,13-D,13-R 2002 CLARIFICATION.
<br /> NORTH MAINTAIN
<br /> TYPE TAG 8702 7th Ave SE
<br /> 7. ICC/ANSI A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 11.CONTRACTOR SHALL INTAIN THE INTEGRITY OF THE VAPOR BARRIER
<br /> MEMBRANE AT THE FLOOR SLAB,WALLS,AND ROOF.BACKER ROD,SEALANT, ^
<br /> AND OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND / REVISION IDENTIFICATION Everett, WA 98208
<br /> ALL EXTERIOR DOORS,WINDOW PENETRATIONS,AND OTHER AREAS OF L�
<br /> POTENTIAL AIR INFILTRATION,INCLUDING STRUCTURAL,MECHANICAL,AND
<br /> ELECTRICAL PENETRATIONS.THE CONTRACTOR SHALL REPAIR ANY DAMAGE REVISION CLOUD PERMIT r1 SET
<br /> DRAWING INDEX TO VAPOR BARRIER OR REPLACE THEM PRIOR TO COVER AS APPROVED. 04/22/2024
<br /> PROJECT TEAM 12.WHERE EXTERIOR CONCRETE WALKS AND LANDINGS ABUT BUILDING,THEY
<br /> GENERAL SHALL BE SLOPED AWAY FROM THE BUILDING AS NOTED,BUT IN NO CASE This drawing is:
<br /> LESS THAN 1/8":12". 1.Copyright 2024 Dykeman,Inc.
<br /> G01 TITLE SHEET,PROJECT INFORMATION INDICATES DIRECTION OF 2.The Architect's Instrument of Professional Service.
<br /> B MAGNETIC NORTH 3.For use on this project only.Obtain Architect's B
<br /> OWNER STRUCTURAL ENGINEER ARCHITECTURAL Written permission for any other use or reproduction.
<br /> EVERETT PUBLIC SCHOOLS BRIGGS ENGINEERING,INC. As1.0 OVERALL SITE PLAN BUILDING CODE INFO NORTH PROJECT
<br /> 3900 BROADWAY PO BOX 140537 AS1.1 PARTIAL SITE PLAN-PORTABLES
<br /> OCCUPANCY: E
<br /> EVERETT,WA NNIF GARDEN CITY,ID BRI ELECTRICAL(REFERENCE ONLY) 2024-010
<br /> Contact: JENNIFER COLLINS Contact: DEAN BRIGGS TYPE OF CONSTRUCTION: VB,NONSPRINKLERED(PORTABLE)
<br /> Phone: (425)3864195 Phone: (208)87"200 El ELECTRICAL LEGEND AND DRAWING INDEX Permit#: B2404-056 ROLLED PLANS
<br /> Fax: Fax: - Eo.2 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES BLDG SO FT: 887,ONE STORY
<br /> Email: joollins@everettsd.org Email: bri sen ineedn E1.1 ELECTRICAL OVERALL SITE PLAN Site Address: 8702 7TH AVE PORTABLE 11
<br /> 1 @ r9 gg g g@msn.com E1.2 ELECTRICAL PARTIAL SITE PLAN BLDG HEIGHT: 15'-9" Owner: EVERETT SCHOOL DIST2
<br /> E1.3 LOW-VOLTAGE PARTIAL STfE PLAN
<br /> Tenant: EMERSON ELEMENTARY
<br /> E3.1 LOW-VOLTAGE FLOOR PLANS PORTABLE CLASSROOM CLUSTER: 2,661<6,000 SF App.Date: 4/25/2024
<br /> E7.1 ELECTRICAL DETAILS Permit Type: COMMERCIAL BUILDING
<br /> E7.2 ELECTRICAL DETAILS OCCUPANT LOAD: 45 - Subtype: MODULAR BUILDING/PORTABLE
<br /> E9.1 ELECTRICAL ONE-LINE DIAGRAMS Description: PORTABLE W/NEW FOUNDATION,RAMP -
<br /> ARCHITECT RAMPS AND LANDINGS E10.1 PANELSCHEDULES &LANDING
<br /> EVERETT FIRE DEPT.REVIEW 6��,� Date:
<br /> DYKEMAN WELCOME RAMP SYSTEMS WELCOME RAMPS,LANDINGS AND STAIRS DEFERRED SUBMITTALS APPROVED Reviewed By:
<br /> 1716 WEST MARINE VIEW DRIVE 2361 S 200TH ST
<br /> EVERETT,WA 98201-2098 SEATTLE,WA 98198 1 OF 1 STANDARD PLANS AND DETAILS 1 FIRE ALARM uired ❑APPROVED WITH CHANGES NOTED Office Set _lob Site Set
<br /> Additional Permits Are Req [I REVISE AND RESUBMIT
<br /> Contact: ZACH HAM Contact: TERRI GORDON 28 X 32 PORTABLE PLANS For This Project To Include: ❑REIECTED: _
<br /> ❑SEE ATTACHED CHECKLIST/HANDOUT •
<br /> Phone: (425)2593161 Phone: (866)935-9255 T-1 TITLE SHEET ❑ Plumbing ElS Sprinkler The issuance of a permit shall not PRINCIPAL IN CHARGE:I TJJ
<br /> Fax: (425)259-5242 Fax: A-1 FLOOR PLAN,DOOR AND WINDOW SCHEDULE ❑ Mechanical ©Fire Alarm be construed as authority to violate, PROJECT MANAGER: 1 ZAH
<br /> Email: zachh@dykeman.net Email: sales@weloomerampsystems.com A-2 SECTIONS,FASTENING SCHEDULE AND MATERIALS LIST cancel or set aside any provision of PROJECT ARCHITECT:
<br /> A-3 EXTERIOR ELEVATIONS Ip Electrical the Everett Fire Code or other JOB CAPTAIN: AM
<br /> A< DETAILS
<br /> A-5 REFLECTED CEILING PLAN AND DETAILS applicable regulations or laws.The
<br /> A M-1 MECHANICAL PLAN AND INFORMATION issuance of a permit based on DRAWING TITLE
<br /> E-1 ELECTRICAL PLAN AND INFORMATION construction documents and other 'A
<br /> ELECTRICAL ENGINEER F-1 PLANS,NOTES,MODULARFOUNDATION shall not the TITLE SHEET, PROJECT
<br /> HARGIS ENGINEERS THESE DOCUMENTS HAVE NOT BEEN of ial
<br /> from requiring the correction
<br /> APPROVED FOR THE ISSUANCE OF °f errors.
<br /> INFORMATION
<br /> 1201 THIRD AVE,STE 600 PUBLIC WORKS,MECHANICAL,FIRE
<br /> SEATTLE,WA 98101 SUPPRESSION,ELECTRICAL OR By: Da e: 2Si
<br /> Contact: JEFF HOOVER PLHDMBING PERMITS. DRAWING
<br /> Phone: (206)859-5396
<br /> Fax:
<br /> Email: jeif.hoover@hargis.biz
<br /> 1 2 3 4 5
<br />
|