Laserfiche WebLink
CLIENT: <br /> NASH k ASSOCIATES BEAM DESIGN DATA PROJECT: <br /> ARCHITECTS PER 2018 IBC DATK: <br /> NAME: <br /> Roof Loads: <br /> LL 25#/sf Tile Roof Loads: <br /> DL 15 #/sf LL 30#/sf <br /> Total 40#/sf DL 25#/sf <br /> Unless Noted Otherwise Total 55#/sf <br /> Floor Loads: Unless Noted Otherwise <br /> LL 40#/sf <br /> DL 10 #/sf <br /> Total 50#/sf <br /> Deck Loads: <br /> LL 60#/sf Paver Deck Loads: <br /> L SO # sf LL 60 <br /> #/sf <br /> Total 70#/sf DL 30#/sf <br /> Total 90#/sf <br /> Soi.L- 1500 PSF Min. <br /> Concrete: Per IBC 2018 <br /> Masonry Per IBC 2018 <br /> Steel: Per IBC 2018 <br /> Wood: Per IBC 2018 <br /> Nailing: Per IBC 2018 <br /> 4" Beam: Douglas Fir #2 <br /> fv = 180 <br /> fb = 900 PSI <br /> E = 1,600,000 <br /> 6" Beam: Douglas Fir #2 <br /> fv = 170 <br /> fb = 875 PSI <br /> E = 11300,000 <br /> Joists do Hem Fir #2 <br /> Rafters: fv = 150 <br /> fb = 850 PSI <br /> E = 1,300.000 <br /> Glu—Lam Beams: <br /> fv = 240 PSI <br /> fb = 2,400 PSI (reduced by size factor, CF*I{I) <br /> E = 1,800,000 <br /> 8003 118th Ave, NE. Kirkland, WA 98033 (425) 828-4117 <br /> WWW.NASH—ARCHITECTS.COM <br />