My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1722 100TH ST SW 2025-11-07
>
Address Records
>
100TH ST SW
>
1722
>
1722 100TH ST SW 2025-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2025 11:48:44 AM
Creation date
11/7/2025 10:48:25 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1722
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Minimum Requirement#l: Preparation of Stormwater site plan <br /> A Stormwater Site Plan/Building Site Plan has been prepared. <br /> Minimum Requirement#2: Stormwater Pollution Prevention Plans (SWPPP) <br /> SWPPP drawings and the required elements have been prepared and are a stand-alone <br /> document from this report. The BMPs indicated on the plans will be implemented during <br /> construction. Additional BMPs may be used on the site depending upon weather <br /> conditions. <br /> Minimum Requirement#3: Source Control of Pollution <br /> During construction SWPPP BMPs will be implemented,based on SMMWW Volume IV, <br /> Chapter 5,as shown on the SWPP plans. This project is not required to have source control <br /> BMPs after construction is completed. <br /> Minimum Requirement#4: Preservation of natural drainage and outfalls <br /> The proposed site development is not expected to have off-site drainage impacts. This <br /> project will disperse Stormwater runoff from the natural drainage location. On-site BMPs <br /> will be used to mitigate potential erosion issues and control runoff. For more information <br /> about BMP details and placement please refer to Section I of this report and Site Plans <br /> associated with this project. <br /> Minimum Requirement#5: On-site Stormwater Management <br /> The proposed project triggers Minimum Requirements 1 through 9 and is located inside <br /> the Urban Growth Area (UGA); therefore, the proposed project will use BMPs from List <br /> #2 of SMMWW Volume I, Table I-3.2 to mitigate stormwater runoff. <br /> BMPs for Lawn and Landscaped Areas: <br /> • BMP T5.13:Post-Construction Soil Quality and Depth is feasible. Existing topsoil <br /> will be stockpiled and used for final stabilization. <br /> BMPs for Roofs: <br /> • BMP T5.30: Full Dispersion is not feasible due the lack of 100 ft minimum flow <br /> path. <br /> • BMP T5.10A:Downspout Full Infiltration System is not feasible due to the shallow <br /> depth to water table. <br /> • BMP T730: Bioretention is not feasible due to the shallow depth to water table. <br /> • BMP T5.l OB: Downspout Dispersion Systems is feasible. Stormwater runoff from <br /> the proposed SFRs will use splash blocks. <br />
The URL can be used to link to this page
Your browser does not support the video tag.