Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: P2503-071 Description: Replace 3 Vanity Sinks, 1 Kitchen Sink <br /> Applied:3/26/2025 Approved: 3/27/2025 Site Address: 6916 RAINIER DR UNIT C <br /> Issued:3/28/2025 Finaled: 7/21/2025 City,State Zip Code: EVERETT,WA 98203-5186 <br /> Status: FINALED Applicant: Megan Wilaby <br /> Parent Permit: Owner: Megan Wilaby <br /> Parent Project: Contractor: OWNER <br /> Details: <br /> Replace 3 Vanity Sinks, 1 Kitchen Sink <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 4/25/2025 4/25/2025 PLUMB 08-FINAL** MASON CORRECTION see notes <br /> MORRISSEY REQUIRED <br /> Notes: <br /> 4/24/2025 9:08 AM Megan Wilaby <br /> 3 vanities&1 kitchen sink vanity-call megan 206-550-0671 <br /> Contact Name:Megan Wilaby <br /> Site Address:6916 RAINIER DR UNIT C <br /> Phone:2065500671 <br /> e-Mail:meganjenniferwilaby@gmail.com <br /> Leaks under kitchen,master and powder bath sinks.-Dishwasher 7/8 drain hose is trapped causing obstruction to flow.Needs to slope to disposal per <br /> UPC chap 7 and 8.-Hoses are kinked under kitchen and bathroom sinks stopping flow of water.-Downstairs powder bath sink has no water flow to <br /> faucet. <br /> 7/16/2025 7/16/2025 PLUMB 08-FINAL** MASON CORRECTION see notes <br /> MORRISSEY REQUIRED <br /> Notes: <br /> 7/15/2025 10:44 AM Megan Wilaby <br /> call megan for access 206-550-0671 <br /> Contact Name:Megan Wilaby <br /> Site Address:6916 RAINIER DR UNIT C <br /> Phone:2065500671 <br /> e-Mail:meganjenniferwilaby@gmail.com <br /> Main floor powder bath lav sink hot and cold water are crossed.Correction per UPC 417.5. <br /> T <br /> Printed: Monday, 17 November, 2025 1 of 2 F <br /> SUPERION <br />