My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2831 W MARINE VIEW DR REVIVE BOWLS 2025-12-02
>
Address Records
>
W MARINE VIEW DR
>
2831
>
REVIVE BOWLS
>
2831 W MARINE VIEW DR REVIVE BOWLS 2025-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 8:10:15 AM
Creation date
11/18/2025 9:30:00 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
2831
Tenant Name
REVIVE BOWLS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALLATION (2 of 2) Table <br /> Riser Height Needed Risers Required <br /> TELEGLIDE RISER(24 SERIES) 0-3-1/2" None(use adapter) <br /> INSTALLATION GUIDELINES 5"-23" SR24 <br /> Tools needed:7/16"Nut drivertool/bit(included),marker(included), Adapter >23"-38" LR24 <br /> tape measure and drill with 1/2"chuck.Jigsaw,circular saw or <br /> reciprocating saw will be needed if risers need to be cut. <br /> NOTE:To remove a component or adjust its position,the Upper <br /> Band Clamp needs to be loosened or removed using nut driver bit. <br /> Loosened clamps should be retightened to 5-8 ft lbs.of torque SR24 1 <br /> (same as a rubber no-hub coupling).The Lower Band Clamp is Adapter <br /> factory set and should not be adjusted or removed. Short Riser Riser <br /> Riser Assembly Instructions/Steps HeightNeeded <br /> 1. Set unit so the pipe connections line up with jobsite piping and Riser <br /> measure riser height needed from top of cover to finished grade. T_J <br /> See Table 1 to select risers needed. <br /> Alignment Mark ]'or 2" <br /> 2. Remove covers from adapters.Remove adapters from main unit. <br /> -- --- ----- - 5„ <br /> On a level surface,pre-assemble the risers and adapters,adjusting <br /> the components upwards or downwards to achieve the riser height LR24 Cut Line <br /> needed.Make sure to maintain minimum and maximum insertion Long Riser, —————— <br /> depths as shown in Figure 2. If components are too long,make a <br /> circular line around the sidewall with marker and cut with a power <br /> saw.The lowest cut line on the riser assembly will be 5"beyond the 4"(w/standard connections) <br /> riser height needed to allow for ideal insertion depth(See Figure 1). <br /> An alignment mark should be drawn 1-2"beyond the riser height (3"for GB-35 w/4"connections) <br /> needed(depending on connection size)which will align with the top <br /> of the base unit gasket.DO NOT cut the alignment mark.The Components Figure 1-Riser Measurements <br /> Adapters and risers should sit level with each other.Tighten upper <br /> clamps to keep riser/adapter assembly from shifting.Make <br /> alignment marks on the sidewalls at the top of all riser gaskets to aid <br /> final assembly. Cover <br /> 3. IMPORTANT:Before the next step, make sure both diffusers <br /> are installed inside the main unit at the appropriate locations. <br /> Check if there needs to be any flow control adjustment at the <br /> inlet diffuser(see general installation instructions). Adapter(shown) <br /> or Riser <br /> 4. Take apart riser assembly and clean all sidewalls and insides of <br /> gaskets to remove dust/debris.Install components into the main Gasket <br /> unit starting from the lowest riser and work your way up to - - - - - - - - - - - - - - - - - - <br /> finished grade.Maintain minimum and maximum insertion Upper Band Clamp <br /> depths for all components(see Figure 2).Tighten Upper Clamps 2-112"Minimum Insertion Depth (field adjustable) <br /> to specified torque after correctly positioning components.Riser <br /> assembly may need to be supported during backfill. Lower Band Clamp <br /> (factory set do- <br /> 4"Maximum Insertion Depth <br /> 5. If tilting of the adapter is required to be flush with grade,do so (into GB unit only) adjust or remove) <br /> not <br /> AFTER all clamps have been tightened with riser(s)/adaptor in a - - - - - - - - - - - - - - - - - GB Unit(shown) <br /> vertical and level position.Tilting is done using gasket flexibility. or Riser <br /> Tilting before tightening clamps may ruin a perfect gasket seal. <br /> Schier recommends tilting only the adapter versus the entire <br /> riser assembly to make sure your riser height and proper tank DepthsFigure 2-Insertion <br /> access is maintained. <br /> 6. If riser height conditions change after completing above steps, <br /> there may be room for adjustment.As long as minimum and <br /> maximum insertion depths are maintained(see Figure 2),the <br /> adapters/risers can be adjusted/cut as many times as necessary. <br /> When riser system installation is complete,see Leak/Seal Testing <br /> procedure if required(p3 of 5). <br /> . 0 MODEL NUMBER: DESCRIPTION:Polyethylene Grease Interceptor <br /> GB-35 35 GPM-35 gallon capacity <br /> - PART it:4020-001-XX DWG BY:B.Karrer DATE:10/08/2015 REV: 4 10/13/2017 ECO: <br /> 057-0840-02 page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.