My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-53 2025-12-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
3003 W CASINO RD BLDG 40-53 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:52:33 AM
Creation date
11/18/2025 10:24:24 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sprinkler 123d January 17, 2014 <br /> C <br /> ESFR PENDENT SPRINKLER <br /> N I KJ NG4 VK503 (K16.8) <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> DESIGN CRITERIA- UL <br /> (Also refer to Approval Chart 1 on page 123c.) <br /> cULus Listing Requirements: <br /> ESFR Pendent Sprinkler VK503 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest appropriate NFPA <br /> standards(including NFPA 13)for ESFR Pendent K16.8(242)Sprinklers,for: <br /> • Protecting rack storage of certain specified materials up to 35 ft (10.7 m) high in buildings with 40 ft (12.2 m) high ceilings with NO in-rack <br /> sprinklers. <br /> • Protecting rack storage of certain specified materials up to 40 ft(12.2 m)high in buildings with 45 ft(13.7 m) high ceilings with one row of in- <br /> rack sprinklers. <br /> • NFPA 13 indicates the following for ESFR pendent sprinklers having a 16.8 nominal K-Factor:Position the deflector a maximum of 14"(356 mm) <br /> and a minimum of 6" (152 mm)below the ceiling. <br /> • The minimum area of coverage allowed per sprinkler is 64 ft2(5.8 m2)per NFPA 13. <br /> Maximum Roof or Ceiling Slope: 2 in 12(167 mm/m or 9.5 degrees). <br /> Sprinkler Position:Approved for use only in the pendent position.Align the deflector parallel with the ceiling or roof. <br /> System Type:Wet systems only. <br /> Deflector Distance from Walls:At least 4"(102 mm)from walls,and no more than one-half the allowable distance permitted between sprinklers. <br /> Clearance from Deflector to Top of Storage:At least 36"(914 mm). <br /> Maximum Distance Between Sprinklers:The maximum area of coverage allowed per sprinkler is 100 ft2(9.3 m2)**. <br /> • For buildings over 30 ft(9.1 m)high,spacing between sprinklers and/or branch lines must be from 8 to 10 ft(2.4 to 3.1 m)". <br /> • For building heights up to 30 ft(9.1 m),the spacing allowed between sprinklers and/or branch lines is 8 to 12 ft(2.4 to 3.7 m), provided the <br /> area covered per sprinkler does not exceed the maximum 100 ft2(9.3 m2)allowed**. <br /> ""Refer to the Installation Standards for permissible deviations from the maximum sprinkler/branch line spacing rules above,to eliminate obstruc- <br /> tions created by trusses and bar joists when using ESFR sprinklers. <br /> Minimum Area of Coverage:The minimum area of coverage allowed per sprinkler is 64 ft2(5.8 m2). <br /> Note: If the ceiling is beam and girder or panel construction, locate sprinklers in the bays rather than under the beams. <br /> IMPORTANT.Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Viking ESFR Pendent <br /> Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest standards <br /> of VdS, NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, <br /> ordinances, and standards whenever applicable. <br />
The URL can be used to link to this page
Your browser does not support the video tag.