My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6617 ASSOCIATED BLVD AMAZON 2025-12-01
>
Address Records
>
ASSOCIATED BLVD
>
6617
>
AMAZON
>
6617 ASSOCIATED BLVD AMAZON 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 8:18:17 AM
Creation date
11/18/2025 10:34:31 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6617
Tenant Name
AMAZON
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SMITH FIRE SYSTEMS, INC <br /> 1106 54TH AVENUE EAST TACOMA,WASHINGTON 98424 <br /> (253)926-1880 Fax(253)926-2350 <br /> SMITH FIRESYSTEMS CONTR. REG. NO.SMITHFS1360T <br /> GENERAL/HYDRAULIC CALCULATION INFORMATION SHEET <br /> PROJECT NAME: AMAZON DWS5- PHASE 1 JOB NO. : N125004 OWNER: <br /> DATE: 4/7/2025 AMAZON <br /> ADDRESS: 6617 ASSOCIATES BLVD. BY: SHANE CHALLENDER AHJ : <br /> EVERETT,WA.98203 CITY OF EVERETT <br /> SYSTEM DESIGNATION: SYSTEM#4 <br /> DESIGN PER: NFPA 13(2019 EDITION) <br /> OCCUPANCY CLASSIFICATION: STORAGE <br /> STORAGE DESCRIPTION: CEILING HEIGHT: 36'-6" <br /> COMMODITY: CLASS I-V,GROUP A PLASTICS PEAK SPRINKLER ELEVATION: 35'-10" <br /> ROOF SLOPE: .25/12 <br /> STORAGE CONFIGURATION: NO OPEN TOP CONTAINERS <br /> SINGLE, DOUBLE&MULTIPLE TOTAL SPRINKLERS CALCULATED: 12 <br /> MAX AREA OF COVERAGE PER SPRINKLER: 100 SQ.FT <br /> STORAGE HEIGHT: 30' MAX DISTANCE BETWEEN SPRINKLERS: 10' <br /> MAX CEILING HEIGHT: 40' SPRINKLER MANUFACTURER: <br /> AISLE WIDTH: 8' K-FACTOR: 16.8 <br /> NFPA TABLE: 23.5.1-23.6.1 MODEL: ESFR <br /> SYSTEM TYPE: WET TEMPERATURE: 165 <br /> ENCAPSULATED: NO RESPONSE TYPE: FAST <br /> SOLID SHELVES: YES <br /> COMBUSTIBLE LIQUIDS: FIRE PUMP: Y <br /> HAZARDOUS MATERIAL: IRATED CAPACITY OF PUMP: 1500 GPM AT 65 PSI <br /> DESIGN AREA <br /> MOST DEMANDING 12 SPRINKLERS AT 52 PSI MIN. END HEAD PRESSURE <br /> ALLOWANCES INCLUDED IN CALCULATIONS: ADDED AT: <br /> OUTSIDE HOSE 250 GPM SOURCE <br /> WATER SUPPLY: ELEVATION OF TEST: FT. ELEVATION OF LEVEL 1: 0 FT. MAIN DRAIN TEST: <br /> STATIC 97 PSI DATE OF TEST: 8/20/2024 S: R: <br /> RESIDUAL 56 PSI DATA PROVIDED BY: CITY OF EVERETT INSPECTORS TEST: <br /> FLOW 3,771 GPM LOCATION OF TEST: MAIN ALONG ASSOCIATES BLVD. TRIP TIME: <br /> WET SYSTEM NUMBER NOTES: <br /> AREA SQ. FT. SPRINKLERS <br /> TOTAL: <br /> ---------------------------- <br /> MOST DEMANDING AREA:SYS.4 : Ex 1feS WASHINGTON STATE <br /> P CERTIFICATE OF COMPETENCY <br /> MOST DEMANDING 12 SPRINKLERS AT 52 PSI 12/31/25 <br /> � FIRE SPRINKLER SYSTEMS <br /> BASE OF RISER: 1461 GPM REQUIRED AT 120.4 PSI ; Bassione Sean Van Soest <br /> �SUMMARY: 1711 GPM REQUIRED AT 73.1 PSI ; 6027-0110-C Level Smith Fire Systems, Inc. <br /> AT CONNECTION TO SOURCE ; SMITHF51360T <br /> (INCLUDING 250 GPM FOR HOSE STREAMS) ; 04/07/2025 ; <br /> signafu06 Date <br /> L............................A <br />
The URL can be used to link to this page
Your browser does not support the video tag.