My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-26 2025-12-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
3003 W CASINO RD BLDG 40-26 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:37:03 AM
Creation date
11/18/2025 11:50:13 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KWIK HUS-EZ Screw Anchor Technical Supplement <br /> Table 28- Hilti KH-EZ, KH-EZ P, KH-EZ PM,KH-EZ PL,KH-EZ C and KH-EZ CRC steel screw <br /> anchor factored resistance in the top of uncracked concrete over metal deck'2,3,4,5 <br /> Nominal Tension-N Shear-V <br /> anchor Effective Nominal f'�=20 MPa f'�=30 MPa f' =20 MPa f'.=30 MPa <br /> diameter embed. embed. (2,9O0psi) (4,350 psi) (2,900 psi) (4,350 psi) <br /> in. in.(mm) in.(mm) Ib(kN) Ib(M) Ib(M) Ib(kN) <br /> 1/4 1.18 1-5/8 665 750 805 985 <br /> (30) (41) (3.0) (3.3) (3.6) (4.4) <br /> 3/8 1.11 1-5/8 980 1,200 980 1,200 <br /> (28) (41) (4.4) (5.3) (4.4) (5.3) <br /> Table 29- Hilti KH-EZ, KH-EZ P, KH-EZ PM,KH-EZ PL,KH-EZ C and KH-EZ CRC steel <br /> anchor factored resistance in the top of cracked concrete over metal deck'2,3,4,5 <br /> Nominal Tension-N, Shear-Vr <br /> anchor Effective Nominal f'c=20 MPa f'c=30 MPa f'c=20 MPa f =30 MPa <br /> diameter embed. embed. (2,9O0psi) (4,350 psi) (2,900 psi) (4,350 psi) <br /> in. in.(mm) in.(mm) Ib(M) Ib(kN) Ib(kN) Ib(kN) <br /> 1/4 1.18 1-5/8 340 385 565 690 <br /> (30) (41) (1.5) (1.7) (2.5) (3.1) <br /> 3/8 1.11 1-5/8 510 620 685 840 <br /> (28) 1 (41) 1 (2.3) (2.8) (3.0) (3.7) <br /> 1 See PTG Ed.19 Section 3.1.8 to convert design strength value to ASD value. <br /> 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. <br /> 3 Apply spacing,edge distance,and concrete thickness factors in tables 20 and 21 as necessary. Compare to the steel values in table 22. <br /> The lesser of the values is to be used for the design. <br /> 4 Tabular values are for normal-weight concrete only. For lightweight concrete multiply design strength by Aa as follows: <br /> for sand-lightweight,A.=0.68;for all-lightweight,ha =0.60 <br /> 5 Tabular values are for static loads only.Seismic design is not permitted for uncracked concrete.For seismic tension loads,multiply <br /> cracked concrete tabular values in tension by the following reduction factors: <br /> 1/4-inch diameter-a =0.60 <br /> 3/8-inch diameter-ar,,,.,,=0.75. <br /> No reduction needed for seismic shear.See PTG Ed.19 Section 3.1.8 for additional information on seismic applications. <br /> KWIK HUS-EZ SCREW ANCHOR-July 2020 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.