My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-26 2025-12-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
3003 W CASINO RD BLDG 40-26 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:37:03 AM
Creation date
11/18/2025 11:50:13 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KWIK HUS-EZ Screw Anchor Technical Supplement <br /> Table 32—Hilti KH-EZ, KH-EZ P, KH-EZ PM, KH-EZ PL, KH-EZ C and KH-EZ CRC allowable loads installed <br /> in top-of-grout-filled concrete masonry walls or horizontal members of wall openings'2,1 <br /> Shear lb <br /> Nominal Minimum Minimum <br /> Load direction <br /> anchor embedment Edge Critical end Parallel Perpendicular <br /> diameter depth distance' spacings distance6 Tension to edge of to edge of <br /> in. in. in. in. in. lb masonry wall masonry wall <br /> 15/8 1 1/2 205 180 135 <br /> 3 3/4 205 275 275 <br /> 1/4 2 1/2 1 1/2 4 4 355 345 155 <br /> 3 3/4 390 415 330 <br /> 15/8 11/2 245 345 175 <br /> 3 3/4 245 345 345 <br /> 3/8 3 1/4 1 1/2 6 6 465 490 200 <br /> 3 3/4 540 800 625 <br /> 21/4 13/4 390 460 200 <br /> 3 3/4 610 525 500 <br /> 1/2 4 1/4 1 3/4 8 8 540 885 245 <br /> 3 3 4 750 1275 550 <br /> 5/8 5 1 3 4 10 10 975 930 245 <br /> 3 3 4 1 975 2190 630 <br /> 3 4 6 1 4 1 3 3 4 12 12 1 975 2430 630 <br /> Table 33—Hilti KH-EZ, KH-EZ P, KH-EZ PM, KH-EZ PL, KH-EZ C and KH-EZ CRC allowable loads installed <br /> in end-of-wall or vertical members of wall openings',' <br /> Shear lb <br /> Nominal Minimum Minimum <br /> Load direction <br /> anchor embedment Edge Critical end Parallel Perpendicular <br /> diameter depth distance' spacings distance Tension to edge of to edge of <br /> in. in. in. in. in. lb masonry wall masonry wall <br /> 15/8 11/2 360 525 205 <br /> 1/4 3 3/4 4 4 380 595 585 <br /> 2 1/2 1 1/2 590 610 225 <br /> 3 3/4 755 635 585 <br /> 15/8 11/2 355 725 215 <br /> 3/8 3 3 4 6 6 465 1010 825 <br /> 31/4 112 565 875 240 <br /> 3 3 4 1020 1195 1050 <br /> 21/4 13/4 500 855 260 <br /> 3 3/4 525 1100 1050 <br /> 1/2 41/4 13/4 8 8 650 925 280 <br /> 3 3/4 1150 1240 1050 <br /> 5/8 5 3 3/4 10 10 1605 2215 1050 <br /> 3 4 1 6 1 4 1 3 3 4 12 1 12 1 1865 2550 1 1050 <br /> 1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi.Concrete masonry <br /> units may be lightweight,medium-weight or normal-weight conforming to ASTM C90. Allowable loads are calculated using safety factor of 5. <br /> 2 See figure 6 and 7 for allowable anchor installation locations on the top of grout-filled concrete masonry walls.Anchors may not be installed <br /> within one inch of a vertical joint. See figure 7 for anchor installation locations in end-of-wall and vertical members of wall openings. <br /> 3 Anchors may not be installed within 1-1/4"in any direction of a head joint. <br /> 4 For load values at edge distances between listed values linear interpolation is permitted. <br /> 5 Critical spacing equals minimum spacing. <br /> 6 Minimum end distance applicable to top-of-wall and end-of-wall and does not apply for wall openings such as windows. <br /> KWIK HUS-EZ SCREW ANCHOR-July 2020 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.