My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-26 2025-12-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
3003 W CASINO RD BLDG 40-26 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:37:03 AM
Creation date
11/18/2025 11:50:13 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CO® Worldwide www.tyco-fire.com <br /> Contacts <br /> Model ESFR-17 <br /> 16.8 K-factor Upright Sprinkler <br /> Early Suppression, Fast Response <br /> IMPORTANT • Most encapsulated or non-encap- <br /> sulated common materials including ; <br /> Refer to Technical Data Sheet cartoned, unexpanded plastics <br /> TFP2300 for warnings pertaining to . Cartoned, expanded plastics <br /> regulatory and health information. <br /> • Some storage arrangements of rub- <br /> Always refer to Technical Data ber tires and roll paper <br /> Sheet TFP700 for the "INSTALLER For more specific criteria, see Table A <br /> WARNING" that provides cautions and the applicable design standard. <br /> with respect to handling and instal- <br /> lation of sprinkler systems and com- The Model ESFR-17 Upright Sprin- <br /> ponents. Improper handling and klers provide the system designer with <br /> installation can permanently damage an upright option to the traditional <br /> a sprinkler system or its compo- pendent ESFR Sprinklers.With a K-fac- <br /> nents and cause the sprinkler to fail for of 16.8, Model ESFR-17 Sprinklers <br /> to operate in a fire situation or cause provide system designers with hydrau- <br /> it to operate prematurely. lic and sprinkler placement options not <br /> presently available to traditional ESFR - <br /> Sprinklers having a K-factor of 14.0. In <br /> Scan the OR code or enter the URL particular, the Model ESFR-17 Upright <br /> in a web browser to access the most Sprinklers are designed to operate at <br /> up-to-date electronic version of this substantially lower-end head pressures <br /> document. Data rates may apply. compared to ESFR Sprinklers with 14.0 Sprinkler <br /> K-factor. This feature offers flexibility <br /> r. when sizing system piping and posi- Identification <br /> 7 .;1 tioning the system piping with respect <br /> r 1 to the ceiling. Number (SIN) <br /> ��- See Table A <br /> — 1 <br /> The Model ESFR-17 Upright Sprinklers Technical <br /> ■ 1 described herein must be installed and <br /> IL maintained in compliance with this Data <br /> document, as well as with the appli- <br /> ■A cable standards of the National Fire <br /> Protection Association(NFPA),in addi- Approvals <br /> �■1��J FM Approved <br /> tion to the standards of any authorities EAC Approved <br /> docs.jci.com/tycofire/tfp316 having jurisdiction, such as FM Global. <br /> Failure to do so may impair the perfor- Finish <br /> mance of these devices. Natural Brass <br /> General The owner is responsible for main- Physical Characteristics <br /> taining their fire protection system Frame .............................Brass <br /> Description and devices in proper operating con- Deflector.....................Stainless <br /> copper <br /> dition. Contact the installing contrac- Compression Screw.......... Stainless Steel <br /> The TYCO Model ESFR-17 Upright- g Hook............................MONEL <br /> for or product manufacturer with any Strut.............................MONEL <br /> Sprinklers are Early Suppression, Fast questions. Link Assembly................Solder,Nickel <br /> Response (ESFR) sprinklers with a Button............ ...Brass <br /> nominal K-factor of 16.8.The sprinkler In all cases, the appropriate NFPA or Sealing Assembly..Beryllium Nickel w/TEFLON <br /> assembly is shown in Figure 1.They are FM Global installation standard must Ejection Spring.................. INCONEL <br /> suppression mode sprinklers that are be referenced to ensure applicabil- Deflector Nut........................Brass <br /> especially advantageous as a means ity and to obtain complete installa- Additional Technical Data <br /> of eliminating in-rack sprinklers when tion guidelines. The general guidelines See Table A <br /> protecting high-piled storage. in this data sheet are not intended to <br /> Model ESFR-17 Sprinklers are primarily provide complete installation criteria. <br /> used for ceiling-only sprinkler protec- <br /> tion of, but not limited to,the following <br /> storage applications: <br /> Page 1 of 4 DECEMBER 2022 TFP316 <br />
The URL can be used to link to this page
Your browser does not support the video tag.