My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-26 2025-12-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
3003 W CASINO RD BLDG 40-26 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:37:03 AM
Creation date
11/18/2025 11:50:13 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TOLBraceTM Seismic Bracing Calculations V8.8.142 <br /> Contractor: Viking Fire Protection <br /> Project Address: 40-26 Traveler Address: 3434 1st Ave S <br /> Seattle,WA 98134 <br /> Boeing Ev Pow,nfvBustpossftd6ode <br /> Phone: 206-622-4656 <br /> WA License: VIKINAS373NT <br /> Job#WO-13390 Calculations based on 2019 NFPA Pamphlet#13 <br /> Brace Information TOLCOTM Brace Components <br /> Maximum Brace Length 7'0" (2.134 m) TOLCOTM Component Listed Load Adjusted Load <br /> Diameter of Brace 1 Fig. 1001 Clamp 1470 Ibs(667 kg) 1470 Ibs(667 kg) <br /> Fig.980-3/8"Universal Swivel 3360 Ibs(1524 kg) 3360 Ibs(1524 kg) <br /> Type of Brace Sch.40 Fig.828 Across 3/8"Thick Flang 3340 Ibs(1515 kg) 3340 Ibs(1515 kg) <br /> 60° Min. *Calculation Based on CONCENTRIC Loading <br /> Angle of Brace *Please Note:These calculations are for TOLCOTM components only.Use of any <br /> other components voids these calculations and the listing of the assembly. <br /> Least Rad.of Gyration 0.42"(11 mm) <br /> Seismic Brace Assembly Detail <br /> L/R Value 200 <br /> Max Horizontal Load 1604 Ibs (728 kg) - <br /> TOLCO FIG.828 <br /> Other Requirements - FM Approved Loads = <br /> Fastener Information <br /> NFPAT e F TOLCO FIG. 1001 <br /> 0 <br /> Orientation to Connecting Surface YP <br /> Fastener <br /> TOLCO FIG.980 <br /> Type Fig.828 Across 3/8"Thick Flange <br /> Diameter N/A <br /> BRACE PIPE <br /> Length N/A <br /> Maximum Load 3340 Ibs(1515 kg) <br /> Brace Identification on Plans La1 <br /> Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way[ ] <br /> Sprinkler System Load Calculation (Fpw= CpWp) <br /> C = 0.7714 Sds=1 .102 <br /> Diameter Type Length Total Length Weight Per Unit Length Total Weight <br /> 4"(100 mm) Sch. 10 24.25 ft(7.4 m) 24.25 ft(7.4 m) 11.78 lb/ft(17.53 kg/m) 286 Ibs(130 kg) <br /> 2.5"(65 mm) Sch.40 115.5 ft(35.2 m) 115.5 ft(35.2 m) 7.89 lb/ft(11.74 kg/m) 911 Ibs(413 kg) <br /> 2"(50 mm) Sch.40 28 ft(8.5 m) 28 ft(8.5 m) 5.13 Ib/ft(7.63 kg/m) 144 Ibs(65 kg) <br /> Subtotal Weight 1341 Ibs(608 kg) <br /> Wp(incl. 15%) 1542 Ibs(700 kg) <br /> Main Size Type/Sch. Spacing(ft) Total(Fpw) 1190 Ibs(540 kg) <br /> 4" Sch.10 24.25 Maximum Fpw per 18.5.5.2(if applicable) 1307 lb(592 kg) <br /> fTOLBraceTM Version 81 Use of TOLBraceTM is subject to terms and conditions per the end user license agreement <br />