My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY 2025 ZAP ENERGY 2025-12-02
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY 2025 ZAP ENERGY 2025-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 8:24:33 AM
Creation date
11/18/2025 11:55:57 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Year
2025
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SmartOne° CLASS B Ror O Kldde <br /> Addressable Contact Input Device Fire Systems <br /> K-76-703 Effective: February 2021 <br /> FEATURES <br /> • Monitors N.O.or N.C. Unpowered Contacts Maximum 200 Ohm Loop Resistance(both conductors) <br /> • Full Digital Communications cULus Listed <br /> • Output for Remote LED(Customer-Supplied) FM Approved <br /> • CLASS B Initiating Device Circuit <br /> DESCRIPTION <br /> The SmartOnee Addressable Contact Input Device (AI) is an intelligent ❑�°, <br /> field device with its own microprocessor and memory which interfaces to ® + <br /> all standard contact type fire alarm devices.The Initiating Device Circuit ® o EartOsa + <br /> (IDC)is wired as one CLASS B NFPA 72 circuit. ® +€ -XITZ,—,m, <br /> The type of contact monitored is selectable through a jumper to monitor <br /> N.O.(Normally Open)or N.C.(Normally Closed)devices. °°^T°s•V <br /> FIELD PROGRAMMING a.„. R <br /> CLASS B Addressable Input modules are interchangeable with existing <br /> Addressable Input modules in the field. The module's Signaling Line <br /> Circuit (SLC) address is set in the same manner as all SmartOne SPECIFICATIONS <br /> devices. System address, owner location message and reporting type Operating Voltage Range: 24VDC(nominal) <br /> are programmable via the compatible control unit configuration software Device Current: 580 pA Max <br /> program.The system address is a 3-digit number that uniquely identifies (for all operating conditions) <br /> each device. The owner location message is a 40-character, alpha <br /> numeric message that describes the location of the device.The reporting Operating Temperature Range: -31 TO 151IF(-35 to 66*C) <br /> type is assigned to the Al based on the functionality of the device being Operating Humidity Range: 0-95%RH,non-condensing <br /> monitored. <br /> SUPERVISION Environment: Indoor Use Only,Dry Locations <br /> The Al continuously monitors the integrity of the following: Construction: Flame Retardant ABS <br /> • Continuity of contact interface wiring Shipping Weight: 3.45 oz.(98 g) <br /> • Device/panel communications Compatible Electrical Boxes: North American 2-1/2 in.(64 mm)Deep <br /> • Power/communications voltage 1-Gang Box with Metal Cover or Stan- <br /> Internal power supply dard 4-in.Square Box 1-1/2-in.(38 mm) <br /> • Memory data Deep with 4-in.Metal Cover. <br /> STATUS LED Initiating Device Circuit NFPA 72 CLASS B Wiring <br /> A remote status LED may be connected to the Al. (for Normally Open Al) <br /> EOL Resistor Value: 10KS2 <br /> ORDERING INFORMATION <br /> Max.Circuit Resistance: 20052 (per IDC) <br /> Description Part Number 10052(per conductor) <br /> 11111101111110OXASS B Addressable Input Module 70-610001-001 Max.Circuit Capacitance: 0.1µF <br /> Note:P/N 70-610001-001 includes: Recommended Wire Type: Twisted,unshielded,low-capacitance, <br /> — CLASS B Addressable Input Module fire-alarm wire <br /> — Installation Bracket <br /> — (2)End-of-Line Resistors COMPATIBLE CONTROL UNITS <br /> End-of-Line Resistors(10) 70-411001-005 Fire Alarm Control Current Product Legacy Product <br /> Installation Bracket 06-237614-001 Unit(FACU)Type <br /> Single Loop ARIESkSLX ARIES° <br /> FENWALNETT"6000 <br /> MICRO SLX <br /> PEGAsys T"* <br /> FENWALNET""2000* <br /> Multi Loop ARIES®-MLX ARIES°NETLink <br /> FenwaINET""8000-ML <br /> EXPORT INFORMATION(USA) MICRO MLX <br /> Jurisdiction:EAR PEGAsys* <br /> US ECCN:EAR99 FENWALNET"2000* <br /> This document contains technical data subject to the EAR. <br /> *FACUs running software revision 82.4 are compatibility-tested but not <br /> SmartOne and ARIES are registered trademarks of Kidde-Fenwal,Inc.,or its parents, agency listed with the device(s)in this data sheet. <br /> subsidiaries or affiliates. <br /> This literature is provided for informational purposes only.KIDDE-FENWAL, INC.believes this data to be accurate,but it is pub- <br /> lished and presented without any guarantee or warranty whatsoever. KIDDE-FENWAL, INC.assumes no responsibility for the <br /> product's suitability for a particular application.Product features specified are only applicable when the fire suppression system is Ashland,MA 01721 USA <br /> correctly designed,installed,maintained and serviced by trained,authorized Kidde Fire Systems distributors as per the applicable Tel:(508)881-2000 <br /> design,installation,operation,and maintenance manuals.If you need more information on this product,or if you have a particular kiddefiresystems.com <br /> problem or question,contact:KIDDE-FENWAL,INC.,Ashland,MA 01721 USA,Telephone:(508)881-2000. <br /> K-76-703 Rev AA ©2021 Carrier <br />
The URL can be used to link to this page
Your browser does not support the video tag.