My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY 2025 ZAP ENERGY 2025-12-02
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY 2025 ZAP ENERGY 2025-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 8:24:33 AM
Creation date
11/18/2025 11:55:57 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Year
2025
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CS-24 & C H S-24 <br /> POTTERIndoor Wall Mount Colored Lens <br /> The Symbol of Protection Strobe and Horn/Strobe Series <br /> Wiring Diagrams <br /> UL Listed <br /> UL Listed Control <br /> Control Panel Signal Signal <br /> Signal Signal S+ S+ S- H+ H- S+ S+ S H+ H- <br /> Panel <br /> S+ S+ S- H+ H- S+ S. S- H+ H_ Supervised <br /> Supervised If& 0 0 0 0 Signal Circuit <br /> Signal Circuit \ + <br /> \ + L END LINE <br /> END OF LINE RESISTOR <br /> RESISTOR <br /> \ + <br /> END OF LINE <br /> RESISTOR <br /> NOTES. <br /> • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. <br /> However,use of the AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn and/or mute the horn. <br /> • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050)AND/OR <br /> AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE <br /> DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. <br /> Architect and Engineering Specifications <br /> The audible and/or visible signal shall be Potter Colored Lens Series or approved equal and shall be listed by Underwriters Laboratories Inc.per ANSFUL <br /> 1638 and ANSI/UL 464 and shall have compliance with the polar dispersion requirements of ANSFUL 1971.The notification appliance shall also be listed <br /> with the California State Fire Marshal(CSFM). <br /> The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater as measured in an anechoic chamber.The <br /> signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair ofpower <br /> wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. <br /> Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control <br /> panel. <br /> The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of l Hz or up to 2 Hz regardless of power input voltage.The <br /> appliance shall have an operating current of 74mA or less at 24 VDC for the 15Cd strobe circuit. <br /> The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals <br /> with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The <br /> unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models. <br /> The appliance shall be capable of testing supervision without disconnecting wires.Also,the appliance shall be capable of mounting to a surface back box. <br /> The unit shall also be able to verify voltage at the unit without removing unit. <br /> Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com <br /> ISO 9001:2008 1 DESIGNING,MANUFACTURING, <br /> 8 DISTRIBUTING QUALITY SYSTEMS 8830055-REV B • 10/14 PAGE 4 OF 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.