Anvi © Bea m C La m ps rts <br /> :,00, M C, <br /> Engineered Solutions <br /> Surge Restrainer <br /> Material Specifications <br /> Fig.AF310 <br /> Size Range <br /> 1"through 2"Figure 69,Swivel Ring Hanger <br /> Material <br /> Carbon steel <br /> ' Finish <br /> Pre-Galvanized per ASTM A653 <br /> Restrainer Service <br /> Prevents vertical movement of horizontal <br /> sprinkler piping from thrust loads due to sprinkler <br /> activation.The surge restrainer is intended to <br /> be installed with Anvil's Figure 69 Swivel Ring <br /> Hanger. <br /> O Restraint service <br /> C US May be installed as part of a branch line seismic <br /> LISTED restraint assembly perthe requirements of NFPA <br /> 13.The surge restrainer is intended to be installed <br /> with Anvil's Figure 69 Swivel Ring Hanger. <br /> Approvals <br /> cULus Listed(UL 203 and UL 203a).Complies with <br /> 'Is"Rod = the hanging and restraint requirements listed in <br /> Fig.AF310 Fig.69 Knurl Nut = NFPA 13. <br /> Fig.69 fi fi Features <br /> o ` One universal size accommodates Fig.69 sizes <br /> 1"through 2". <br /> Branch Pipe <br /> Simple design allows for quick installation on <br /> existing sprinkler systems <br /> 0 Installation Instructions <br /> Surge Restraint Seismic Restraint Snap surge restrainer onto the Fig.69 <br /> Assembly Assembly knurl nut. <br /> Loads(Lbs) • Dimensions(In) •Weight(Lbs) The gap between the surge restrainer and <br /> service pipe shall not exceed'/8". <br /> Service Rod UL Max Seismic Restraint Load Approx. Fire Protection applications shall also be <br /> Pipe Size Size (UL 203a) Weight/100 <br /> 1 thru 2 % 300 4 installed per the requirements of NFPA 13. <br /> Notes Ordering <br /> ASC Engineered Solutions1m brand bracing components are designed to be compatible ONLY Specify figure number and description. <br /> with other ASC Engineered Solutions brand bracing components,resulting in a Listed seismic <br /> bracing assembly.Updated UL listing information may be viewed at www.ul.com <br /> Disclaimer <br /> ASC Engineered Solutions does not provide any warranties and specifically disclaims any liability ANVIL. <br /> whatsoever with respect to ASC Engineered Solutions bracing products and components that <br /> are used in combination with products,parts or systems not manufactured or sold by ASC An ASC Engineered Solution <br /> Engineered Solutions.In no event shall ASC Engineered Solutions be liable for any incidental, <br /> direct,consequential,special or indirect damages or lost profits where non-ASC Engineered <br /> Solutions bracing components have been,or are used. <br /> PROJECT INFORMATION APPROVAL STAMP <br /> Project: ❑Approved <br /> Address: ❑Approved as noted <br /> Contractor: ❑Not approved <br /> Engineer: Remarks: <br /> Submittal Date: <br /> Notes 1: <br /> Notes 2: <br /> SS-01.18 page 1 SS-SUB-AF310-v0120220818 <br />