My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-23 2025-12-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
3003 W CASINO RD BLDG 40-23 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:24:27 AM
Creation date
11/18/2025 12:02:47 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AFCONO Seismic Braces <br /> mc. <br /> Engineered Solutions <br /> Longitudinal & Lateral Seismic Clamp <br /> Fig.AF775 <br /> FIG.AF775 FM Approved(Listing)per FM 1950-13(ASD) <br /> Service Pipe Longitudinal&Lateral Horizontal Load Rating at Brace Angle Lateral Load Rating <br /> Size Service Pipe <br /> 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° <br /> LW2 <br /> 21/2" Sch.10 940lbf 1140lbf 1370lbf 1530lbf 1730lbf 2460lbf 3010lbf 3360lbf <br /> (DN65) Sch.40 (4.18 kN) (5.07 kN) (6.09 kN) (6.81 kN) (7.70 kN) (10.94 kN) (13.39 kN) (14.95 kN) <br /> Metric Pipe <br /> LW2 <br /> 3" Sch.10 <br /> (DN80) Sch.40 <br /> Metric Pipe <br /> LW <br /> 4" Sch.10 780lbf 920lbf 1190lbf 1080lbf 11401bf 1610lbf 1970lbf 2200lbf <br /> (DN100) Sch.40 (3.47 kN) (4.09 kN) (5.29 kN) (4.80 kN) (5.07 kN) (7.16 kN) (8.76 kN) (9.79 kN) <br /> Metric Pipe <br /> LW <br /> 5" Sch.10 <br /> (DN125) Sch.40 <br /> Metric Pipe <br /> LW2 <br /> 6° Sch.10 1000lbf 1260lbf 1280lbf 1410lbf 1360lbf 1920lbf 2350lbf 2620lbf <br /> (DN150) Sch.40 (4.45 kN) (5.60 kN) (5.69 kN) (6.27 kN) (6.05 kN) (8.54 kN) (10.45 kN) (11.65 kN) <br /> Metric Pipe <br /> 8" Sch.10 830lbf 1140lbf 1330lbf 1470lbf 1380lbf 1960lbf 2400lbf 2680lbf <br /> DN200 Sch.40 (3.69 kN) (5.07 kN) (5.92 kN) (6.54 kN) (6.14 kN) (8.72 kN) (10.68 kN) (11.92 kN) <br /> ( ) Metric Pipe <br /> 1) Brace Angles are determined from Vertical. <br /> 2) LW Refers to FM Approved Lightwall pipe,commonly referred to as Sch.7 and Flow Pipe.See FM Approval Guide for approved Lightwall pipe. <br /> 3) Sch.10&0.188"Wall Load Ratings may be used for any thicker wall pipe of the same diameter. <br /> 4) See table below for FM listed specialty pipes&FM Listed metric service pipes. <br /> 5) Load Ratings reflect 1"(DN25)-11/a"(DN32) brace members.See table below for listed brace members. <br /> 6) Minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3.To convert the load ratings above to a safety factor of <br /> 2.2 per NFPA 13-2019 Section A.18.5.2.3,multiply load ratings by a factor of 0.68. <br /> 7) To convert to LRFD Load Ratings,ASD Load Ratings may be multiplied by a factor of 1.5. <br /> 6 (X 4!r <br /> Longitudinal Application Lateral Application Riser Application <br /> ®©o <br /> asc-es.com <br /> Building connections that last" <br /> SS-06.21 page 3 SS-SUB-AF775-v0320220408 <br />
The URL can be used to link to this page
Your browser does not support the video tag.