Page 4 of 6 <br /> MICROFAST@ QUICK <br /> RESPONSE HORIZONTAL <br /> SIDEWALL SPRINKLER <br /> VK305 (K5.6) <br /> :G:: <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com <br /> Approval Chart 1 (UL) Temperature KEY <br /> Finish <br /> Microfast®Quick Response Horizontal Sidewall Sprinkler VK305 A1XF Escutcheon(if applicable) <br /> For Light or Ordinary Hazard Occupancies <br /> Maximum 175 PSI(12 Bar)WWP <br /> Deflector must be located 4"to 12"(102 mm to 305 mm)below the ceiling. <br /> Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals3 <br /> Base Part SIN (Refer also to UL Design Criteria.) <br /> Number' NPT BSPT U.S. metric' Inches mm cULus° China Approval <br /> 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1W, B1X,C2W, D2Z -- <br /> 19782' VK305 1/2" -- 5.6 80.6 1 2-11/16 68 1 E3 E3 <br /> NOTICEOffice) <br /> 12121 1 VK305 1/2" 1 15 mm 1 5.6 80.6 1 2-11/16 1 68 A1W, B1X,C2W, D2Z -- <br /> Approved Temperature Ratings <br /> A- 135 OF(57-C), 155 OF(68°C), 175 OF(79-C), Approved Escutcheons <br /> 200 OF(93°C),and 286 OF(141 °C) Approved Finishes W-Installed with standard surface-mounted escutcheons <br /> B-135 OF(57-C), 155 OF(68-C), 175 OF(79-C), 1 - Brass, Chrome, White Poly-ester5,6 X - Installed with standard surface-mounted escutch- <br /> and 200 OF(93°C) and Black Polyesters,' eons or recessed with the Viking Micromatic®Model <br /> C-155 OF(68-C), 175 OF(79-C),200 OF(93°C), 2-ENT' E-1, E-2,or G-1 Recessed Escutcheon <br /> and 286 OF(141 °C) Z - Installed with standard surface-mounted escutch- <br /> D - 155 OF (68 °C), 175 OF (79 °C), and 200 OF 3-Chrome eons or recessed with the Viking Micromatic Model <br /> (93 OC) E-1 <br /> E-155 OF(68-C) <br /> Footnotes <br /> Base part number shown. For complete part number, refer to Viking's current price schedule. <br /> 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. <br /> 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. <br /> °Listed by Underwriters Laboratories Inc.for use in the U.S. and Canada. <br /> ScULus Listed as corrosion-resistant. <br /> 'Other colors are available on request with the same Listings and Approvals as the standard colors. <br /> 'Approved according to China GB Standard. <br /> DESIGN CRITERIA- UL <br /> (Also refer to Approval Chart 1.) <br /> cULus Listing Reauirements: <br /> Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of <br /> NFPA 13 for sidewall standard spray sprinklers. <br /> • Designed for use in Light and Ordinary Hazard occupancies. <br /> • Locate with the deflector 4"to 12"(102 mm to 305 mm)below the ceiling. <br /> • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. <br /> • Minimum spacing allowed is 6 ft. (1.8 m). <br /> • Align the top of the deflector parallel with the ceiling. <br /> • Locate no less than 4"(102 mm)from end walls. <br /> • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured <br /> perpendicular to the wall. <br /> • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. <br /> IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers.Also refer to Bulletin Form No. <br /> F_080614 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with <br /> the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organiza- <br /> tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. <br /> Form No. F_060914 19.11.21 Rev 19.2 <br />