PV MODULE RATING @ STC MICROINVERTERS SPECIFICATION Rooftop conductor ampacities designed in compliance with 120% RULE art.690.8,Tables 310.15(B)(1),310.15(C)(1),310.15(B)(2), J <br /> C" <br /> MICROINVERTER MAKE AP SYSTEMS <br /> MANUFACTURER ZNSHINESOLAR ZXM7 SH108 410M 310.16,Chapter 9 Table 4,5,&9.Location specific BUS BAR RATING X 120% MAIN BREAKER RATING <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS M MAXIMUM <br /> AC OUTPUT <br /> MODEL N0. DS W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD infinity olar <br /> MAXIMUM AC OUTPUT 768 W <br /> MAX.POWER-POINT VOLTAGE(VMP) 31.30 VOLTS MAX INPUT VOLTAGE 60 V INFINITY HOME SOLUTIONS <br /> RECORD LOW TEMP -5°C (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS MAX AC CURRENT 3.20 A VANCOUVER WA 98661 <br /> MAX OUTPUT VOLTAGE 240 V AMBIENT TEMP(HIGH TEMP 2%) 26°C PHONE:1-800-818-0598 <br /> SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS THIS PANEL IS FED BY MULTIPLE SOURCES INFINITY SOLAR.COM <br /> NOM.MAX.POWER AT STC(PMAX) 410 WATT MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" (UTILITY AND SOLAR) <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH ROOFTOPTEMP 48°C REVISIONS <br /> MAX.SYSTEM VOLTAGE 1500V RAPID SHUTDOWN) NEEDS TO BE LOCATED CONDUCTOR TEMPERATURE RATE 90°C AC OUTPUT CURRENT 19A Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C WITHIN 3FT OF AC DISCONNECT. NOMINAL AC VOLTAGE 240V Initial Design 3/27/24 00 <br /> MODULE: (11)ZNSHINESOLAR ZXM7-SH108-410M VISIBLE, LOCKABLE, LABELED DISCONNECT <br /> INVERTER: (06)AP SYSTEMS DS3-L WITHIN 10' OF UTILITY METER POINT OF INTERCONNECT, LOAD SIDE <br /> EXISTING 240V/200A BUS BAR RATING, Signature with Seal <br /> NOTE : MAIN SERVICE PANEL,SINGLE PHASE, <br /> ATTIC RUN -YES WITH A 200A MAIN BREAKER <br /> SHUTDOWN - NO UTILITY COMPANY-SNOHOMISH <br /> COUNTY PUD <br /> UTILITY METER#55 279 890 <br /> EXISTING <br /> BI-DIRECTIONAL <br /> (11)ZNSHINESOLAR ZXM7-SH108-410M UTILITY METER, Project Name& <br /> (06)AP SYSTEMS DS3-L INVERTERS (N) 125A COMBINER PANEL, (N)BLADE TYPE M 1-PHASE,3W, Address <br /> BRANCH 1 240V,3W,1-PHASE NON-FUSIBLE AC DISCONNECT 06 MODULES WITH 03 MICRO INVERTERS 120V/240V <br /> NEMA 3R 30A-2P 120/240VAC <br /> IN __J __J ___ I 1 11 (VISIBLE, LOCKABLE, LABELED) LU <br /> U <br /> 200A E°{ z w <br /> (E)LOADS N <br /> L y F— rn Q <br /> Ji L _ Ji (N)JUNCTION BOX < z z <br /> 600 V, NEMA 4 15A (N)PV BREAKER t j w <br /> N N UL LISTED 30A/2P (D v w o < <br /> ---------- ---------- --------I o L1 �� c7 of a- Lu <br /> BRANCH 2-05 MODULES WITH 03 MICRO INVERTERS I L1 L1 15A L2 mLU <br /> Z c�I LU <br /> L2 L2 LU <br /> I ~ <br /> L1 L1 ~ <br /> G Y <br /> L2 L2 I G <br /> I <br /> -- ---- — G L G <br /> I I I I I <br /> i Sheet Name <br /> _______ __________ EXISTING GROUNDING DIAGRAM <br /> _______J <br /> 1 2 3 1 3 ELECTRODE SYSTEM DIAGRAM <br /> Sheet Size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPEWMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 1„ 17„ <br /> TAG# DEVICES RATING MULT CURR X 125% OCP GND DE-RATE: FILL: AMP: AMPACITY CURRENT FT. MAX DROP( ) <br /> Sheet Number <br /> O 03 x 3.20 x N/A = 9.60A 12.00A #10\THWN\40A @90°C 15A 2 TRUNK <br /> #6 AWG 20 0.28 <br /> AIR BLE 1.00 x 1.00 x 40A 40.00A E 1 .1 <br /> 9.60A <br /> O 03 x 3.20 x N/A = 9.60A 12.00A #10\THWN\40A @90°C 15A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 9.60A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O06 x 3.20 x N/A = 19.20A 24.00A #10\THWN \ 35A @75°C 30A 2 3/4" EMT 1.00 x 1.00 x 35A 35.00A 19.20A #8 AWG 10 0.17 <br />