Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING A STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-L 310.16, Chapter 9 Table 4, 5, &9. Locations specific BUS BAR RATING X 120%) - MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p infinity <br /> solar <br /> AC OUTPUT 768 W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA98661 <br /> PHONE:1-800-818-0598 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP 5°CINFINITY SOLAR.COM <br /> AMBIENT TEMP HIGH TEMP 2°/ ° THIS PANEL IS FED BY MULTIPLE SOURCES <br /> MODULE: (13) ZNSHINESOLAR ZXM7-SH108-410M NOM.MAX.POWER AT STC(PMAX) 410 WATT ( �) 26 C UTILITY AND SOLAR)) REVISIONS <br /> INVERTER: (07)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8" Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C AC OUTPUT CURRENT 22A Initial Design 4/11/24 00 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CONDUCTOR TEMPERATURE RATE 901C NOMINAL AC VOLTAGE 240V <br /> WITHIN 10' OF UTILITY METER NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED POINT OF INTERCONNECT,SUPPLY BREAKER <br /> NOTE : WITHIN 3FT OF AC DISCONNECT. EXISTING 240V/200A BUS BAR RATING, Signature with Seal <br /> ATTIC RUN -YES SOLAR READY CENTERFED MAIN <br /> SHUTDOWN - NO SERVICE PANEL,SINGLE PHASE,WITH A <br /> 200A MAIN DISCONNECT <br /> UTILITY COMPANY-SNOHOMISH PUD <br /> (N) PV BREAKER UTILITY METER#71 427 830 <br /> 30Al2P <br /> -0 : C Project Name& <br /> (13) ZNSHINESOLAR ZXM7-SH108-410M Address <br /> (07) AP SYSTEMS DS3-L INVERTERS (N) 125A COMBINER PANEL, (N)BLADE TYPE (E)LOADS <br /> 240V,3W,1-PHASE NON-FUSIBLE AC DISCONNECT w <br /> BRANCH 1 -07 MODULES WITH 04 MICRO INVERTERS NEMA 3R 30A 2P 120/240VAC 0 <br /> LJJ <br /> (VISIBLE, LOCKABLE, LABELED) 200A o <br /> w <br /> T w Q o <br /> M N <br /> (E)LOADS J rn Q11 Ell] I I <br /> Q <br /> 0 LU 3: <br /> (N)JUNCTION BOX CO0- w � z J <br /> 600 V, NEMA 4 20A L v w O < <br /> UL LISTED (E)LOADS z O w t1 w <br /> ------- ---------- ---------- ------- <br /> BRANCH 2-06 MODULES WITH 03 MICRO INVERTERS 15A L1 } o w <br /> L1 L1 L2 <br /> w N <br /> L2 L2 U <br /> w <br /> L1 L1 TO <br /> G <br /> L2 L2 F------ -------- --- ---- ------ - INTERNAL 0 <br /> G _____— F PANEL <br /> G J L Sheet Name <br /> J J L J L J <br /> -1- 3-LINE <br /> ---------- ---------- --------J EXISTING GROUNDING DIAGRAM <br /> 1 2 3 3 ELECTRODE SYSTEM <br /> Sheet Size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. GND LENGTH VOLTAGE 1 1" X 17„ <br /> TAG# DEVICES RATING MULT CURR X 125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT FT. MAX DROP(/o) <br /> Sheet Number <br /> 04 x 3.20 x N/A = 12.80A 16.00A #10\THWN \40A @90°C 20A 2 TRUNK <br /> AIR CABLE <br /> 1.00 x 1.00 x 40A 40.00A <br /> 12.80A #6 AWG 20 0.28 E 1 .1 <br /> O 04 x 3.20 x N/A = 12.80A 16.00A #10\THWN \40A @90°C 20A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 12.80A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O07 x 3.20 x N/A = 22.40A 28.00A #10\THWN \ 35A @75°C 30A 2 3/4" EMT 1.00 x 1.00 x 35A 35.00A 22.40A #8 AWG 10 0.17 <br />