Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM LEGEND <br /> 0 SYSTEM SIZE: 5.33 kW DC BILL OF MATERIALS <br /> 5.3 kW AC NUMBER OF MODULES 13 ZNSHINESOLAR ZXM7-SH108-410M EXISTING EXTERIOR MAIN SERVICE PANEL&POINT 0 <br /> MODULE TYPE&AMOUNT: (13)ZNSHINESOLAR ZXM7-SH108-410M NUMBER OF INVERTER 07 AP SYSTEMS DS3-L �M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinity s❑I❑r <br /> METER#71 427 830. <br /> MODULE DIMENSIONS: (L/W/H)67.87"/44.64"/1.8" COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER INFINITY HOME SOLUTIONS <br /> INVERTER: (07)AP SYSTEMS DS3-L 816L125RP NEW VISIBLE,LOCKABLE,LABELED DISCONNECT 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 30A NON-FUSIBLE AC DISCONNECT,240V AC LOCATED WITHIN 10'FROM THE UTILITY METER VANCOUVER WA 98661 <br /> PHONE:1-800-818-0598 <br /> NUMBER OF ATTACHMENTS 40 GRASOL GS-10 RAIL ATTACHMENTS INFINITY SOLAR.COM <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT RAILS 7 GRASOL RACKING SYSTEM © NEW DEDICATED PV SYSTEM COMBINER PANEL. <br /> WITHIN 10' OF UTILITY METER RAIL SPLICE 4 SPLICE KIT REVISIONS <br /> MID CLAMPS 18 MID CLAMPS/UFO Description Date Rev <br /> 13 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES Initial Design 4111/24 00 <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH END CLAMPS 16 END CLAMPS/STOPPER SLEEVE WITH NEW(07)-AP SYSTEMS DS3-L INVERTERS. <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED GROUNDING LUG 8 GROUNDING LUG <br /> WITHIN 3FT OF AC DISCONNECT. =FIRE PATHWAY <br /> EXISTING EXTERIOR MAIN SERVICE PANEL <br /> Signature with Seal <br /> NOTE : &POINT OF INTERCONNECTION.TIED TO <br /> ATTIC RUN-YES EXTERIOR UTILITY METER#71 427 830 ❑ =ROOF OBSTRUCTIONS <br /> ATTIC FAN-NO NEW PV AC DISCONNECT GROUPED • =ATTACHMENT POINTS <br /> SHUTDOWN-NO WITH SERVICE EQUIPMENT(VISIBLE, <br /> LOCKABLE,LABELED) <br /> =RAFTER <br /> NEW AC COMBINER PANEL <br /> --- =RACKING SYSTEM <br /> Project Name& <br /> C AC M O Address <br /> — =ATTIC RUN <br /> LU <br /> r Y O C� =CONDUIT ATTIC RUN JUNCTION BOX z <br /> CU LU <br /> LUco LU <br /> H <br /> \ (1) LUQ O <br /> w � N <br /> Q LL ROOF SECTIONS J J rn Q Q <br /> iy o ; � ? z <br /> ROOF#01 <br /> W NEW PV ATTACHMENTS AT 2'8"O.C. MODULE-04 1 L L SLOPE-44' (If Y � z Q <br /> J U AZIMUTH-181° LU <br /> LU 0 <br /> J MATERIAL-COMPOSITE SHINGLE Z O 1 � LU <br /> �J,J O 18"FIRE SETBACK — i w <br /> 18"FIRE SETBACK <br /> w =O RAFTER SIZE&SPACING-2"X4"@ 32"O.C. <br /> 18" I S B CK 8' FR T C o w <br /> Y __ RooF#oz MODULE-09 LU c�I <br /> z SLOPE-44' CD <br /> O Y/ AZIMUTH-181° uJ <br /> O LL MATERIAL-COMPOSITE SHINGLE <br /> RAFTER SIZE&SPACING-2"X4"@ 32"O.C. <br /> ry <br /> w <br /> I I I ROOF#01 <br /> — M <br /> MODULE, ARRAY WEIGHT (LOAD <br /> CV Sheet Name <br /> I I I I I CALC'S) SITE PLAN <br /> I I I I I <br /> Number of Modules 13 <br /> Module Weight 45.19 LBS Sheet Size <br /> N Total Module(Array)Weight 587.47 LBS <br /> ANSI B <br /> oA'gVi'uun�aupinr�aw Number of Attachment point 40 <br /> ."101\ N",/ rr 17 <br /> rr <br /> r 12'4" 19'8" 1' 7'-6" 3r 1 rr <br /> Mounting System Weight 1.5 LBS X <br /> 4" <br /> leer Module) <br /> RooF#02 - "Ni= Mounting System Weight 60.00 LBS Sheet Number <br /> y Total System Weight PV 1 .1 <br /> s (Module Weight+MounungsystemWeight) 647.47 LBS <br /> Weight at Each Attachment Point 14.69 LBS <br /> (Array Weight/Number of Attachment Point) <br /> Module Area(67.87"x44.64") 21.04 SgFt <br /> Total Array Area 273.52 SgFt <br /> CIRCUIT(S) Distributed Load 222 Per <br /> (Total System Weight/Total Array Area) Sq Ft <br /> CIRCUIT#1 —07 MODULES WITH 04 MICROINVERTERS <br /> Total Roof Area 1081 SgFt <br /> 1 SITE PLAN Total Percentage or Roof Covered 25.30% <br /> PV1.1 SCALE:3/16 V-0' CIRCUIT#2—06 MODULES WITH 03 MICROINVERTERS TotalAmayArea/TotalRoofAma/=,og <br />