Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM LEGEND <br /> SYSTEM SIZE: 4.100 kW DC BILL OF MATERIALS • <br /> NUMBER OF MODULES 10 ZNSHINESOLAR ZXM7SH108410M NEW INTERIOR MAIN SERVICE PANEL&POINT OF <br /> - - J <br /> 3.200 kW AC � INTERCONNECTION.TIED TO EXTERIOR UTILITY <br /> MODULE TYPE&AMOUNT: (10)ZNSHINESOLAR ZXM7-SH1 08-410M NUMBER OF INVERTER 05 AP SYSTEMS DS3-S METER#48 722 777. lnflnity olar <br /> MODULE DIMENSIONS: (LM/H)67.87"/44.64"/1.8" COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS <br /> INVERTER: (05)AP SYSTEMS DS3-S 816L125RP AC' LOCATED WITHIN 10'FROM THE UTILITY METER 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 30A NON-FUSIBLE AC DISCONNECT,240V VANCOUVER WA 98661 <br /> PHONE:1-800-818-0598 <br /> NUMBER OF ATTACHMENTS 21 CHIKO AL ROOF HOOK#167 © NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITY SOLAR.COM <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CK-FTS-167RT2 <br /> WITHIN 10'OF UTILITY METER RAILS 6 GRASOL RACKING SYSTEM REVISIONS <br /> RAIL SPLICE 4 SPLICE KIT 10 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES Description Date Rev <br /> NOTE : _ MID CLAMPS 18 MID CLAMPS/UFO WITH NEW(05)-AP SYSTEMS DS3-S INVERTERS. Initial Design 7/16/24 00 <br /> ATTIC RUN -YES <br /> ATTIC FAN NO — _ 'o END CLAMPS 4 END CLAMPS/STOPPER SLEEVE Revision 11/5/24 01 <br /> SHUTDOWN -YES 3g S A K ___-- GROUNDING LUG 2 GROUNDING LUG <br /> =FIRE PATHWAY <br /> _ MODULE, ARRAY WEIGHT(LOAD ❑O =ROOF OBSTRUCTIONS Signature with Seal <br /> CALC'S) <br /> Number of Modules 10 • =ATTACHMENT POINTS <br /> --_---- Module Weight 45.19 LBS <br /> =RAFTER <br /> _ Total Module(Array)Weight 451.90 LBS <br /> ❑ --——— Number of Attachment point 21 -—- =RACKING SYSTEM <br /> -- Mounting System Weight 15 LBS <br /> (Per Module) . — — =ATTIC RUN Project Name& <br /> ------ U1J Mounting System Weight 31.50 LBS Address <br /> _——— w Total System Weight =CONDUIT ATTIC RUN JUNCTION BOX <br /> ——— cn 483.40 LBS <br /> ———— : (Module Weight+Mounting System Weight) <br /> O <br /> _____ W oz Cn Weight at Each Attachment Point 21.52 LBS <br /> r U (Amoy Weight/Number of Attachment Point) <br /> -------- _ 0 Module Area(67.87"x44.64") 21.04 SgFt V <br /> 0 Total Array Area 210.40 SgFt w M <br /> aoor- 0 <br /> m - T Distributed Load Per t� w � <br /> M ____----- co (Total System Weight/Total Any Area) 230 SgFt ROOF SECTIONS w "' M z Q <br /> rn m Q z <br /> ______ Total Roof Area 1421 SgFt RooF#ol MODULE-10 U) w <br /> D D Total Percentage or Roof Covered 14.81% SLOPE-18° � 0 Q <br /> n ___————— TotalArrayArea/Total RoofArea)•loo AZIMUTH-185° ( ti L U = <br /> Z Ao MATERIAL-COMPOSITE SHINGLE cfl w a- Lu <br /> U) ———— o TRUSS SIZE&SPACING-2"X4"@ 24"O.C. w <br /> 0 <br /> C� <br /> Sheet Name <br /> L___---� SITE PLAN <br /> PTBA K <br /> Sheet Size <br /> 0 AC C ANSI B <br /> 11" X 17" <br /> NEW AC COMBINER PANEL N Sheet Number <br /> 1�o\x�NnnpmpmiuuP°Na/wig <br /> NEW PV AC DISCONNECT GROUPED �'%/ PV 1 .1 <br /> WITH SERVICE EQUIPMENT(VISIBLE, <br /> LOCKABLE,LABELED) NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> NEW INTERIOR MAIN SERVICE PANEL&POINT OF INTERCONNECTION.TIED TO RAPID SHUTDOWN) NEEDS TO BE LOCATED <br /> EXTERIOR UTILITY METER#48 722 777 WITHIN 3FT OF AC DISCONNECT. <br /> 1 SITE PLAN CIRCUIT(S) <br /> PV,., SCALE:1/8"=1'-0" CIRCUIT#1 - 10 MODULES WITH 05 MICROINVERTERS <br />