PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM LEGEND <br /> BILL OF MATERIALS <br /> SYSTEM SIZE: 5.330 kW DC NUMBER OF MODULES 13 ZNSHINESOLAR ZXM7-SH108-410M EXISTING INTERIOR MAIN SERVICE PANEL&POINT 0 <br /> 4.480 kW AC NUMBER OF INVERTER 07 AP SYSTEMS DS3-S �M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY <br /> MODULE TYPE&AMOUNT: (13)ZNSHINESOLAR ZXM7-SH108-410M METER#266063. infllllty`_,olar <br /> MODULE DIMENSIONS: (L/W/H)67.87"/44.64"/1.8" COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER <br /> INVERTER: 07 AP SYSTEMS DS3-S 816L125RP NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS <br /> ( ) AC LOCATED WITHIN 10'FROM THE UTILITY METER 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 30A NON-FUSIBLE AC DISCONNECT,240V VANCOUVER WA 98661 <br /> CHIKO AL ROOF HOOK#167 PHONE:1-800-818-0598 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT NUMBER OF ATTACHMENTS 35 CK-FTS-167RT2 © NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITY SOLAR.COM <br /> WITHIN 10' OF UTILITY METER RAILS 8 GRASOL RACKING SYSTEM REVISIONS <br /> RAIL SPLICE 4 SPLICE KIT 13 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES Description Date Rev <br /> MID CLAMPS 18 MID CLAMPS/UFO WITH NEW(07)-AP SYSTEMS DS3-S INVERTERS. <br /> Initial Design 8/28124 00 <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH END CLAMPS 16 END CLAMPS/STOPPER SLEEVE <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED ❑WITHIN 3FT OF AC DISCONNECT. GROUNDING LUG 8 GROUNDING LUG � =FIRE PATHWAY <br /> NOTE : <br /> MODULE, ARRAY WEIGHT (LOAD ❑❑ =ROOF OBSTRUCTIONS Signature with Seal <br /> CALC'S) <br /> ATTIC RUN-YES El Number <br /> =ATTACHMENT POINTS <br /> ATTIC FAN-NO Number of Modules 13 <br /> Module Weight 45.19 LBS <br /> SHUTDOWN-NO =RAFTER <br /> r7 Total Module(Array)Weight 587.47 LBS <br /> Number of Attachment point 35 =RACKING SYSTEM <br /> ❑ ❑ Mounting System Weight 1.5 LBS <br /> 0 (Per Module) —— =ATTIC RUN <br /> Mounting System Weight 52.50 LBS Project Name& <br /> 0 <br /> ❑ Total System Weight Address <br /> (Modula weight+Mounting Systa Weight) 639.97 LBS )C� =CONDUIT ATTIC RUN JUNCTION BOX <br /> ❑ Weight at Each Attachment Point <br /> (Array Welght1NumherofAttaehmentPoint) <br /> 16.78 LBS <br /> Module Area(67.87"x44.64") 21.04 SgFt w <br /> U <br /> Total Array Area 273.52 SgFt Z <br /> W co <br /> Distributed Load 2 34 Per o w o <br /> ❑ (Totaisystarn Might/Total Array A-) SgFt w U) 0 Q <br /> co <br /> Total Roof Area 1637 S Ft U) Q z c <br /> 2 q ROOF SECTIONS �' _ <br /> 3'-1" 11'4' - 22'-9" g Total Percentage or Roof Covered o LU <br /> Total Array Area/Total RoofArea)'100 16.71/o ROOF#01 MODULE-13 > ti H O Q <br /> 1 SLOPE-23' t j ILLI <br /> = w <br /> AZIMUTH-180' z c� j a <br /> MATERIAL-COMPOSITE SHINGLE Q W <br /> RAFTER SIZE&SPACING-2"X6"@ 24"O.C. <br /> ROOF#01 m <br /> LU III <br /> ( 1 Sheet Name <br /> SITE PLAN <br /> NEW PV ATTACHMENTS <br /> AT 4'-0"O.C. <br /> I I Sheet Size <br /> ANSI B <br /> EXISTING INTERIOR MAIN SERVICE PANEL 11" X 17" <br /> &POINT OF INTERCONNECTION.TIED TO <br /> EXTERIOR UTILITY METER#266063 N Sheet Number <br /> NEW PV AC DISCONNECT GROUPED ,0 PV <br /> a�ra������ PV 1 <br /> WITH SERVICE EQUIPMENT(VISIBLE, FRONT OF HOUSE <br /> LOCKABLE,LABELED) 2115 74TH ST SE <br /> NEW AC COMBINER PANEL <br /> CIRCUIT(S) <br /> CIRCUIT#1 -07 MODULES WITH 04 MICROINVERTERS <br /> 1 SITE PLAN CIRCUIT#2-06 MODULES WITH 03 MICROINVERTERS <br /> PV 1.1 SCALE:1/8"=V-0" <br />