SITE NOTES GROUNDING NOTES: 13 <br /> 1 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE. AND infinity <br /> REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH <br /> 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE HnNITY HOME SOLUTIONS <br /> UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES, 2 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM 6405E MILL PLAIN <br /> 3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL. NEC TABLE 250.122. PHONE 1-800-vA-0598 <br /> PHONE,1-800-818-0558 <br /> OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES INFINITYSOLARNOM <br /> 4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250 136, <br /> ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110 26, 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC REVISIONS <br /> 5 ROOF COVERINGS SHALL BE DESIGNED. INSTALLED, AND MAINTAINED IN 690.45 AND MICRO INVERTER MANUFACTURERS' INSTRUCTIONS "°"ooptio° wt° <br /> ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN Initial Design W4+24 Do <br /> INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ, IF WEEBS ARE <br /> BUILDING OR STRUCTURE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED <br /> GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION <br /> EQUIPMENT LOCATIONS: <br /> REQUIREMENTS Signature with Seal <br /> 1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110 26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT <br /> 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO <br /> OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES ANOTHER MODULE <br /> 310.15(B)(1)AND 310.15(13)(2). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED <br /> 3, JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250 1191 <br /> ACCORDING TO NEC 690 34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250 50 <br /> 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250,106 IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A <br /> WITHIN SIGHT OF THE AC SERVICING DISCONNECT, 2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690,47 Project Name& <br /> INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC <br /> AND AHJ. Address <br /> APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO <br /> 5 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS w <br /> USAGE WHEN APPROPRIATE. z <br /> DISCONNECTION AND OVER-CURRENT PROTECTION NOTES. w <br /> STRUCTURAL NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS 0 00 <br /> o <br /> OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE w w " <br /> 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO IY rn <br /> D Q <br /> CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED TERMINALS MARKED''LINE SIDE"(TYPICALLY THE UPPER TERMINALS). 0 F- ¢ Z z <br /> SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE 2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE J = w J <br /> BEYOND EITHER EDGE OF THE ARRAY SUBARRAY, ACCORDING TO RAI LOCKABLE.AND BE A VISIBLE-BREAK SWITCH z Q <br /> 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID rn w o <br /> MANUFACTURER'S INSTRUCTIONS. M or Lu <br /> 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY N w a <br /> ROOF-PENETRATING TYPE. IT SHALL BE FLASHED & SEALED PER LOCAL RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D) Q w <br /> REQUIREMENTS. 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690 8, 690.9, AND = <br /> 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED Wi 240. U <br /> APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 5. MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED <br /> 4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE FUSES IN ACCORDANCE WITH NEC 110.3(B) <br /> SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION <br /> POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED ACCORDING TO NEC 690,11 AND UL1699B. Sheet Name <br /> AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: <br /> 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705 121 NOTES <br /> 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT <br /> EXCEED 120%OF BUS BAR RATING[NEC 705.12(B)(3)(2)]. Sheet See <br /> WIRING&CONDUIT NOTES: 3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT <br /> 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR ANSI B <br /> CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUS BAR. PV 11" X 1T <br /> REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS <br /> 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8. NEC 690,7, FROM THE UTILITY SOURCE OCPD[NEC 705,12(B)(3)(1)]. Sheet Number <br /> 3. VOLTAGE DROP LIMITED TO 1.5%. 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL <br /> 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF E 1 .3 <br /> SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY Wi SUITABLE BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED <br /> WIRING CLIPS ACCORDING TO NEC 705.12(13)(3)(3). <br /> 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK 5 FEEDER TAP INTERCONNECTION(LOADSIDE)ACCORDING TO NEC 705.12(13)(1) <br /> PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- 6 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705 11 WITH SERVICE <br /> BLUE, YELLOW, ORANGE-, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230 42 2 7.8BACKFEEDING <br /> IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL <br /> BE MARKED ORANGE[NEC 110.151. FASTENING[NEC 705.12(E)) <br />