610 COLBY AVE 2025-12-01
>
Address Records
>
COLBY AVE
>
610
>
610 COLBY AVE 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2025 11:54:24 AM
Creation date
11/20/2025 10:37:37 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
610
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: v SYSTEM LEGEND <br /> SYSTEM SIZE: 00 kW DC <br /> 6,400 kW AC EXISTING INTERIOR MAIN SERVICE PANEL&POINI <br /> 6.4 MODULE TYPE&AMOUNT: (20)ZNSHINESOLAR ZXM7-SH108-410M ❑ OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinity <br /> MODULE DIMENSIONS: (UNIH)67.87"I44.64"118" METER#1 00141180. <br /> ITY <br /> INVERTER: (10)AP SYSTEMS DS3•S AC NEW VISIBLE,LOCKABLE,LABELED DISCONNECT IIJI 1164054E MILL PLAINONS <br /> A-IJ: CITY OF EVERETT LOCATED WITHIN 10'FROM THE UTILITY METER VANCOUVERWA98661 <br /> PHONE:1-800-818-0598 <br /> NOTE <br /> ATTIC RUN-NO ❑ NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITYBOLAR.COM <br /> ATTIC FAN- NO REVISIONS <br /> 20 NEW ZNSHINESOLAR ZXW-SH108A10M MODULES Description Date P. <br /> SHUTDOWN-NO WITH NEW(10)-AP SYSTEMS DS3-S INVERTERS. Initial Design 9024 00 <br /> VISIBLE, LOCKABLE, LABELED ❑ <br /> DISCONNECT WITHIN 10' OF UTILITY METER =FIRE PATHWAY <br /> ❑O =ROOF OBSTRUCTIONS Signature with Seal <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED o ❑ • =ATTACHMENT POINTS <br /> WITHIN 3FT OF AC DISCONNECT. ❑ =RAFTER <br /> --- W_ O LU RACKING SYSTEM <br /> THE STRUCTURE IS UNINHABITED cC/) Q <br /> o AND IS EXEMPT FROM FIRE ❑ p � — =EXTERIOR RUN Project Name& <br /> ACCESS PATHWAY REQUIREMENTS m cn Address <br /> LL <br /> O O J <br /> z O — — CONDUIT ROOF TOP JUNCTION BOX <br /> I— <br /> N ------------- LJ U ❑ � U Lu <br /> O U <br /> ---- — GO -- =TRENCH LLl <br /> z Cfl o <br /> LU------ = ci W > rn Q <br /> Q <br /> ---- ROOF SECTIONS = Q a z <br /> z <br /> V Q -1 w J <br /> ¢ O ROOFA01 MODULE O O HZ <br /> - Q <br /> -- -- w SLOPE-C8° UJ o_ w <br /> Z I �� O MATERIAL ROLLED COMP O cfl > <br /> —————— — j TRUSS SIZE&SPACING-2"X4"@ 16"QC, = 111 <br /> ------- — I U_ <br /> I <br /> NEW PV AC DISCONNECT J Z <br /> GROUPED WITH SERMCE <br /> EQUIPMENT(VISIBLE, <br /> LOCKABLE,LABELED) <br /> Sheet Name <br /> _ — ------- <br /> N <br /> i EXISTING INTERIOR MAIN SERVICE PANEL MODULE, ARRAY WEIGHT (LOAD <br /> C AC — - ---J &POINT OF INTERCONNECTION.TIED TO CALCfS) SITE PLAN <br /> EXTERIOR UTILITY METER#100141180 Number of Modules 20 <br /> N lodule Weight 45,19 LBS Sheet Size <br /> NEWAC COMBINER PANEL 1-114"PVC PIPE Total Module(Array)Weight 903.80 LBS ANSI B <br /> NEW PV AC DISCONNECT BILL OF MATERIALS Number of Attachment point 50 11" X 17" <br /> Mounting System Weight <br /> NUMBER OF MODULES 20 ZNSHINESOLARZXM7-SH108-410M +•r,rdfeJ 1,5 LBS Sheet Number <br /> 30-0"TRENCH TO BE 24"DEEP IWTH 18 NUMBER OF INVERTER 10 AP SYSTEMS DS3-S Mounting System Weight 88.50 LBS <br /> MINIMUM FILL ON TOP OF CONDUIT. Total System Weigh <br /> CAUTION TAPE PLACED 1'ABOVE CONDUIT EATON BR STYLE 1 NCH LOAD CENTER y g 992.30 LBS PV 1 .1 <br /> COMBINER NER PANEL 1 prodd�"i"a r+u„ e,"sysr-"fgn <br /> IF JURISDICTION REQUIRES), 816L125RP <br /> ( ) Weight at EachAttachmert Point 15.32 LBS <br /> AC DISCONNECT 2 60A NON-FUSIBLE AC DISCONNECT,240V glen/"ght Munb—fAbd,.-0P.uf) <br /> NUMBER OF ATTACHMENTS 59 RT-(N)-DECK MOUNT MINI BASE Module Area(67,87"x44.64") 21.04 SgF1 <br /> CIRCUIT(S) RAILS 11 GRASOL RACKING SYSTEM Total Array Area 420,79 Per <br /> RAIL SPLICE 8 SPLICE KIT Distributed Load 2.36 <br /> ®CIRCUIT#1 - 10 MODULES WITH 05 MICROINVERTERS MID CLAMPS 32 MID CLAMPS)UFO ( tdSpb.B "iCAW44A-VA—) SgFt <br /> SITE PLAN END CLAMPS 16 END CLAMPS I STOPPER SLEEVE Total Roof Area 701 SgFt <br /> ®CIRCUIT#2- 10 MODULES WITH 05 MICROINVERTERS Total Percentage or Roof Covered 60.03% <br /> pvI SCALE: 1r8"=V-0" GROUNDING LUG 8 GROUNDING LUG rarArr°.,Ar°a+rfdRbdA—)'?M <br />
The URL can be used to link to this page
Your browser does not support the video tag.