Laserfiche WebLink
PV Electrical Calculations &ffl. 'I�� <br /> Watts Output #of Total AC Comb. EGC A&RSO LAR <br /> Inverter Specs AC Voltaire OCPD Interconnection Calcs Site Conditions <br /> Inverters out.(A) OCPD AC 9700 Martin Luther King Jr WayS, <br /> y) 7600 32.00 240 1 40 Main Breaker 200 ASHRAESite: Seattle Seattle,WA 98118(206)707-9937 <br /> y) 5000 20.83 240 1 30 S2.8 70 #8 Bus Bar 200 Low Temp(°F) 19 <br /> ****N/A**** 0 0.00 0 0 0 1 Max PV OCD Allowed 40 High 2%Temp(°F) 84 <br /> Module Specs Watts IMP Vmp Voc Isc Temp. Coef V(oc) EGC <br /> (W) 1p_C1 PV OCPD Device Used 70 High 0.4%Temp(°F) 91 <br /> Silfab ELITE SIL-420 BG 420 10.91 38.51 46.36 11.40 -0.279 #10 Tap or Breaker? Tap <br /> THIS ING CONSTITUTES THE <br /> Temp.Adjusted 34.3 50.5 CON ID NTIAL IJNFORMATION OF A&R SOLAR <br /> MLPE or RSD7. Tesla MCI-2 (3) modules (max)per MCI FMax Array Power(STC): 15.12kW DC Max Continuous AC Power: 12.6kW A AND ITS RECEPTOR.POSSESSION D T <br /> CONFER ANY RIGHT IN OR LICENSE TOO U USESE IT <br /> OR THE INFORMATION DISCLOSED HEREIN <br /> NOR ANY RIGHT TO REPRODUCE THIS <br /> DRAWING OR ANY PART HEREIN WITHOUT <br /> Equipment 1-Tesla PVI7.6kw(15380000-xx-y) 1-Tesla PVI5.0kw(15380000-xx-y) ****N/A**** THE WRITTNCONSNTOFA&RSOLAR. <br /> Mppt Input 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 1 5 1 6 <br /> Module Silfab ELITE SIL-420 BG Silfab ELITE SIL-420 BG ****SELECT**** <br /> # Modules per String 7 7 7 0 0 0 9 6 0 0 0 0 0 0 0 0 0 0 <br /> #Strings 1 1 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 U <br /> #of Mods per group 7 7 7 0 0 0 9 6 0 0 0 0 0 0 0 0 0 0 Q <br /> #of Mods/inverter 21 15 0 ,^ ; Mo <br /> #of Inverters 1 1 0 o r, o Q N <br /> _Total#of Modules ra Un ra 00 36 ' <br /> -0 <br /> Q <br /> Q <br /> Array Specs (Adjusted for Temperature) E Q <br /> � <br /> I nverter 1-Tesla PV17.6kw(15380000-xx-y) 1-Tesla PVl 5.Okw(15380000-xx-y) ****N/A**** U <br /> Ln <br /> Mppt Input 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 E '-"% U44-J <br /> Amperage (Imp) 10.91 10.91 10.91 0.00 0.00 0.00 10.91 10.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 E 'zl- n <br /> Voltage (Vmp) 240.1 240.1 240.1 0.0 0.0 0.0 308.7 205.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 OL > <br /> Max Voltage(DC) 353.5 353.5 1 353.5 1 0.0 1 0.0 0.0 454.5 303.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 d (V (V Lu <br /> ,-� <br /> Max Amps (DC) 11.40 11.40 11.40 0.00 0.00 0.00 11.40 11.40 0.00 0.00 0.00 0.00 0.00 1 0.00 0.00 0.00 0.00 0.00 Ln <br /> ,--1 <br /> Distance Wire (QTY)Phase Neutral Neutral EGC Wire Type Conduit Min. 90°C Temp Fill Derated 75°C Current Operating Voltage Drop <br /> Ref. Conductor Description ft AL CU Gauge Conductors AW6 (QTy) (AWE) Type Conduit Rating Correct. Derate Ampacity Rating 1 5% Voltage <br /> A String to Jbox 50 CU #10 2 N/A N/A #6 PV Wire 600V AIR N/A 40 1 100% 40.00 35 17.8 240 0.56% <br /> B Jbox to I nverterl 35 CU #10 6 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 17.8 240 0.40% REVISIONS <br /> C Jbox to I nverter2 45 CU #10 4 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 17.8 309 0.40% Rev. #: Date: <br /> D Inverterl to Combiner 10 CU #8 2 #8 1 #10 THWN-2 EMT 0.75" 55 1 100% 55.00 50 40.0 240 0.21% <br /> E Inverter2 to Combiner 10 CU #10 2 #8 1 #10 THWN-2 EMT 0.75" 40 1 100% 40.00 35 26.0 240 0.22% <br /> F Combiner to Disconnect 10 CU #4 2 #8 1 #8 THWN-2 EMT 1" 95 1 100% 95.00 85 66.0 240 0.14% <br /> G Disco. to Interconnect 10 CU #4 2 #6 1 #6 THWN-2 PVC 1" 95 1 100% 95.00 85 66.0 240 0.14% Designed by: Tyler M. <br /> H Project Manager: <br /> Arthur Eith <br /> 1 (612) 298-1795 <br /> J Current Date:Dec 06, 2024 <br /> E2 Electrical <br /> DC Voltage Drop 1.36% AC Voltage Drop 0.70% Total Voltage Drop 2.05% E2El Calculations <br />