Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS MODULE, ARRAY WEIGHT (LOAD SYSTEM LEGEND <br /> SYSTEM SIZE: 5.330 kW DC NUMBER OF MODULES 13 ZNSHINESOLAR ZXM7-SH108-410M CALC'S) EXISTING INTERIOR MAIN SERVICE PANEL&POINT <br /> 4.480 kW AC NUMBER OF INVERTER 07 AP SYSTEMS DS3-S Number of Modules 13 �M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinity polar <br /> MODULE TYPE&AMOUNT: (13)ZNSHINESOLAR ZXM7-SH108-410M METER#338949. <br /> EATON BR STYLE 1-INCH LOAD CENTER Module Weight <br /> MODULE DIMENSIONS: (L/W/H)67.87"/44.64"/1.8" COMBINER PANEL 1 9 45.19 LBS <br /> 8161_125RP INFINITY HOME SOLUTIONS <br /> INVERTER: (07)AP SYSTEMS DS3-S Total Module(Array)Weight 587.47 LBS NEW VISIBLE,LOCKABLE,LABELED DISCONNECT 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 30A NON FUSIBLE AC DISCONNECT,240V Number of Attachment point 43 AC LOCATED WITHIN 10'FROM THE UTILITY METER VANCOUVER WA 98661 <br /> CHIKO AL ROOF HOOK#167 PHONE:1-800-818-0598 <br /> NOTE: CK-FTS-167RT2 1.5 LBS <br /> NUMBER OF ATTACHMENTS 43 Mounting System Weight INFINITY SOLAR.COM <br /> C NEW DEDICATED PV SYSTEM COMBINER PANEL. <br /> VISIBLE <br /> ATTIC RUN-YES LOCKABLE, LABELED RAILS 9 CHIKO 518 RAIL 4200MM (per module)Mounting System Weight 64.50 LBS REVISIONS <br /> ATTIC FAN-NO DISCONNECT WITHIN 10' OF RAIL SPLICE 4 SPLICE KIT Total System Weight Description Date Rev <br /> SHUTDOWN-NO UTILITY METER MID CLAMPS 14 MID CLAMPS/UFO (Module Weight+Mounting System Weight) 651.97 LBS 13 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES <br /> END CLAMPS 24 END CLAMPS/STOPPER SLEEVE Weight at Each Attachment Point WITH NEW(07)-AP SYSTEMS DS3-S INVERTERS. Initial Design 12/18/24 00 <br /> (Array Weight/Numhern(Attachment Point) 13.66 LBS <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH GROUNDING LUG 12 GROUNDING LUG Module Area(67.87"x44.64") 21.04 SgFt <br /> Total Array =FIRE PATHWAY <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED y Area 273.52 SgFt ® <br /> WITHIN 3FT OF AC DISCONNECT. Distributed Load Per Signature with Seal <br /> (Total System Weight Total Array Area) 2'38 Sq Ft �� =ROOF OBSTRUCTIONS <br /> Total Roof Area 975 SgFt =ATTACHMENT POINTS <br /> Total Percentage or Roof Covered 28.05% <br /> Total Array Area/Total Roo/Area) <br /> =RAFTER <br /> Y O <br /> --- =RACKING SYSTEM <br /> m <br /> H <br /> w — =ATTIC RUN Project Name& <br /> Address <br /> CO =CONDUIT ATTIC RUN JUNCTION BOX Lu <br /> U <br /> Z <br /> Lu <br /> 0 <br /> cn <br /> Lu <br /> � o <br /> ~ co U) rnQ <br /> ROOF SECTIONS w J Q z z <br /> _ r <br /> NEW PV ATTACHMENTS AT 4'-0"O.C. C/) RooF ao1 MODULE-13 z ¢ 1= z J <br /> w SLOPE-24° w O <br /> J AZIMUTH-182° LLI o Of Lu <br /> 18" IRE S B CK = 0- MATERIAL-COMPOSITE SHINGLE � u.l <br /> RAFTER SIZE&SPACING-2"X4"@ 24"O.C. I j w <br /> 18"FI ETBACK o U <br /> Q Y O <br /> I I I I U <br /> m <br /> I w � <br /> — LU Sheet Name <br /> LL <br /> SITE PLAN <br /> II I I q <br /> I Sheet Size <br /> M ANSI B <br /> OAC C 11" X17" <br /> 1'-4" 35'-7" 3'-1" 4r <br /> Sheet Number <br /> ROOF#01 NEW AC COMBINER PANEL N PV 1 .1 <br /> 1�„1winyixluy,y"�,ga <br /> EXISTING INTERIOR MAIN SERVICE PANEL ��� ���, <br /> NEW PV AC DISCONNECT GROUPED <br /> &POINT OF INTERCONNECTION.TIED TO WITH SERVICE EQUIPMENT(VISIBLE, \ <br /> EXTERIOR UTILITY METER#338949 LOCKABLE,LABELED) ir <br /> CIRCUIT(S) `"'amp, <br /> 1 SITE PLAN CIRCUIT#1 -07 MODULES WITH 04 MICROINVERTERS <br /> Pv,., SCALE:3/16"=1'-0" CIRCUIT#2-06 MODULES WITH 03 MICROINVERTERS <br />