My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2124 E GRAND AVE 2025-12-01
>
Address Records
>
E GRAND AVE
>
2124
>
2124 E GRAND AVE 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2025 7:54:11 AM
Creation date
11/20/2025 10:56:42 AM
Metadata
Fields
Template:
Address Document
Street Name
E GRAND AVE
Street Number
2124
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MICROINVERTERS SPECIFICATION PV MODULE RATING @ STC Rooftop conductor ampacities designed in compliance with 120% RULE 0 <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8,Tables 310.15(B)(1), 310.15(C)(1), 310.151 <br /> MICROINVERTER MODEL NO. DS3-S 310.16, Chapter 9 Table 4, 5, &9. Location specific BUS BAR RATING X 120%)- MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p _ infinity <br /> solar <br /> AC OUTPUT 640 W temperature obtained from ASHRAE 2017 data tables - MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER-POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 2.66 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA98661 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP -5°C PHONE:1-800-818-0598 <br /> THIS PANEL IS FED BY MULTIPLE SOURCES INFINITY SOLAR.COM <br /> NOM.MAX.POWER AT STC(PMAX) 410 WATT AMBIENT TEMP(HIGH TEMP 2%) 26°C (UTILITY AND SOLAR) <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT REVISIONS <br /> WITHIN 10' OF UTILITY METER MAX.SYSTEM VOLTAGE 1500v CONDUIT HEIGHT 7/8 AC OUTPUT CURRENT 27A Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C Initial Design 12/11/24 00 <br /> NOTE : CONDUCTOR TEMPERATURE RATE 90°C NOMINAL AC VOLTAGE 240V <br /> ATTIC RUN -YES MODULE: (20)ZNSHINESOLAR ZXM7-SH108-410M <br /> SHUTDOWN -NO INVERTER: (10)AP SYSTEMS DS3-S NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> Signature with Seal <br /> NOTE:-TANDEM BREAKERS TO BE USED TO RAPID SHUTDOWN) NEEDS TO BE LOCATED POINT OF INTERCONNECT, LOAD BREAKER <br /> MAKE ROOM FOR PV CIRCUIT BREAKER WITHIN 3FT OF AC DISCONNECT. EXISTING 240V/200A BUS BAR RATING, <br /> MAIN SERVICE PANEL,SINGLE PHASE, <br /> WITH A 200A MAIN BREAKER <br /> UTILITY COMPANY-P.U.D#1 <br /> SNOHOMISH COUNTY <br /> UTILITY METER#76 375 586 <br /> EXISTING Project Name& <br /> Address <br /> BI-DIRECTIONAL <br /> (20)ZNSHINESOLAR ZXM7-SH108-410M M UTILITY METER, <br /> (10)AP SYSTEMS DS3-S INVERTERS (N) 125A COMBINER PANEL, (N)BLADE TYPE 1-PHASE,3W, U <br /> NON-FUSIBLE AC DISCONNECT 120V/240V z <br /> BRANCH 1 10 MODULES WITH 05 MICRO INVERTERS 240V,3W,1-PHASE w <br /> NEMA 3R 60A-2P 120/240VAC o <br /> (VISIBLE, LOCKABLE, LABELED) w > o <br /> 200A E°{ � o rn ¢ Q <br /> U) Z Q z Z <br /> in . J Q Q � w <br /> (N)JUNCTION BOX (E)LOADS U z J <br /> I_ _ _J I_ _ -1 L _ _J I_ _ _J L _ 600 V, NEMA 4 o z w w <br /> N PV BREAKER Lu Ofw <br /> UL LISTED zoA ( ) � LU `� LU <br /> N w <br /> BRANCH 2-10 MODULES WITH 05 MICRO INVERTERS L1 40A/2P <br /> 20A <br /> DuL1 L2 <br /> L2 L2 <br /> I <br /> L1 L1 <br /> 41 G _ _ <br /> -- ----- — o G G Sheet Name <br /> 3-LINE <br /> -------------------------------------- ------- -J =1= DIAGRAM <br /> 1 2 3 3 EXISTING GROUNDING <br /> ELECTRODE SYSTEM sheet size <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. GND LENGTH VOLTAGE 11"X 17" <br /> TAG# DEVICES RATING MULT CURR X 125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT FT. MAX DROP( ) <br /> Sheet Number <br /> #10\THWN\40A @90°C 20A 2 TRUNK CABLE 1.00 x 1.00 x 40A 40.00A 13.30A E 1 .1 <br /> 05 x 2.66 x N/A = 13.30A 16.63A IN AIR #6 AWG 20 0.28 <br /> 1.34< <br /> 2 05 x 2.66 x N/A = 13.30A 16.63A #10\THWN\40A @90°C 20A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 13.30A #8 AWG 55 0.76 2 <br /> O10 x 2.66 x N/A = 26.60A 33.25A #8 \THWN \50A @75°C 40A 2 3/4" EMT 1.00 x 1.00 x 50A 50.00A 26.60A #8 AWG 10 0.15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.