Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: MODULE, ARRAY WEIGHT (LOAD BILL OF MATERIALS SYSTEM LEGEND <br /> SYSTEM SIZE: 8.200 kW DC CALC'S) NUMBER OF MODULES 20 ZNSHINESOLAR ZXM7-SH108-410M EXISTING INTERIOR MAIN SERVICE PANEL&POINT V <br /> 6.400 kW AC M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY <br /> MODULE TYPE&AMOUNT: (20)ZNSHINESOLAR ZXM7-SH108-410M Number of Modules 20 NUMBER OF INVERTER 10 AP SYSTEMS DS3 S Infllllty:_Oar <br /> Module Weight EATON BR STYLE 1-INCH LOAD CENTER METER#76 375 586. <br /> MODULE DIMENSIONS: (L/W/H)67.87"/44.64"/1.8" 9 45.19 LBS COMBINER PANEL 1 816L125RP INFINITY HOME SOLUTIONS <br /> INVERTER: (10)AP SYSTEMS DS3-S Total Module(Array)Weight 903.80 LBS NEW VISIBLE,LOCKABLE,LABELED DISCONNECT 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT Number of Attachment point 52 AC DISCONNECT 1 60A NON FUSIBLE AC DISCONNECT,240V AC LOCATED WITHIN 10'FROM THE UTILITY METER VANCOUVER WA 98661 <br /> Mounting System Weight 1.5 LBS NUMBER OF ATTACHMENTS 52 CK-FTHIKO -1 ROOF HOOK#167 PHONE:1 SOLAR.CO 8 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CHIKO5167RT2 ❑ INFINITY SOLAR.COM <br /> (Per Modu�eJ L' NEW DEDICATED PV SYSTEM COMBINER PANEL. <br /> Mounting System Weight 78.00 LBS RAILS 11 CHIKO 518 RAIL 4200MM REVISIONS <br /> WITHIN 10' OF UTILITY METER Total System Weight RAIL SPLICE 6 SPLICE KIT Description Date Rev <br /> 981.80 LBS 20 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES <br /> (Mod�ieweignt.rao"�t;agsystemwe;gnt� MID CLAMPS 28 MID CLAMPS UFO Initial Desi n 12111/24 00 <br /> Weight at Each Attachment Point WITH NEW(10)-AP SYSTEMS DS3-S INVERTERS. g <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH (Arrayweignt/NumberofAnacnmentPoian 17.38 LBS END CLAMPS 24 END CLAMPS STOPPER SLEEVE <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED Module Area(67.87"x44.64") 21.04 SgFt GROUNDING LUG 12 GROUNDING LUG ® =FIRE PATHWAY <br /> WITHIN 3FT OF AC DISCONNECT. Total Array Area 420.79 SgFt <br /> Distributed Load 2 33 Per Signature with Seal <br /> NOTE . (Total System Weight/Total Array Area) Sg Ft ❑O =ROOF OBSTRUCTIONS <br /> ATTIC RUN-YES Total Roof Area 2303 SgFt • =ATTACHMENT POINTS <br /> ATTIC FAN-NO Total Percentage or Roof Covered 18 27% <br /> Total Array Area RoofArea)N00 <br /> SHUTDOWN-NO =RAFTER <br /> -—- =RACKING SYSTEM <br /> —— =ATTIC RUN Project Name& <br /> Address <br /> Y <br /> =CONDUIT ATTIC RUN JUNCTION BOX <br /> W <br /> U <br /> Z <br /> u1 <br /> LL NEW PV ATTACHMENTS AT 4'-0"O.C. j ROOF SECTIONS w > o <br /> 1'-7" 71 18'-11" 4'-6" 15'-1" - 16'-11" 7'-6" 4'-10" RooFao, MODULE-12 cUn 0 ¢ z a <br /> N 0 SLOPE-27° < Q i Z <br /> 0 z AZIMUTH-180° U � F z J <br /> A 18"FIRE SETBACK" z Q MATERIAL-COMPOSITE SHINGLE Z w w O <br /> "FI A p TRUSS SIZE&SPACING-2"X4"@ 24"O.C. W w <br /> 18"FIRE SETBACK,/;a W cy LU <br /> / RooF#oz MODULE-08 <br /> z Z c14 w <br /> I Ll I I I I I I I I I U O SLOPE-27° <br /> 0 E m U W AZIMUTH-180° Q <br /> 0 1 w MATERIAL-COMPOSITE SHINGLE Y <br /> 0 CV TRUSS SIZE&SPACING-2"X4"@ 24"O.C. <br /> I i i I I ❑II I I I CV <br /> ��,, <br /> /r I -i, X' <br /> p o� QF Sheet Name <br /> 01 <br /> o sF�TBy SITE PLAN <br /> �y �� <br /> I I I O AC C 11 I I I I I I I I I �i,- <br /> ROOF#02 Sheet Size <br /> RooF#01 ANSI B <br /> 11" X 17" <br /> NEW AC COMBINER PANEL <br /> N Sheet Number <br /> NEW PV AC DISCONNECT GROUPED ��� <br /> 1�Inl ryt„/Nyr7� <br /> WITH SERVICE EQUIPMENT(VISIBLE, ' PV 1 .1 <br /> LOCKABLE,LABELED) <br /> EXISTING INTERIOR MAIN SERVICE PANEL <br /> &POINT OF INTERCONNECTION.TIED TO \ <br /> EXTERIOR UTILITY METER#76 375 586 <br /> CIRCUIT(S) <br /> 1 SITE PLAN CIRCUIT#1 - 10 MODULES WITH 05 MICROINVERTERS <br /> PV 1.1 SCALE:1/8"=V-0" CIRCUIT#2- 10 MODULES WITH 05 MICROINVERTERS <br />