7/8" MINIMUM CONDUIT HEIGHT SERVICE DISCONNECT TO BE MINIMUM WIRE SIZES CALLED OUT. AHJ STAMP <br /> LOCATED WITHIN 10FT OF THE USE OF LARGER WIRE IS <br /> ABOVE ROOF SURFACE UTILITY METER ACCEPTABLE. <br /> METER#:1000408852 <br /> TO UTILITY GRID <br /> L1 L2 N <br /> (N)SERVICE DISCONNECT: LINE (E)BI-DIRECTIONAL ELECTRICAL STAMP <br /> VISIBLE,LOCKABLE,LABELED UTILITY METER <br /> 200A FUSED,(2)200A FUSES, M 1-PHASE,3-W, ELECTRICAL ONLY <br /> 240V,NEMA 3R,UL LISTED 120V/240V <br /> (N)FRANKLIN aGATE X 200A, (SQUARE D D224NRB) LOAD �x�MAS <br /> PV RAPID SHUTDOWN/ (N)E-STOP <br /> NEMA 3R,120/240V A L1 L1 <br /> ESS DISCONNECT BUTTON (INSIDE GARAGE) L2 L2 <br /> O N N <br /> WASI�T <br /> r- GATEWAY �771 G �LJO ! 'v 1t,r.� tiJ` <br /> PV 30A/2P 2 _ 3 �' •"q <br /> YUKON SERIES SEG-410-BMD-HV eTl (3)#4/0 AWG AL (3)#410 AWG AL <br /> ESS 60A/2P (1)#4 EGC AL <br /> 15 MODULES AND 5 MICROINVERTERS IN BRANCH CIRCUIT 1 MANUFACTURER <br /> PROVIDED TRUNK '?o029�3 <br /> CABLE <br /> .... (N)JUNCTION BOX (2)#10 AWG I �"S <br /> I 600V,NEMA 3R (1)#10EGC I SInNAGF� <br /> UL LISTED <br /> L1 GEC <br /> N BONDED EXISTING GROUNDING <br /> ELECTRODE SYSTEM Signed 12/19/2024 <br /> (3)HOYMILES HM-150ONT[240V] (1)HOYMILES HM-70ONT (1)HOYMILES HIM-35ONT I _ <br /> MICROINVERTERS ONE UNDER [240V]MICROINVERTERS [240V]MICROINVERTERS I PROJECT NAME <br /> EVERY FOUR MODULES ONE UNDER EVERY TWO ONE UNDER EVERY L(L E �3)#4 EGC AL L <br /> MODULES MODULES �T/ AARON ANTON <br /> #6 AWG BARE CU — <br /> (415)994-9364 <br /> COMMUNICATION J 200E) AARONJANTON@GMAIL.COM <br /> -- CABLE -- 5829 GLENWOOD AVE, <br /> EVERETT, WA 98203 <br /> (N)FRANKLIN Leo APN#: 00436800000701 <br /> aPOWER2 No o AHJ: CITY OF EVERETT <br /> 15KWH,10KW G o 0 <br /> (INSIDE GARAGE) (3)#6 AWG THWN-2 N G UTILITY: SNOHOMISH PUD <br /> (1)#10 AWG THWN-2 GRND (E)200A MAIN SERVICE <br /> 3/4"EMT CONDUIT PANEL 120/240V,1-PHASE REVISIONS <br /> (BACKUP LOADS) <br /> REV DESCRIPTION DATE <br /> SHEET TITLE <br /> ELECTRICAL <br /> DESCRIPTION FORMULA RESULT DIAGRAM <br /> PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=((03 x 5.99)+(01 x 2.9)+(01 x 1.45))A x 1.25 27.90A (SELECTED OCPD =30A) DRAWN DATE 12/15/2024 <br /> EXPECTED <br /> TEMP QTY OF CURRENT CONDUIT FILL MINIMUM WIRE GAUGE& CONDUCTOR CONDUCTOR REQUIRED CIRCUIT ADJUSTED NEUTRAL GROUND WIRE DRAWN BY TSD <br /> WIRE ID o DERATE CARRYING CONDUIT SIZE AMPACITY @ AMPACITY @ CONDUCTOR AMPACITY CONDUCTOR CONDUCTOR <br /> WIRE TEMP( C) (90°C) CONDUCTORS DERATE (TBD ON SITE) TYPE 90°C(A) 75°C(A) (A) AMPACITY @ 90°C(A) SIZE&TYPE SIZE&TYPE SHEET NUMBER <br /> 1 26 1 2 0.8 3/4" #10 THWN-2 40 35 27.90 32.00 NONE #10 THWN-2 <br /> 2 1 26 1 1 1 3 1 1 1 2" 1 #4/0 THWN-2-AL 1 205 185 1 200.00 1 205.00 1#4/0 THWN-2-AL #4 THWN-2-AL PV-04 <br /> 3 1 26 1 1 1 3 1 1 1 2" 1 #4/0 THWN-2-AL 1 205 185 1 200.00 1 205.00 1#4/0 THWN-2-AL NONE <br />