Laserfiche WebLink
DATASHEET <br /> FFRaNKLINWIA <br /> Franklin Home Power Solution <br /> aGate 12 <br /> . yean: . <br /> y Whole Home Backup <br /> Intelligent energy management system r <br /> x <br /> Serves as the controller for all home power sources by interconnecting solar, Z DC <br /> grid,batteries,and a standby generator to supply electricity to the home. O <br /> Seamlessly transitions the home supply from grid power to backup power so <br /> Q <br /> ` Generator(Optional) <br /> that always-on appliances,such as the refrigerator and network router,will solar Panels Sotarinverter aGate ;S ' <br /> not be affected when grid goes down. ! -------- <br /> ' V # 000000 <br /> M <br /> - 1 <br /> FranklinWH App <br /> Utility Meter Utility Grid <br /> I <br /> i <br /> I <br /> __ Smart Circuits(Optional) I H <br /> ✓ Micro-grid interconnect device(MID) ✓ Compatible with micro and string solar inverter --T-------------T-------' FIE] <br /> ✓ Integrated PV and grid metering ✓ Optional Smart-Circuits Module lunnu <br /> V Auto load-shedding `� Optional Generator Module � Main Panel Backup Loads <br /> EV Charger Pool Pump Air Conditioner aPpwer <br /> PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS <br /> Coupling AC-coupled Dimensions(H x W x D) 315(800 mm x 5in mm7xn 6.3 160 m n <br /> Nominal AC Voltage 120/208 V,120/240 V.60 Hz <br /> Phase 2 W+N+PE Weight 50 lb(23 kg) <br /> aPower Over Current Protection Device 100AMax Mounting Wall mount or floor mount Partial Home Backup <br /> Solar Input Over Current Protection Device 80 A Max <br /> 6.3 in <br /> Backup Load Port Over Current Protection 21.7 in (160 mm) 21.7 In <br /> Device 200 A Max <br /> �' (55o mm) 'I— I- -1_ P (sso mm) <br /> Generator Over Current Protection Device 200 A Max 6.3 In 5 <br /> r--- - <br /> Opt.a1x80A Max @208V/240V&1 J _(160 mm) � AC i <br /> Smart Circuits Over Current x 50 A Max @ 208 V/240 V r"w7 <br /> Protection Device Solar Panels Solar Inverter aGate r Generator(Optional) <br /> Opt.b1x80AMax@2D8V/240V&2 r <br /> x50A Max @120V r <br /> 31.5 in 31.5 in � <br /> Maximum Supply Fault Current 20 kA (800 mm) (800 mm) _ -------% <br /> Busbar Rating 280 A Q QS 000000 <br /> Work Modes Self-Consumption.Time of Use.Emergency Backup Q M <br /> ------------------ <br /> Communications Ethernet/4G/Wifi U <br /> Backup Loads Main Panel i Utilit Meter Utllit Grid <br /> User Interface Franklin App _ _ — I ranklil App I y y <br /> I <br /> Warranty 12 years <br /> i <br /> I <br /> Smart Circuits(Optional) oo - <br /> COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS f-- _ £� <br /> UL 1741.UL 1741 PCS.UL 67.UL 869A.UL 916, Enclosure Type NEMA 3R Certifications � <br /> Inuun <br /> CANlCSA C22.2 No.107.1-16.CSA C22.2 No.29,CSA C22.2 No.0.19 <br /> Seismic AC 156.OSHPD,IEEE 693-2005(high) I I I I IIII I <br /> Operating Temperature -4"F to 122°F(-20°C to 5o°C) � 111111111 Non-backup Panel Non-essential <br /> Operating Humidity(RH) Up to 100%RH,condensing EV Charger Pool Pump Air Conditioner aPower <br /> Environmental California Proposition 65 Altitude Maximum 9,843 ft 3,000 m g P <br /> ROHS Directive 2011/EU ( ) <br /> Emissions FCC Part 15 Class B.ICES 003 Environment Indoor and outdoor rated <br /> Address:1731 Technology Dr.,Suite 530 San Jose.CA 95110 Telephone:+1 888-837-2655 Email:infol'�frankllnwh.com Webeite:wwwSranklinwh.con-, h a' <br /> t.Generator Module is optional 9Y IPA <br /> 2,Smart Circuit Module Is optional. Copyright 2324 FranklinWH Energy Stange Ina Ali rights re_�rved Tne F*anuin logo F�nklinwl.aria omer traoernarks or Service names are the trademarks of F,anklinWH Energy Storage Inc <br /> 3.Sections from these standards were used during the safety evaluation and included in the UL 1741 listing The document is for informational purposes only,Baia subject to change. 2024-04-D3 ❑� i'�� <br /> WWW.FRANKLINWH.00M WWW.FRANKLINWH.00M Fi=UBNKLINW1A <br />