Laserfiche WebLink
EZf SOLARJB- 1 • 2 , JB- 1 _X L E Zf SOLAR PHONE;385-202-4150 <br /> Specification Sheet making solar slmple WWW.EZSOLARPRODUCTS.COM BLUE RAVEN <br /> making solar simple. PV Junction Box for Composition/Asphalt Shingle Roofs SOLAR <br /> A. System Specifications and Ratings <br /> ITEM N0. PART NUMBER DESCRIPTION OTY sizE DWG.No. REV <br /> • Maximum Voltage: 1,000 Volts 1 JB-1.2 BODY POLYCARBONATE 1 B JB-1.2 <br /> WITH UV INHIBITORS SCALE:1:2 WEIGHT:1.45 LBS SHEET 1 OF 3 <br /> • Maximum Current: JB-1.2: 80 Amps; JB-1.XL: 120 Amps <br /> • Allowable Wire: 14 AWG —6 AWG POLYCARBONATE <br /> 2 JB-12 LID WITH UV INHIBITORS 1 TORQUE SPECIFICATION: 15-20 LBS <br /> • Spacing: Please maintain a spacing of at least '/2" between uninsulated live parts and fittings for <br /> conduit, armored cable, and uninsulated live parts of opposite polarity. 3 #10 X 1-114"PHILLIPS 6 CERTIFICATION: UL 1741,NEMA 311 <br /> • Enclosure Rating: Type 3113 PAN HEAD SCREW CSA 022.2 NO.290 <br /> • Roof Slope Range: 2.5— 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS <br /> • Max Side Wall Fitting Size: 1" PAN HEAD SCREW <br /> • Max Floor Pass-Through Fitting Size: 1" <br /> • Ambient Operating Conditions: (-35°C) - (+75°C) <br /> • Compliance: <br /> - JB-1.2: UL1741, CSA C22.2 No. 290; JB-1.XL: UL1741, CSA C22.2 No. 290 EIV�s <br /> -Approved wire connectors: must conform to UL1741, CSA C22.2 No. 290 <br /> Intertek <br /> • System Marking: Interek Symbol and File#5019942 5019942 / <br /> • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion <br /> between components, components that are found to be affected are to be replaced immediately. <br /> Table 1:Typical Wire Size,Torque Loads and Ratings <br /> 1 Conductor 2 Conductor Torque <br /> Type NM I Inch Lbs Voltage Current - •� <br /> ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 6.2-8.85 600V 30 amp �-- • <br /> ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 am <br /> ABB ZS16 terminal block 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp <br /> # <br /> [279.68mm] [17li.qtr nn] <br /> N <br /> ABB M 11.01 in 0:mn6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 60oV 50 amp I I I <br /> Ideal 452 Red Z"' 8-18 awg Sol/Str Self-Torque Self-Torque 600V <br /> Ideal 451 Yellow w e o 10-18 awg Sol/Str Self-Torque Self-Torque 600V I I I S ® L A R I I I <br /> Ideal, In-Sure 1,,h,,s°°""r 10 14 awg Sol/Str Self-Torque Self-Torque 600V <br /> WAGO, 2204-1201 10-20 awg 16-24 awg Sol/Str Self-Torque Self-Torque 600V 30 amp JB 1 2 III <br /> WAGO, 221-612 10-20 awg 10-24 awg Sol/Str Self-Torque Self-Torque 600V 30 amp <br /> Dottie DRC75 6-12awg Sol/Str Snap-In Snap-In I Patent,: aa,P�«.omae« <br /> 4-6 awg Sol/Str 45 1 <br /> ESP NG-53 10-14 awg Sol/Str 35 2000V <br /> ESP NG-717 4-6 awg Sol/Str 45 2000V 1 <br /> 10-14 awg Sol/Str 35 <br /> 4-6 awg Sol/Str 45 <br /> Brumall 4-5,3 10-14 awg Sol/Str 35 2000V [183.06mm] <br /> [72.53mm] <br /> 7.21 in 2.86in <br /> Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) [265.18mm] <br /> 10.44in <br /> Wires per terminal(pole) <br /> Wire size,AWG or t 2 3 4 or More <br /> kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) <br /> 14-10 (2.1-5.3) Not Specified - - <br /> 8 (8.4) 38.1 (1-1/2) <br /> 6 (13.3) 1 50.8 (2) - - - <br /> PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTYOF EZSOLAR. -� DRAWING NUMBER: <br /> ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. 50157 k <br /> 5015]OS <br /> EZf SOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COMJ" J" <br />