9821 21ST DR SE 2025-12-01
>
Address Records
>
21ST DR SE
>
9821
>
9821 21ST DR SE 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2025 8:20:04 AM
Creation date
11/20/2025 11:43:54 AM
Metadata
Fields
Template:
Address Document
Street Name
21ST DR SE
Street Number
9821
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ll (1) 10 AWG THHN/THWN-2 CU BLACK L1 (1) 10 AWG THHN/THWN-2 CU BLACK 3/41NCH Ll (1) 10 AWG THHN/THWN-2 CU BLACK 3/41NCH L1 (1) 12 AWG THHN/THWN-2 CU BLACK <br /> 4 L2 (1) 10 AWG THHN/THWN-2 CU RED L2 (1) 10 AWG THHN/THWN-2 CURED EMT* L2 (1) 10 AWG THHN/THWN-2 CU RED L2 (1) 12 AWG THHN/THWN-2 CU RED <br /> N (1) 10AWGTHHN/THWN-2CU WHITE G (1) IOAWGTHHN/THWN-2CU GREEN 2 G (1) 10AWGTHHN/THWN-2CU GREEN 1 G (1) 6AWGBARE,CU <br /> G (1) 10 AW G THHN/THWN-2 CU GREEN *TYPE OF CABLE MAY BE SUBSTITUTED FOR USE IN CONDUIT WHERE *TYPE NM(ROMEX)OR OF CABLE IS PERMITTED FOR INTERIOR OR <br /> 3/4 INCH EMT Exterior ELECTRICAL CODE PERMITS ATTIC RUNS AND SHALL BE USED WHEN ELECTRICAL CODE PERMIT ENPHASE Q-CABLE,2-WIRE,FREE AIR Exterior BLUE RAVEN <br /> SOLAR <br /> 1403 N 630 E <br /> Orem, Utah 84097 <br /> (800) 377-4480 <br /> BlueRavenSolar.com <br /> PRIMARY PV COMBINER BOX <br /> O c PRIMARY STRUCTURE <br /> AC DISCONNECT O QA (B)PV MODULES <br /> SAFETY SWITCH OB &MICROINVERTERS <br /> Utility Meter (E)125A Main Service Panel 30A NON-FUSIBLE (N)20A QD <br /> PV CIRCUIT 1 PV ARRAY 1 <br /> 8 MODULES ti ti ti <br /> OF 5 G - - ❑ 0 ❑GATEWAY --- 3 2 -I I 1 <br /> 15A I I <br /> (E) 125A I PV A RR AY 2 } <br /> I <br /> (EL) I - � � ❑ U <br /> N IGn� I LJ 1 00 N <br /> (EL) L1 I — J �~ O <br /> L2 <br /> yL Q `/' <br /> Op (D <br /> (EL) ---- -------------------------- — ------------------- J � 0 }--------- VO4 <br /> } <br /> (EL) I U <br /> to •— <br /> I > <br /> (PV)20A <br /> N � <br /> I ��N O 14— IL <br /> N <br /> I N > <br /> j 00 >. >_ <br /> E �Gx0C <br /> �I W A S 0 Z O <br /> G I t� V. > U <br /> --------------J t�� P 2 LU <br /> y <br /> N <br /> _` _ 1AY11i r cn E <br /> UNDERGROUND SERVICE V T r O <br /> 120/240 VAC,60 Hz <br /> 1 PHASE,3 WIRE 7 33��� q ) Q <br /> 8 4 a O <br /> DigiS �� e 2 3 - — Q <br /> INTERCONNECTION NOTES J o u n g h by Jou 1 ` �b 43 KWHH YT , z v' <br /> Utility Meter Number:56658433 . O <br /> Date:2025.01.10 2 <br /> V <br /> o Cho <br /> I ���_ <br /> Load Side Breaker,Interior MSP "- <br /> 10:03:46-05,00, <br /> v a 5 <br /> LEGEND PROJECT ID: <br /> (E) EXISTING (PV) PV BREAKER _ 1273929 <br /> (N) NEW (FIB) FACTORY INSTALLED BREAKER � <br /> 1 <br /> (EL) EXISTING LOADS SPD SURGE PROTECTIVE DEVICE __ PV DC SYSTEM SIZE: <br /> (RL) RELOCATED LOADS MI MECHANICAL INTERLOCK SNO. CO, 3.440 kW DC <br /> YSTEM <br /> EQUIPMENT NOTES EQUIPMENT DESCRIPTIONS ? ;�� • � .nr PVAcs2 6001kW AC <br /> O1 FINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER.MUST COMPLY WITH MAX QA PV MODULE:Siltab Solar SIL-430 QD,430 W DC,UL 1703/UL 61730 COMPLIANT 58 65k `v <br /> MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. ©MICROINVERTER:ENPHASE IQ8M-72-M-US,325 W AC(0.325 kW),1 PHASE,UL 1741 COMPLIANT ' 11 1 REVISIONS: <br /> O2 ©ROOFTOP JUNCTION BOX:EZ SOLAR JB-1.2 JUNCTION BOX QA <br /> O3 0 JUNCTION BOX:PVC 4 X 4 JUNCTION BOX Q <br /> O PV COMBINER BOX:ENPHASE COMBINER 5(X-IQ-AM1-240-5) B <br /> OQF SQUARE-D SAFTEY SWITCH 30A,2P,240VAC,NON-FUSIBLE(DU221 RB) <br /> © Q <br /> O 0 D <br /> (D �� DRAWN BY: <br /> 0 Jordan Davis <br /> O Q PLOT DATE: <br /> © _ January 9, 2025 <br /> OOM OTHER NOTES DRAWING TITLE: <br /> O9 GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. Electrical <br /> O <br /> ,o © 3-Line <br /> ® DRAWING NUMBER: <br /> 11 <br /> ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. PV5 <br /> O 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.