My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3328 FEDERAL AVE 2025-12-01
>
Address Records
>
FEDERAL AVE
>
3328
>
3328 FEDERAL AVE 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2025 8:26:07 AM
Creation date
11/20/2025 12:00:13 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3328
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MICROINVERTERS SPECIFICATION PV MODULE RATING @ STC Rooftop conductor ampacities designed in compliance with 120% RULE 0 <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8,Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), <br /> MICROINVERTER MODEL NO. DS3-S 310.16, Chapter 9 Table 4, 5, &9. Location specific BUS BAR RATING X 120%)- MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p _ infinity <br /> solar <br /> AC OUTPUT 640 W temperature obtained from ASHRAE 2017 data tables — MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER-POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 2.66 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA 98661 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP -5°C PHONE:1-800-818-0598 <br /> THIS PANEL IS FED BY MULTIPLE SOURCES INFINITY SOLAR.COM <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT NOM.MAX.POWER AT STC(PMAX) 410 WATT AMBIENT TEMP(HIGH TEMP 2%) 26°C (UTILITY AND SOLAR) <br /> REVISIONS <br /> WITHIN 10' OF UTILITY METER MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8 AC OUTPUT CURRENT 43A Description Date Rev <br /> NOTE : <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C NOMINAL AC VOLTAGE 240V Initial Design 1/22/25 00 <br /> ATTIC RUN -YES NOTE: (SOLAR PV SYSTEM EQUIPPED WITH CONDUCTOR TEMPERATURE RATE 90°C <br /> SHUTDOWN -NO RAPID SHUTDOWN) NEEDS TO BE LOCATED MODULE: (32)ZNSHINESOLAR ZXM7-SH108-410M POINT OF INTERCONNECT,SUPPLY SIDE <br /> WITHIN 3FT OF AC DISCONNECT. Signature with Seal <br /> INVERTER: (16)AP SYSTEMS DS3-S EXISTING 240V/200A BUS BAR RATING, <br /> (32)ZNSHINESOLAR ZXM7-SH108-410M MAIN SERVICE PANEL#01,SINGLE PHASE, <br /> (16)AP SYSTEMS DS3-S INVERTERS WITH A 200A MAIN BREAKER <br /> UTILITY COMPANY-SNOHOMISH COUNTY <br /> BRANCH 1-12 MODULES WITH 06 MICRO INVERTERS PUD NO.1 <br /> 320A SERVICE UTILITY METER#120 754 077 <br /> EXISTING <br /> BI-DIRECTIONAL <br /> f f f f f f f f f f f f (�) <br /> UTILITY METER, Project Name& <br /> L — J L — J L — J L — J L — J L = J 1-PHASE,3W, Address <br /> N N N N N LINE SIDE TAP "L' L2L2 FT' — 120V/240V <br /> ------- ------- ---------------- ------- ------ (N)125A COMBINER PANEL, (N)BLADE TYPE USING IPC <br /> BRANCH 2-10 MODULES WITH 05 MICRO INVERTERS 240V,3W,1-PHASE FUSIBLE AC DISCONNECT LU <br /> NEMA 3R 60A-2P 120/240VAC U <br /> (VISIBLE,LOCKABLE,LABELED) EXISTING LU <br /> z <br /> 200A E-{ 200A E-{ 0 <br /> 240V/200A BUS � <br /> (E)LOADS BAR RATING,SUB <br /> L4j (N)JUNCTION BOX 60A FUSES (E)LOADS Lu > C4 <br /> f f f f f f f f f f 600 V,NEMA 4 o a o Q <br /> T T PANEL, ¢ Q <br /> L J L J L J L J L J UL LISTED 20A <br /> � PHASE,WITH A N QQ Q z z <br /> 200A MAIN Of LU u.i <br /> ------- ---------------- ------- ----- u u 20A (E)LLOOAADS (E)LOADS BREAKER ? o OZ Q <br /> BRANCH 3-10 MODULES WITH 05 MICRO INVERTERS Lz L2 20A L1 � � � LU W <br /> 2 01 L2 W CV LU <br /> L2 L2FF of M LU <br /> u u N N O <br /> G N ----- — ---L2 L2 — -- --- <br /> f f f f f f f f f f I c j G G G <br /> L — J L — J L — J L — J L — J --- --- �— — ---- — L--- ---- ----- <br /> J EXISTING GROUNDING EXISTING GROUNDING <br /> 2 3 ) 4 ELECTRODE SYSTEM ELECTRODE SYSTEM <br /> Sheet Name <br /> 3-LINE <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE DIAGRAM <br /> TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPEWMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) <br /> Sheet Size <br /> #10\THWN\40A @90°C 20A 2 TRUNK CABLE 1.00 x 1.00 x 40A 40.00A 15.96A #6 AWG 20 0.28 ANSI B <br /> 06 x 2.66 x N/A = 15.96A 19.95A IN AIR 11"X 17" <br /> Sheet Number <br /> O06 x 2.66 x N/A = 15.96A 19.95A #10\THWN\40A @90°C 20A 6 3/4" EMT 1.00 x 0.80 x 40A 32.00A 15.96A #8 AWG 55 0.76 E 1 .1 <br /> 1.34< <br /> O16 x 2.66 x N/A = 42.56A 53.20A #6 \THWN \65A @75°C 60A 2 3/4" EMT 1.00 x 1.00 x 65A 65.00A 42.56A #8 AWG 10 0.15 2 <br /> 4 16 x 2.66 x N/A = 42.56A 53.20A #6 \THWN \65A @75°C 60A 3 3/4" EMT 1.00 x 1.00 x 65A 65.00A 42.56A #8 AWG 10 0.15 LJ __J <br />
The URL can be used to link to this page
Your browser does not support the video tag.