Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS MODULE, ARRAY WEIGHT (LOAD SYSTEM LEGEND <br /> SYSTEM SIZE: 13.120 kW DC NUMBER OF MODULES 32 ZNSHINESOLAR ZXM7-SH108-410M CALC'S) EXISTING INTERIOR MAIN SERVICE PANEL&POINT V <br /> 10.240 kW AC NUMBER OF INVERTER 16 AP SYSTEMS DS3-S � OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinitysolar <br /> MODULE TYPE&AMOUNT: (32)ZNSHINESOLAR ZXM7-SH108-410M Number of Modules 32 METER#120 754 077. <br /> MODULE DIMENSIONS: (L/W/H)67.87"/44.64"/1.8" COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER Module Weight 45.19 LBS <br /> 816L125RP NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS <br /> INVERTER: (16)AP SYSTEMS DS3-S Total Module(Array)Weight 1446.08 LBS AC 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 60A FUSIBLE AC DISCONNECT,240V LOCATED WITHIN 10'FROM THE UTILITY METER VANCOUVER WA 98661 <br /> CHIKO AL ROOF HOOK#167 Number of Attachment point 88 PHONE:1-800-818-0598 <br /> NUMBER OF ATTACHMENTS 88 CHIKO 1 ROOF <br /> Mounting System Weight 1.5 LBS © NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITY SOLAR.COM <br /> (Per Module) <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT RAILS 19 CHIKO 518 RAIL 4200MM Mounting System Weight 132.00 LBS REVISIONS <br /> WITHIN 10' OF UTILITY METER RAIL SPLICE 8 SPLICE KIT Total System Weight 32 NEW W(16)ZINSHI ESOLAR E M7-S 3-S INVERTERS. <br /> MODULES <br /> y g 1578.08 LBS WITH NEW(16)-AP SYSTEMS DS3-S INVERTERS. Description date Rev <br /> MID CLAMPS 44 MID CLAMPS/UFO (Modute Weight,Moo Mg,SyetemWeight) Initial Design 1/22/25 00 <br /> END CLAMPS 40 END CLAMPS/STOPPER SLEEVE Weight at Each Attachment Point 16.43 LBS <br /> NOTE : (Array Weight/Numbe,ofAttachmentPoint) El =FIRE PATHWAY <br /> ATTIC RUN-YES GROUNDING LUG 20 GROUNDING LUG Module Area(67.87"x44.64") 21.04 SgFt <br /> ATTIC FAN-NO Total Array Area 673.27 SgFt <br /> SHUTDOWN-NO Distributed Load Per ❑O =ROOF OBSTRUCTIONS Signature with Seal <br /> 2.34 <br /> (Total system weight/Total Array Area) Sq Ft <br /> =ATTACHMENT POINTS <br /> Total Roof Area 2224 SgFt <br /> ° Total Pearce nta ge or Roof Covered 30.27% =RAFTER <br /> TatelArmy <br /> -—- =RACKING SYSTEM <br /> —— =ATTIC RUN Project Name& <br /> Y <br /> U u Address <br /> �m )O� =CONDUIT ATTIC RUN JUNCTION BOX <br /> w W <br /> U <br /> Z <br /> M W <br /> j ROOF SECTIONS o w o <br /> 18"FIRE SETBACK W > `~ <br /> 18"FIRE SETBACK YI w _J ROOF#01 MODULE-32 N Q Q z <br /> — Q U) Q SLOPE-19' W � � Z <br /> "FIR S T O O/ AZIMUTH-180' Q W w <br /> co ~ 18 I ck K w w MATERIAL-COMPOSITE SHINGLE LL W O <br /> 1 "FIRE ETBA K M `n TRUSS SIZE&SPACING 2"X4"@ 24"O.C. WF N w w <br /> w c`i w MA LL <br /> ❑ U w O <br /> 1 1 1 0 <br /> ° N <br /> Q M <br /> °I M <br /> � INil <br /> _ i <br /> I❑ Sheet Name <br /> cCOi I I I I I I I� I I �I I <br /> 1 1 1 1 1 4 7 1 SITE PLAN <br /> 1 1 1° 1 rn o <br /> ° �1 <br /> Sheet Size <br /> C <br /> L 7'-10" 54'-11" O AC 1'3" ANSI B <br /> NEW PV ATTACHMENTS AT 4'-0"O.C. 11" X 17" <br /> ROOF#01 <br /> NEW AC COMBINER PANEL Sheet Number <br /> EXISTING INTERIOR MAIN SERVICE PANEL NEW PV AC DISCONNECT GROUPED N PV 1 .1 <br /> &POINT OF INTERCONNECTION.TIED TO WITH SERVICE EQUIPMENT ���� �°')u�y�,��i����l„"('°�"y'�°��.,, <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH EXTERIOR UTILITY METER#120 754 077 (VISIBLE,LOCKABLE,LABELED) � <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED <br /> WITHIN 3FT OF AC DISCONNECT. CIRCUIT(S) <br /> e <br /> CIRCUIT#1 - 12 MODULES WITH 06 MICROINVERTERS <br /> 1 SITE PLAN CIRCUIT#2- 10 MODULES WITH 05 MICROINVERTERS <br /> Pv,., SCALE:1/8"=V-0" ® CIRCUIT#3- 10 MODULES WITH 05 MICROINVERTERS <br />