Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS MODULE, ARRAY WEIGHT (LOAD SYSTEM LEGEND <br /> SYSTEM SIZE: 8.200 kW DC <br /> NUMBER OF MODULES 20 ZNSHINESOLAR ZXM7-SH108-410M CALLS) 0 <br /> 6.400 kW AC EXISTING INTERIOR MAIN SERVICE PANEL&POINT <br /> MODULE TYPE&AMOUNT: (20)ZNSHINESOLAR ZXM7-SH108-410M NUMBER OF INVERTER 10 AP SYSTEMS DS3 S Number of Modules 20 OF INTERCONNECTION.TIED TO EXTERIOR UTILITY �rlfllllt�/`_OG I <br /> MODULE DIMENSIONS: (L/W/H)67.87'744.64"/1.8" COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER Module Weight 45.19 LBS METER#55 281728. <br /> 816L125RP INFINITY HOME SOLUTIONS <br /> INVERTER: (10)AP SYSTEMS DS3-S Total Module(Array)Weight 903.80 LBS 6405 E MILL PLAIN <br /> AHJ: CITY OF EVERETT AC DISCONNECT 1 60A NON FUSIBLE AC DISCONNECT,240V NEW VISIBLE,LOCKABLE,LABELED DISCONNECT VANCOUVER WA98661 <br /> Number of Attachment point 52 AC LOCATED WITHIN 10'FROM THE UTILITY METER PHONE:1-800-818-0598 <br /> NOTE : <br /> NUMBER OF ATTACHMENTS 52 CHIKOK-FT - ROOF HOOK#167 Mounting System Weight <br /> C -FTS167RT2 1.5 LBS INFINITY SOLAR.COM <br /> (Per Module) <br /> ATTIC RUN-YES RAILS 11 CHIKO 518 RAIL 4200MM Mounting System Weight 78.00 LBS © NEW DEDICATED PV SYSTEM COMBINER PANEL. REVISIONS <br /> ATTIC FAN-NO RAIL SPLICE 6 SPLICE KIT Total System Weight Description Date Rev <br /> SHUTDOWN-NO MID CLAMPS 28 MID CLAMPS/UFO (ModuleWelght-MountingSystemWelght) 981.80 LBS <br /> 20 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES Initial Design 2/20125 00 <br /> END CLAMPS 24 END CLAMPS/STOPPER SLEEVE Weight at Each Attachment Point 17.38 LBS WITH NEW(10)-AP SYSTEMS DS3-S INVERTERS. <br /> (Array Weight/Number o/Attachment Point) <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT GROUNDING LUG 12 GROUNDING LUG Module Area(67.87"x44.64") 21.04 SgFt <br /> WITHIN 10' OF UTILITY METER Total Array Area 420.79 SgFt ® =FIRE PATHWAY <br /> Distributed Load Per Signature with Seal <br /> (Total System Weight/Total Array Area) 2.33 SgFt ❑0 =ROOF OBSTRUCTIONS <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH 1416 HOLLOW DALE PL Total Roof Area 2234 SgFt <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED Total Percentage or Roof Covered u • =ATTACHMENT POINTS <br /> WITHIN 3FT OF AC DISCONNECT. FRONT OF HOUSE Total Array Area/Total RootAlau)l0o 18.84/0 <br /> -—- =RAFTER <br /> -—- =RACKING SYSTEM <br /> NEW AC COMBINER PANEL Project Name& <br /> —— =ATTIC RUN Address <br /> NEW PV AC DISCONNECT GROUPED <br /> WITH SERVICE EQUIPMENT(VISIBLE, )0( =CONDUIT ATTIC RUN JUNCTION BOX <br /> LOCKABLE,LABELED) I A K U <br /> EXISTING INTERIOR MAIN SERVICE PANEL Z <br /> LU <br /> &POINT OF INTERCONNECTION.TIED TO ROOF SECTIONS 0 <br /> EXTERIOR UTILITY METER#55 281 728 I w w o <br /> AC I of <br /> ROOF#o, MODULE-20 J Q Z Z <br /> o �0 0 SLOPE 0O F- ui <br /> co m AZIMUTH-180' Q ~ Z <br /> Lu LU MATERIAL-COMPOSITE SHINGLE 2 =O O w <br /> U) � RAFTER SIZE&SPACING-2"X6"@ 24"O.C. W m w <br /> o w <br /> � � <br /> NEW PV ATTACHMENTS AT 4'-0"O.C. <br /> I <br /> I <br /> 12'-3" 22'-8" 2' 11" 23�-11" 3'-3" <br /> Sheet Name <br /> 1 " I S BAC <br /> 1 "FIRE ETBACK SITE PLAN <br /> 1 <br /> I I I I I O I I Sheet Size <br /> ANSI B <br /> N 11ll X 17" <br /> 1 1 1 <br /> O y�"����t�4hhp)^q"i� Sheet Number <br /> O <br /> 1 1 1 1 1 1 d - PV 1 .1 <br /> 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 <br /> 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 <br /> 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 <br /> 6h, <br /> ROOF#01 CIRCUIT(S) <br /> 1 SITE PLAN CIRCUIT#1 - 10 MODULES WITH 05 MICROINVERTERS <br /> Pv,., SCALE:1/8"=1'o° CIRCUIT#2- 10 MODULES WITH 05 MICROINVERTERS <br />