Installation Model J1 Sprinkler Wrench <br /> Model JL14 and JL17 sprinklers are intended for installation in <br /> accordance with NFPA 13 and FM Loss Prevention Data Sheets <br /> 2-0 and 8-9,as well as the requirements of any Authorities Havingu.' su., <br /> Jurisdiction.See Table B for information on NFPA and FM Global <br /> design criteria for the Model JL14 and JL17 sprinklers. <br /> For threaded sprinklers only, use the Model J 1 sprinkler wrench for <br /> removal and installation.Any other type of wrench may damage <br /> the sprinkler.A grooved wrench boss is provided on the sprinkler to Guarantee <br /> limit the potential for the wrench to slip during installation. <br /> For the Reliable Automatic Sprinkler Co.,Inc.guarantee,terms,and <br /> When handling sprinklers,hold sprinklers only on frame arms and conditions,visit www.reliablesprinkler.com. <br /> do not apply any force on the link assembly. Model JL14 and JL17 <br /> sprinklers should be tightened between 14-40 ft-lbs(19-54 Ordering Information <br /> N•m)torque.Sprinklers not tightened to recommended torque may <br /> cause leakage or impairment of the sprinkler. Damaged sprinklers Specify <br /> must be replaced immediately. Sprinkler: [JL14] [JL17] <br /> • Temperature Rating: [165°F(64°C)][212°F(100°C)] <br /> Caution:When handling sprinklers, hold sprinklers only by the End Connection: [3/4" NPT] [IS07-1 R3/4(BSPT)] <br /> frame arms and do not apply any force on the link assembly. <br /> Optional <br /> Maintenance S-3 Water Shield(threaded sprinklers only) <br /> Model JL14 and JL17 ESFR Sprinklers should be inspected and <br /> the sprinkler system maintained in accordance with NFPA 25. Do <br /> not clean sprinkler with soap and water,ammonia or any other <br /> cleaning fluid. Replace any sprinkler that has been painted(other <br /> than factory applied)or damaged in any way. A stock of spare <br /> sprinklers should be maintained to allow quick replacement of <br /> damaged or operated sprinklers. Prior to installation,sprinklers <br /> should be maintained in the original cartons and packaging until <br /> used,to minimize the potential for damage to sprinklers that would <br /> cause improper operation or non-operation. <br /> Once operated,automatic sprinklers cannot be reassembled and <br /> reused. New sprinklers of the same size,type and temperature <br /> rating must be installed.A cabinet of replacement sprinklers should <br /> be provided for this purpose. <br /> Listings and Approvals <br /> 1. UL Listed and ULC Certified for Canada(cULus) <br /> 2. FM Approved(FM) <br /> 3. VdS Certified(VdS) <br /> 4. Loss Prevention Certification Board Approved(LPCB) <br /> 5. CNBOP-PIB Technical Approval(CNBOP-PIB) <br /> 6. CE(2809-CPR-M0015,2809-CPR-M0016) <br /> rn <br /> ti <br /> M <br /> O <br /> ti <br /> O <br /> O <br /> O <br /> O <br /> Bulletin 019 Page 5 of 5 z <br /> January 2024 Reliable www.reliablesprinkler.com a <br />