6617 ASSOCIATED BLVD 2024 AMAZON Plans 2025-12-01
>
Address Records
>
ASSOCIATED BLVD
>
6617
>
AMAZON
>
Plans
>
6617 ASSOCIATED BLVD 2024 AMAZON Plans 2025-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 8:19:58 AM
Creation date
12/1/2025 8:13:55 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6617
Tenant Name
AMAZON
Permit
K2411-003
Year
2024
Notes
9 SPRINKLER HEADS MODIFICATION TO ACCOMMODATE RTU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: K2411-003 <br /> Site Address: 6617 Associated Blvd <br /> Applicant: Tang!Norris <br /> Application Date: 1110512024 <br /> Description: 9 Sprinkler heads for rooftop units <br /> Review Date: 11/06/2024 <br /> A B c E K L EV <br /> FITTER/LISTER NOTES <br /> ERETT <br /> 1. ALL HANGERS ARE TO BE PER DETAIL"TB"U.N.O. Everett Fire Dept.Permit Review <br /> 2. SEND 90 FT.OF BULK 3/8"ATR FOR CTS HANGER RODS. Status:Approved <br /> 3. EXCLUDING WORK ON OVERTIME OR AFTER HOURS. Reviewed By:kbrown <br /> 11/06/2024 8:38:57 <br /> 4. EXCLUDING RELOCATING OR MODIFYING THE EXISTING SPRINKLER AM <br /> SYSTEM TO ACCOMMODATE THE WORK OF OTHER TRADES. <br /> GENERAL NOTES <br /> 1. ALL STEEL PIPE TO BE AS FOLLOWS UNLESS NOTED OTHERWISE:- - - - - A <br /> �\ / STEEL PIPE ASTM A-795 OR BETTER HT of <br /> u�� III///■\\\ PIPE SCHEDULE WALL INTERNAL END PREP TYPES ALLOWED c='_N <br /> SIZE THICKNESS DIAMETER wE�RrPIPE anunrvs <br /> ° • O I 1 40 0.133 1.049 THREADED,CUT GROOVED,ROLL GROOVED,PLAIN END,POLISHED WA 2.05 0.044 <br /> 2 FLOW PIPE 0.09s 2.185 ROLL GROOVED,POLISHED,PLAIN END(FOR BUTT WELDING) 3.94 0.198 <br /> C <br /> 2.5 ° ° - ** WALL THICKNESS PER NFPA#13 <br /> ";�ILL� <br /> 2. ALL GROOVED COUPLINGS TO BE RIGID TYPE UNLESS NOTED(III)WHICH ARE FLEXIBLE. <br /> SE DETAIL(TYP.) - 2.5 2.5 2.5 SCOPE OF WORK <br /> 3 - - - - - - - - - - _ - - - <br /> 2.5 2.5 2.5 2.5 <br /> SEE DETAIL(FYP.)� SMITH FIRE SYSTEMS(SFS)WILL MODIFY THE EXISTING SPRINKLER SYSTEM TO <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - ACCOMMODATE THE NEW ROOFTOP UNIT. <br /> 2.5 z.s z.s <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CLARIFICATIONS: <br /> 1. ALL AREAS PROTECTED BY A WET PIPE SYSTEM MUST BE MAINTAINED AT 40°F IN <br /> - - - - - - - - - - <br /> 2. SPRINKLER MODIFICATIONS ARE BASED UPON HAVING ADEQUATE PRESSURE <br /> - - - - - - - - - AVAILABLE AT THE POINT OF CONNECTION <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> 3. MATERIALS INSTALLATION AND DESIGN PER NFPA 13 STANDARDS AS SELECTED BY <br /> SFS. <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4. ROUGH-IN OF NEW SPRINKLER DROPS MUST BE COMPLETED BEFORE NEW WALLS OR <br /> CEILINGS ARE INSTALLED. <br /> 4 _ <br /> mri EXCLUSIONS: <br /> .5 <br /> 1. SAFE OFF OR A SEPARATE DEMO TRIP IS NOT INCLUDED LINO. M <br /> <,7 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2. FLOOR MUST BE FREE AND CLEAR OF MERCHANDISE,STOCK,RACKING OR n < <br /> f° CONSTRUCTION MATERIALS TO ALLOW FOR ACCESS TO PIPE AT THE STRUCTURE. o m �' <br /> a^ 3. CUTTING PATCHING OR FIRE CAULKING OF WALLS,CEILINGS,OR FLOORS <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4. ACCESS PANELS OF ANY KIND. _ <br /> 5. DOH,FM,INSURANCE,OR OTHER OUTSIDE REVIEW REQUIREMENTS,APPROVALS OR _q <br /> FEES <br /> 3. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6. HEAT TRACE OR INSULATION OF ANY KIND X 0 <br /> N m 7. ANY WORK OUTSIDE THIS TENANT SPACE (D <br /> ro - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8. PAINTING OR LABELING OF PIPE. <br /> 5 9. REPLACEMENT OF PAINTED,DAMAGED,OR CORRODED SPRINKLERS. (D C <br /> 10. ELECTRICAL OR ALARM WORK OF ANY KIND. :E -+ <br /> 11. BACKFLOW INSTALLATION,MODIFICATION,OR CERTIFICATION(IF REQUIRED) CD M <br /> 12. REPAIRS OR MODIFICATIONS TO THE EXISTING SYSTEM BEYOND THE SCOPE CL < <br /> DESCRIBED ABOVE. p M <br /> 13. FIRE WATCH OR TEMPORARY SPRINKLER PROTECTION DURING CONSTRUCTION. (D <br /> 14. MODIFICATIONS REQUIRED TO ACCOMMODATE THE WORK OF OTHER TRADES 11� <br /> - - - - - - - - - - - - - - - - - - 15. STRUCTURAL ANALYSIS,SEISMIC INVESTIGATION,OR PE REVIEW LINO 0) <br /> 16. UNDERGROUND WORK OF ANY KIND (D <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -. - <br /> DESIGN CRITERIA: --2.5 25 2.5 2.5 � rF <br /> - - - cn <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PER NFPA 13 2019 AND THE CITY OF EVERETT <br /> FQEI <br /> 2.5 z.5 z.s EXISTING CRITERIA: PQ <br /> ESFR STORAGE N n° <br /> 6 SEE DETAIL(TVP.)� - - - - - - - - (D <br /> SEE DETAIL(TYP.)1 - - - - - TENANT IMPROVEMENT: <br /> ° ° ° o N <br /> 2.5 2.5 2.5 -2.5 <br /> THIS PROJECT IS A TENANT IMPROVEMENT. THIS FACILITY HAS ALREADY BEEN PROTECTED <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BY A FIRE SPRINKLER SYSTEM. SMITH FIRE SYSTEMS IS ADDING AND/OR RELOCATING <br /> SPRINKLER HEADS TO ACCOMMODATE THE NEW TENANT WALL,CEILING,LIGHTING,AND <br /> HVAC LAYOUT. ALL WORK WILL BE DONE WITHOUT AFFECTING THE CAPABILITY OF THE <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING SYSTEM;THEREFORE,NO NEW HYDRAULIC CALCULATIONS ARE NECESSARY. <br /> 7 71 <br /> AREA OF WORK M <br /> PIPE PLAN s 6L <br /> Me N, <br /> 'C 4 <br /> °' 9. RISER <br /> 'ROOFTOP UNIT <br /> bZ <br /> ROOF PROTECTION ROOF DECK <br /> - - FedEx Ship Center <br /> EXISTING BRANCH LINE <br /> rSTTEEL <br /> wing 40-88 <br /> IST <br /> t� <br /> � 2.5 <br /> � - - - - -:- � , <br /> NEW ESFR PENDENT-,--," Snohomish County FUQ <br /> s Operations Center %Ir <br /> ROOF OPENING <br /> BOTTOM CHORD <br /> q BELOW UNIT 12"RETAINER STRAP OF BAR JOIST <br /> • 3/8"ANVIL92 <br /> TOP BEAM CLAMP 1 tyll e <br /> S 3/8.ATR <br /> D <br /> - L <br /> 2.5 <br /> o O MT <br /> �r1! HANGER RING - C1 <br /> 1 <br /> 3 <br /> BUILDING SECTION DETAIL HANGER (TB) _ - -M <br /> NTS NTS N AREA MAP N SITE PLAN <br /> NTS NTS <br /> ABBREVIATIONS SYMBOL LEGEND SYMBOL LEGEND PIPE LEGEND FLEX LEGEND SPRINKLER LEGEND REVISIONS CONTRACT WITH r <br /> AFF ABOVE FINISHED FLOOR MAKE TYPE LEN NIPPLE BRKTSCRWONrY SYM MANUFACTURER S.I.N. TYPE MODEL Nmv NO. DATE BY REASON FOR REVISION WASHINGTON STATE SMITH FIRE SYSTEMS, INC. <br /> BOB BOTTOM OF BEAM 12 CENTERLINE OF PIPE TO REFERENCED NEW SPRINKLER PIPE KROLL KONSTRUCTION CERTIFICATE OF COMPETENCY L L <br /> NEW 1"PLUG EASY HI PER 48" 1/2" ACT NA EXISTING # -/-/-- -- -- 1 1 J J TAC MA,AVE EAST <br /> Boo BOTTOM OF DECK STRUCTURE IN INCHES FIRE PROTECTION SPRINKLER SYSTEMS <br /> BOJ BOTTOM of JOIST BOD EXISTING SPRINKLER PIPE EASY HI PERF. 60" 1/2" ACT NA 780 FLORIDA CENTRAL PKWY SUITE 300 TACOMA,WA 9ITHF <br /> BOP BOTTOM OF TPURLIN <br /> RUSS 2-WAY EARTHQUAKE SWAY BRACE NEW 1/2"PLUG - - RELOCATED EXISTING PIPE EASY HI PERF. 72" 1/2" ACT NA 1 1 <br /> BOT BOTTOM OF TRUSS BUILDING INFORMATION LONGWOOD,FL 32750 Bassione Sean Van Soest 880 REG.NO.253)9 6-235 <br /> PO CUT <br /> ULDO SUITDER LETTER INDICATES TYPE NEW FLEXDROP EASY HI PERF. 48" 1/2"z9" GWB TEK 1 1 Bus: (253)926-1880 FAX: (253)926-2350 <br /> PO FIELD ORDER MAINTENANCE CONTACT <br /> IFow INSIDE FACE OF WALL 4-WAY EARTHQUAKE SWAY BRACE S NEW STRAP OUTLET i�-�� EASY HI PERF. 60" 1/2"z9" GWB TEK 1 6027-0110-C Level 3 1 <br /> OFM OUTSIDE FACE OF WALL LETTER INDICATES TYPE RELOCATED EXISTING FLEX EASY HI PERF. 72" 1/2"x9" GWB TEK MAINTENANCE PHONE: 1 Smith Fire Systems, Inc. N 1 KDCI AMAZON RTU <br /> NAS NO AUTO.SPRINKLERS PROJECT MANAGER: JOSEPH BUONOPANE v <br /> UNO UNLESS NOTED OTHERWISE f HANGER LOCATION MT NEW MECHANICAL TEE OUTLET BRACKET LEGEND: NEW ALARM COMPANY: <br /> N.I.C. NOT INCONTnACT WALL LEGEND ACT=STANDARD OGSB BRACKET OO RELIABLE RA1914 ESFR JL-17 BRZ 16.8K 3/4' 155' -- 8 S OFFICE PHONE: 407-469-5171 1 MITHFS1360T <br /> TOE THREADONEENO ALARM PHONE: <br /> ELEVATION ABOVE REFERENCED GAB=T-BAR,TBS ENDS,AND OSSB CLAMP CELL PHONE: 973-703-0145 p <br /> DOE <br /> GROOVE ONE ENO � POINT IN FEET AND INCHES R RELOCATED EXISTING SPRINKLER EXISTING WALL ALARM CODE: I 1 6617 ASSOCIATED BLVD <br /> TBEfi THREAD BOTH ENDS HCB=T-BAR,HCB ENDS,AND OSSB CLAMP EMAIL: JOSEPH@KROLLKONSTRUCTION.COM / <br /> O HYDRAULIC CALCULATION NODE P EXISTING THREADED OUTLET NEW WALL TO CEILING 4'BAR=T-BAR,TBS ENDS,AND OSSB CLAMP ALARM PASSWORD: II EVERETT,WA <br /> SUPERINTENDENT: RONPEREZ Expires <br /> NEW FULL HEIGHT WALL TEK= 21/4"x1.5"TEK SCREW FIRE DEPARTMENT: <br /> FLEXIBLE COUPLING WDS= z#1 FIRE DEPT.PHONE: PHONE: 760-275-1242 1 12/31/24 1 <br /> (E) EXISTING SYSTEM COMPONENT NEW LOW WALL () Ox1.5"WOOD W EMAIL: RON@KROLLKONSTRUCTION.COM mature__ ____ STAMP <br /> _sm <br /> ___ DESIGNER PROJECT MGR DATE SHEET JOB NO. <br /> -� RIGID COUPLING C - - - - - - - 7 NEW SOFFIT WALL 90°x1/2"="L NIPPLE 6"LONG ERTIFI o c TA MIRANDA LANE L. 10/8/24 1 OF 1 NI24019 <br /> 9'k1/2"=9"LONG x 1/2"EXTENDED NIPPLE TOTAL NEW 9 <br />