Laserfiche WebLink
L City of Everett Permit Services PLAN SYMBOLS <br /> EVERETT Reviewed for Permit 03/05/2025 WIRING DIAGRAM SYMBOLS <br /> GROUNDING CONDUIT & WIRE CONT'D DATA / NETWORK CONTROLS/INSTRUMENTATION SINGLE LINE SINGLE LINE SCHEMATIC <br /> D CONDUIT TURNS DOWN TRANSFORMER (DASHED LINE 1 DISCONNECT SWITCH <br /> T GROUND CABLE CONNECTION 1# DATA OUTLET (# OF PORTS AS NOTED) AE ANALYTICAL ELEMENT (PH, ORP) o <br /> T GROUND ROD CONNECTION DATA / TELEPHONE OUTLET INDICATES D ELECTROSTATIC FUSED SWITCH FUSE <br /> � CONDUIT TURNS UP AT ANALYTICAL TRANSMITTER (PH, ORP) = CIRCUIT BREAKER <br /> 0 DATA POWER POLE <br /> GROUND CABLE PIGTAIL MAFS CONDUIT SEAL D© DATA CABINET, CHATSWORTH FLOW SWITCH SURGE ARRESTER� � U�j <br /> �-G- GROUND CABLE (UNDERGROUND) ® ACCESS CONTROL PANEL FLOW TRANSMITTER - / M.V. DISCONNECT SWITCH (� TRANSFORMER <br /> EQUIPMENT/STRUCTURAL GROUND CONNECTION CABLE TRAY ® CCTV MEDIA CONVERTER ENCLOSURE r (NF OPTION) <br /> 360 DEGREE PTZ CAMERA LS LEVEL SWITCH T CIRCUIT BREAKER �LI L.V. DISCONNECT SWITCH - GROUND CONNECTION <br /> POWER POWER RECEPTACLES LT LEVEL TRANSMITTER / (DRAW-OUT TYPE) 6O NF(NON FUSED) <br /> PILOT LIGHT <br /> 0 PANELBOARD, 208Y/120V, 3 PHASE REMOVAL Y SWITCH RATING / * INDICATES COLOR <br /> k� 120V, 15A, 1 PHASE, 2 POLE, 3 WIRE //// MOTORIZED VALVE INTERLOCK <br /> ® PANELBOARD, 480V OR 480Y/277V, 3 PHASE RECEPTACLE, NEMA 5-15R, HUBBELL #5262 171L{7T� CONDUIT TO BE REMOVED K=KEY PUSHBUTTON <br /> EQUIPMENT IDENTIFICATION ffi 120V, 15A, 1 PHASE, 2 POLE, 3 WIRE, PS PRESSURE SWITCH K M=MECHANICAL __0 o- MOMENTARY CONTACT <br /> 'T DENOTES EQUIPMENT NUMBER DUPLEX CORD DROP RECEPTACLE, NEMA 5-15R, EQUIPMENT OR MATERIALS TO POTENTIAL TRANSFORMER E=ELECTRICAL NORMALLY OPEN <br /> "Y" DENOTES HP OR AMPS HUBBELL #5262 U0� BE DISCONNECTED AND REMOVED PT PRESSURE TRANSMITTER 2 480:120 QUANTITY & RATIO <br /> Ir AS SHOWN PUSHBUTTON <br /> C� SPECIAL PANELBOARD/ENCLOSURE (TYPE AS NOTED) pg 20 120V, 20A, 1 PHASE, 2 POLE, 3 WIRE, SV SOLENOID VALVE XX FEEDER TYPE �� MOMENTARY CONTACT <br /> 0' ® ENCLOSED CIRCUIT BREAKER DISCONNECT RECEPTACLE, NEMA 5-20R, HUBBELL #5362 LIGHTING 3 800:5 CURRENT TRANSFORMER O DESIGNATION NORMALLY CLOSED <br /> (SIZE AS NOTED) 30 120V, 30A, 1 PHASE, 2 POLE, 3 WIRE, TWISTLOCK LIGHT FIXTURE - SHADED TE TEMPERATURE ELEMENT (RTD, TIC) QUANTITY & RATIO <br /> RECEPTACLE, NEMA L5-30R, HUBBELL #2610A © CONNECTED TO EMERGENCY CIRCUIT AS SHOWN AVAILABLE FAULT OFF ON SELECTOR SWITCH <br /> ® VARIABLE SPEED MOTOR STARTER TS TEMPERATURE SWITCH XXX XXX CURRENT (CLOSED MAINTAINED CONTACT <br /> p 120V, 15A, 1 PHASE, 2 POLE, 3 WIRE EXIT SIGN, WALL MOUNTED. DIRECTIONAL A AS AMMETER w/SWITCH TRANSITION/NORMAL) TWO POSITION <br /> ® SOLID STATE MOTOR STARTER DOUBLE DUPLEX RECEPTACLE, NEMA 5-15R, ARROW SHOWN ❑TT TEMPERATURE TRANSMITTER 2 <br /> HUBBELL #5262 �/ VS VOLTMETER w/SWITCH XXX XXX EQUIPMENT AIC RATING 1 1�3 <br /> ❑' DISCONNECT SWITCH (FUSED OR UNFUSED) ®+ EXIT SIGN, CEILING MOUNTED. DIRECTIONAL �TT <br /> 30/20 SWITCH RATING/FUSE RATINGSHOWNZS POSITION SWITCH J l SELECTOR SWITCH <br /> M 30 208V, 30A, 3 PHASE, 4 WIRE, 4 POLE GROUND ARROW �� <br /> a MAGNETIC MOTOR STARTER COMBINATION THRU SHEEVE STYLE 1 . CROUSE HINDS *XXX APPROXIMATE FEEDER MAINTAINED CONTACT <br /> (COMBINATION) ( ) e FIXTURE IDENTIFICATION HM WATTHOUR METER -+-2 THREE POSITION <br /> #ARE3412 "X" DENOTES FIXTURE TYPE LENGTH IN FEET TO �1� <br /> ® MANUAL MOTOR STARTER Y BE CONFIRMED LATER. 3 <br /> o 30 208V, 30A, 1 PHASE, 2 WIRE, 3 POLE, 'Y" DENOTES WATTAGE OF FIXTURE <br /> CORD DROP WITH TWISTLOCK, NEMA L6-30R, ® 480V OR 480Y/277V SOLENOID VALVE <br /> ❑T TRANSFORMER (SIZE AS SHOWN, IN KVA) HUBBELL #2623 a E19-1 PANELBOARD <br /> O JUNCTION BOX �-BRANCH CIRCUIT NUMBER 400 A (RATINGS AS <br /> k� 480V, 30A, 3 PHASE, 4 POLE, 3 WIRE GROUND M. BKR. NOTED) PRESSURE SWITCH - N.C. <br /> ❑O ESTOP SWITCH - MAINTAINED 30 THROUGH EXTRA POLE. CROUSE HINDS #ARE 3423 SWITCH IDENTIFICATION 3 PH, 4 W OPENS ON RISING PRESSURE <br /> El PULL BOX $3 LIGHTING CONTROL SWITCH, 3 WAY <br /> p� #WP 15A, 125V, DUPLEX IN A WEATHERPROOF ENCLOSURE GE RS237 PRESSURE SWITCH - N.O. <br /> ® HAND HOLE 208V OR 208Y/120V CLOSES ON RISING PRESSURE <br /> (NEMA 3R RAINTIGHT) CLASS 1 DIVISION 2: E19-3 PANELBOARD <br /> © MAN HOLE LARSON #EPS-25A-3W 225 A (RATINGS AS <br /> ® OFF ON SELECTOR SWITCH CONTROL STATION �GFI 125V, DUPLEX WITH BUILT IN GROUND FAULT M. BKR. NOTED) FLOAT OR LEVEL SWITCH - N.C. <br /> / CIRCUIT INTERRUPTER, HUBBELL GF52621 ® OCCUPANCY SENSOR, LOW VOLTAGE � OPENS ON RISING LEVEL <br /> a 3 PH, 4 W <br /> Q STOP-START PUSHBUTTONGE #CDT-20-360-R CONTROL STATION FLOOR BOX WITH 20A 120V FOURPLEX AND CLASS 1 DIVISION 1: <br /> ® DATA COMPARTMENT CARBON #EXP-MS-N4X-AT-LV-V7 � FLOAT OR LEVEL SWITCH - N.O. <br /> OO 460 VOLT MOTOR (SIZE AS NOTED) COMBINATION STARTER VFD CLOSES ON RISING LEVEL <br /> 4 208 VOLT OR 240 V MOTOR HP� 208V, 20A, 1 PHASE, 2 POLE, 3 WIRE, TWISTLOCK ® DAYLIGHT PHOTOCELL, LOW VOLTAGE CONTROLLER OR MCC v FLOW SWITCH - N.C. <br /> (SIZE AS NOTED) RECEPTACLE, NEMA L6-30R, HUBBELL #2320A GE #PCD-IN 3A CUBICLE NUMBER OPENS ON INCREASE IN FLOW <br /> 115 VOLT MOTOR (SIZE AS NOTED) 50� NEMA 14-50R STRAIGHT BLADE, 120/208V, FL-C-PTI LIGHTING CONTROL PANEL 77 <br /> © CONTACTOR 10, 3-POLE, 4-WIRE RECEPTACLE, 50A. I T1 FLOW SWITCH - N.O. <br /> $ RCP RECEPTACLE CONTROL PANEL \ OR 6 / CLOSES ON INCREASE IN FLOW <br /> T MECHANICAL TIMER SWITCH FIRE DETECTION J <br /> ® SOLENOID VALVES RECESSED LED DOWNLIGHT VFD TEMPERATURE SWITCH - N.C. <br /> CORD REEL FFTC`P1 FIRE ALARM CONTROL PANEL HIGH BAY FIXTURE <br /> 2 <br /> CONDUIT & WIRE FAA FIRE ALARM ANNUNCIATION PANEL STARTER SIZE OPENS ON RISING TEMP <br /> TEMPERATURE SWITCH - N.O. <br /> MANUAL PULL STATION O LB LOW BAY FIXTURE CLOSES ON RISING TEMP <br /> CONDUIT SURFACE MOUNTED OR CONCEALED. ❑F HZ MANUAL PULL STATION (HAZARDOUS LOC. RATED) ® RECESSED 2'X4' FIXTURE POWER FACTOR �� <br /> CORRECTION CAPACITOR LIMIT SWITCH - N.C. <br /> -E- CONDUIT IN WALL OR CEILING SPACE. ®Q HORN WITH STROBE RECESSED 2'X2' FIXTURE (IF REQUIRED) <br /> CONTAINS ONE AWG #12 PHASE, AND ONE <br /> AWG #12 NEUTRAL CONDUCTOR UNLESS LIMIT SWITCH - N.O. <br /> OTHERWISE NOTED. "E" INDICATES � HIGH VOLUME HORN/STROBE CLUSTER ® STRIP LIGHT FIXTURE 1--, H P � MOTOR HORSEPOWER H P �� <br /> RELAYS & COILS <br /> EMERGENCY CIRCUIT. * <br /> ® STRIP LIGHT FIXTURE, CLASS 1, DIV. 2, I� *=TYPE <br /> ------- STROBE ONLY CONDUIT UNDERGROUND, UNDER FLOOR SLAB, ❑1 HORN ONLY (HAZARDOUS LOC. RATED) DIALIGHT LKU-5MN2-7DNN-NGN OR EQUAL THERMO MAGNETIC CIRCUIT BREAKER <br /> OR IN CEILING SPACE OF FLOOR BELOW WITH HZ M=MOTOR STARTER <br /> CONDUCTORS AS ABOVE. ❑/ HIGH VOLUME HORN (HAZARDOUS LOC. RATED) CR=CONTROL RELAY <br /> HZ HD C=CONTACTOR <br /> CONDUIT ONLY. M WALL PACK TR=TIME DELAY OR TIMING <br /> ®HZ STROBE ONLY (HAZARDOUS LOC. RATED)� MAGNETIC ONLY CIRCUIT BREAKER RELAY O• EMERGENCY WALL FLOOD LIGHT, DIALIGHT CMD OR EQUAL I <br /> FLEXIBLE METAL CONDUIT. PROVIDE CIRCUIT 0 THERMAL SENSOR N.O. CONTACT <br /> CONDUCTCONDU U RED BASED ON 60 DEGREE OHZ THERMAL SENSOR (HAZARDOUS LOC. RATED) <br /> CONTROL PANELS �� N.C. CONTACT <br /> INDICATES PHASE CONDUCTOR <br /> I ALARM INPUT MODULE <br /> (#12 OR SIZE AS NOTED) ® ALARM OUTPUT MODULE - -&- PANEL TERMINAL WITH NUMBER N.O. - ON DELAY CONTACT <br /> INDICATES NEUTRAL CONDUCTOR 851-555 <br /> S SMOKE DETECTOR PANEL WIRING WITH WIRE NUMBER <br /> (#12 OR SIZE AS NOTED) N.C. - ON DELAY CONTACT <br /> INDICATES GROUND CONDUCTOR /� 851=666 <br /> (#12 OR SIZE AS NOTED) \� DUCT SMOKE DETECTOR FIELD WIRING WITH WIRE NUMBER <br /> INDICATES ISOLATED GREEN GROUND CONDUCTOR ❑6 REMOTE TEST STATION WITH KEY ® TERMINAL IN MCC �� N.O. - OFF DELAY CONTACT <br /> (#12 OR SIZE AS NOTED) IF­S1 FLOW SWITCH <br /> ® TERMINAL IN PLC CONTROL PANEL <br /> HOMERUN W/7#10 SHOWING CIRCUIT rS PRESSURE SWITCH N.C. - OFF DELAY CONTACT <br /> #1 � SOURCE (PANEL/PANEL POSITION) © TAMPER SWITCH ❑ REMOTE TERMINAL FIELD <br /> iD6-1/1,3,5,7 ® END OF LINE RESISTOR O PANEL DEVICE TERMINAL <br /> HOMERUN W/CIRCUIT SOURCE & CONDUIT & © END OF LINE CAPACITOR 90% REVIEW ❑ CONTROL PANEL TERMINAL Kennedy/Jenks Consultants <br /> 1B2-8/1,3,5 WIRE SIZE NOTED <br /> 1-1/2"C,3#2+#2/ON+2#8G ^ / ^ O FLEX I/O TERMINAL 3200132nd Avenue South, <br /> Way,WA <br /> 0-/" 0 /5 Federal Way,WA 98007 <br /> L I L ��� FUSE Ph.253-835-6400 <br /> Fax 253.952.3435 <br /> SYM REVISION BY APPROVED DATE $YM REVISION By APPROVED DATE D DATEg D SUBTm_E CURREM C238185 BOLO R I DATE 02.1 Q.25 <br /> y C- ACCEPTABILITY Z.DEVLIN oz.lo.zs ELECTRICAL LEGEND AND SYMBOLS <br /> ISYM <br /> ORIG 100%FINAL DESIGN-ISSUED FOR CONSTRUCTION C236185 KJ ZCD 02.10.25 �iQ' cf'p THIS DESIGN AND B. DOCKTOR 02.10.25 SHEET <br /> G � SPECIFlCATION IS APPROVED <br /> BOE//VG® Z APPROVED BY DFPi' oA7E Z.DEVLIN 02.10.25 E 1 <br /> CHECKED I <br /> J. MOHR 02.10.25 <br /> APPROVED BUILDING 40-09 58 2 JOB N0. C2381 SS COMP N0. <br /> �, APPROVED ELECTRICAL COL. X-X/X-X EVERETT, WA DM No. 40-009-El <br />