Laserfiche WebLink
L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 03/05/2025 <br /> BUILDING CODE SUMMARY CODE SUMMARY <br /> 40-009 SEWER METER CONSTRUCTION TYPE TYPE II-B,PER IBC 602.2, APPLICABLE CODES: <br /> BUILDING SINGLE STORY INSULATED PRE-ENGINEERED METAL BUILDING,SLAB-ON-GRADE <br /> FLOOR. TITLE 16 EVERETT MUNICIPAL CODE <br /> STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2021 EDITION OF THE <br /> BUILDING ELEMENT FIRE RESISTANCE 0-HOUR RATING AS PER IBC TABLE 601 FOR TYPE II B CONSTRUCTION INTERNATIONAL BUILDING CODE,CHAPTER 51-50 WAC,ADOPTED. <br /> EXTERIOR WALL FIRE RESISTANCE(BASED ON 0-HOUR RATING AS PER IBC TABLE 602 FOR TYPE II B CONSTRUCTION; STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2021 EDITION OF THE <br /> SEPARATION DISTANCE) INTERNATIONAL FIRE CODE,CHAPTER 51-54A,ADOPTED. <br /> ALLOWABLE AREA 15,500 SF PER IBC TABLE 506.2 STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2021 EDITION OF THE UNIFORM <br /> PLUMBING CODE,CHAPTER 51-56 WAC,ADOPTED. <br /> ACTUAL AREA 350 SF <br /> STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2021 EDITION OF THE <br /> ALLOWABLE HEIGHT 55'-0-FEET 2-STORY PER IBC TABLES 504.3 AND 504.4 INTERNATIONAL MECHANICAL CODE,CHAPTER 51-52 WAC,ADOPTED. <br /> ACTUAL HEIGHT/STORY 9'-0"f FEET/ 1-STORY STATE BUILDING CODE ADOPTION AND AMENDMENT OF THE 2021 EDITION OF THE <br /> OCCUPANCY CLASSIFICATIONS FLOWMETER ROOM: F-1 MODERATE HAZARD FACTORY INDUSTRIAL PER IBC 306.2 INTERNATIONAL ENERGY CONSERVATION CODE,COMMERCIAL PROVISIONS,CHAPTER 51-11C <br /> WAC,ADOPTED. <br /> OCCUPANCY SEPARATIONS NOT APPLICABLE 2023 NEC(NFPA 70-2023)PER WAC 296-46B-010 GENERAL,ADOPTED. <br /> • NFPA 820-STANDARD FOR FIRE PROTECTION IN WASTEWATER TREATMENT AND <br /> OCCUPANT LOAD 2 PER IBC TABLE 1004.5 COLLECTION FACILITIES <br /> FLOWMETER ROOM(350 S.F.) 2 OCCUPANTS(1 EXIT RED./ 1 ACTUAL PER IBC SECTION 1006.2.1) 2025 WASHINGTON STATE OSHA REGULATIONS <br /> (MECHANICAL EQUIPMENT ROOM) <br /> MAXIMUM PATH OF EGRESS TRAVEL 75 FEET PER IBC TABLE 1006.2.1 <br /> WAC UNCONDITIONED JURISDICTION: <br /> VENTILATION ACTUAL- 12 ACH FOR UNCLASSIFIED SPACE PER NFPA 820 TABLE 4.2.2-ROW 34b <br /> ENERGY CODE CITY OF EVERETT <br /> EVERETT,NOT APPLICABLE-UNCONDITIONED EXISTING MECHANICAL ROOM EVER WETT,,W WA AVENUE <br /> EA 98201 <br /> ACCESSIBILITY NOT REQUIRED PER IBC SECTION 1103.2.9 <br /> CHEMICAL STORAGE NONE <br /> SPRINKLER SYSTEM NOT REQUIRED PER IBC SECTION 903.2.4 <br /> SMOKE DETECTION NOT REQUIRED PER IBC SECTION 907.2.4 <br /> SMOKE AND HEAT VENTS NOT REQUIRED PER IBC SECTION 910.2.1 <br /> FIRE ALARM NOT REQUIRED PER IBC SECTION 907.2.4 <br /> FIRE PROTECTION REQUIREMENTS(IFC) HYDRANT PROTECTION WITHIN 250'OF STRUCTURE PER IFC TABLE C102.1 <br /> FIRE FLOW(IFC) 1,500 GPM FOR 2 HOURS PER IFC TABLE B105.1.(2) <br /> A <br /> 90% REVIEW Kennedy/Jenks Consultants <br /> O/1• A �1 •/1 32001 32nd Avenue South,Suite 101 <br /> L �I -I L Federal Way,WA 98007 <br /> Ph.253-835-6400 <br /> Fax 253.952.3435 <br /> ACCEPTABILITY B. HOFFER 02.11.25 DRAWN DATESUSTM-E CURRENT C238185 EVISIONsvMeoL A DATE D2.11.25 <br /> sM REN310N R APPROVED DATE BYM REVISION �^� 4455 BUILDING CODE SUMMARY <br /> ORIG 100%FINAL DESIGN—ISSUED FOR CONSTRUCTION C238185 KJ JEA 09.25.23 ,w` REGISTERED THIS DESIGN AND/OR — — <br /> ' 7 ARCHITECT SPECIFICATION IS APPROVED ME SHEEP �� <br /> A SEWER METER BYPASS(PHASE 1) C238185 KJ JEA 02.11.25BOE/NG® APPROVED BY DEPT. DATE M. PRE IN 02.11.25 <br /> MARK PRESTON CHECKED <br /> STALE OF WASHINGTON APPROVED BUILDING 40-09 JOB NO. C238185 COMP NO. <br /> APPROVED ARCHITECTURAL MASTER COL. X-X/X-X EVERETT. WA 11 No. 40-09-A3 <br />